摘要
The concrete moisture content must be maintained after curing. The cement particles in concrete cannot fully hydrate and transform to a stable crystalline form if the concrete is not well hydrated. In addition, moisture loss may result in shrinkage, deformation and cracks, which will affect the structure durability. Concrete specifications and experience have shown that the concrete surface humidity should be no less than 95% during curing. Humidity diffusion theory was used to develop a mathematical model for the concrete moisture conservation with the third type of boundary condition at the surface. Information technology and mechanical control theory were then used to develop an intelligent control method for the concrete moisture conservation. An intelligent control system was then developed to automatically collect the temperature, humidity and wind speed near the concrete surface and to then calculate the concrete surface humidity. The intelligent control system provides real-time feedback warnings and intelligently controls a spray tube which reduces labor costs and ensures the concrete quality. The intelligent control equipment can be flexibly adapted to various large, complex engineering projects. © 2021, Tsinghua University Press. All right reserved.
引用
收藏
页码:671 / 680
页数:9
相关论文
共 45 条
  • [31] Code for construction of concrete structures: GB50666-2011, (2011)
  • [32] Standard for test method of mechanical properties on ordinary concrete: GB/T50081-2002, (2002)
  • [33] MA W B, LI G., Study on the temperature and humidity response of concrete in natural climate, Concrete and cement products, 2, pp. 18-21, (2007)
  • [34] WEISS W J., Prediction of early-age shrinkage cracking in concrete, (1999)
  • [35] PARROTT L J., Moisture profiles in drying concrete, Advances in Cement Research, 1, 3, pp. 164-170, (1998)
  • [36] PARROTT L J., Factors influencing relative humidity in concrete, Magazine of Concrete Research, 43, 154, pp. 45-52, (1991)
  • [37] ZHU B F., Temperature stress and temperature control of mass concrete, (2012)
  • [38] Committee Euro-international du Beton/Federation International de la Precon-strainte, CEB-FIP model code for concrete structures, (1990)
  • [39] PENG Z, JIN N G, JIN X Y., Theoretical modeling and verification of concrete moisture diffusion surface factor, Journal of Zhejiang University (Engineering Science), 44, 10, pp. 2010-2015, (2010)
  • [40] DUAN Y H, FAN Q X, DUAN C Y., Real time control method of concrete spray moisturizing curing process in complex environment