Current estimation method at the time of a contact wire breakage during standstill below insulated overlap based on contact wire necking length

被引:0
|
作者
Wada S. [1 ]
Ito K. [2 ]
Hayasaka T. [1 ]
机构
[1] Wada, Shogo
[2] Ito, Kazuhiko
[3] Hayasaka, Takamasa
来源
| 1600年 / Ken-yusha Inc.卷 / 61期
关键词
Arc; Breaking of wire; Contact wire; DC electric railways; Insulated overlap;
D O I
10.2219/rtriqr.61.1_34
中图分类号
学科分类号
摘要
One of the critical points in the DC feeding system is the insulated overlap. In the insulated overlap, the contact wire breakage accident during standstill sometimes occurred. It is caused by joule heat due to the current flowing between the contact wire and the contact strip, through the arc due to poor contact condition. To understand the phenomenon of this kind of accident and to take countermeasures against it, it is important to evaluate the current that flows through breakage point. However, since the current is affected by the other train load current, it is difficult to estimate it based on the recorded data of the substation. Once the contact wire is softened, its mechanical strength decreases resulting in breakage due to tension force. The authors conducted wire break tests focusing on the arc. As a result, it has been found that the necking of the contact wire at the point of the breakage caused by the arc depends on the arc current and tension of the contact wire. In this study, the relationship between the arc current, the tension of the contact wire, and the necking length of the contact wire was investigated through the tests conducted under the condition where the arc current was set from about 30 A to 300 A under the tension of 9.8 kN or 19.6 kN. Then we proposed a method of estimating the current of the contact wire at the time of its breakage accident during standstill in the insulated overlap section based on the necking length of the contact wire. © 2019 WIT Press.
引用
收藏
页码:34 / 39
页数:5
相关论文
共 26 条
  • [21] Influence of Apparent Contact Area on Wear Properties of Hard-Drawn Copper Contact Wire and Iron-Based Sintered Alloy Contact Strip under Electric Current Flowing Condition
    Yamashita, Chikara
    Adachi, Koshi
    TRIBOLOGY ONLINE, 2019, 14 (02): : 102 - 108
  • [22] Full contact analysis of wire rope strand subjected to varying loads based on semi-analytical method
    Chen, Yuanpei
    Meng, Fanming
    Gong, Xiansheng
    INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 2017, 117 : 51 - 66
  • [23] A mechanics principle based inverse technique for real-time monitoring of wear-level of contact wire in pantograph-catenary systems
    Xu, F. T.
    Duan, S. Y.
    Wang, F.
    Liu, G. R.
    APPLIED MATHEMATICS IN SCIENCE AND ENGINEERING, 2022, 30 (01): : 75 - 93
  • [24] Contact wire position measurement on trolley-based system using 3D Laser-Scanning with geometric constraint method
    Wu, Xueqin
    Ma, Jian
    Wang, Jianfeng
    Song, Hongxun
    Xu, Jiyang
    MEASUREMENT, 2023, 221
  • [25] Non-contact method for the accurate estimation of the full-length of Takifugu rubripes based on 3D pose fitting
    Zhou J.
    Ji B.
    Ni W.
    Zhao J.
    Zhu S.
    Ye Z.
    Nongye Gongcheng Xuebao/Transactions of the Chinese Society of Agricultural Engineering, 2023, 39 (04): : 154 - 161
  • [26] A marker based kinematic method of identifying initial contact during gait suitable for use in real-time visual feedback applications
    De Asha, A. R.
    Robinson, M. A.
    Barton, G. J.
    GAIT & POSTURE, 2012, 36 (03) : 650 - 652