A wearable microneedle patch incorporating reversible FRET-based hydrogel sensors for continuous glucose monitoring

被引:0
|
作者
Hu, Yubing [1 ]
Pan, Zhisheng [1 ]
De Bock, Marieke [2 ]
Tan, Tai Xuan [1 ]
Wang, Yuhuai [3 ]
Shi, Yuqi [1 ]
Yan, Neng [3 ]
Yetisen, Ali K. [1 ]
机构
[1] Department of Chemical Engineering, Imperial College London, London,SW7 2AZ, United Kingdom
[2] Department of Chemical Engineering, Massachusetts Institute of Technology, Cambridge,MA,02139, United States
[3] State Environmental Protection Key Laboratory of Source Apportionment and Control of Aquatic Pollution, School of Environmental Studies, China University of Geosciences, Wuhan,430074, China
基金
英国工程与自然科学研究理事会;
关键词
Energy transfer - Ethylene - Ethylene glycol - Forster resonance energy transfer - Glucose sensors - Hydrogels - Photobleaching - Photopolymerization - Physiological models - Wearable sensors;
D O I
10.1016/j.bios.2024.116542
中图分类号
学科分类号
摘要
Continuous glucose monitors are crucial for diabetes management, but invasive sampling, signal drift and frequent calibrations restrict their widespread usage. Microneedle sensors are emerging as a minimally-invasive platform for real-time monitoring of clinical parameters in interstitial fluid. Herein, a painless and flexible microneedle sensing patch is constructed by a mechanically-strong microneedle base and a thin layer of fluorescent hydrogel sensor for on-site, accurate, and continuous glucose monitoring. The Förster resonance energy transfer (FRET)-based hydrogel sensors are fabricated by facile photopolymerizations of acryloylated FRET pairs and glucose-specific phenylboronic acid. The optimized hydrogel sensor enables quantification of glucose with reversibility, high selectivity, and signal stability against photobleaching. Poly (ethylene glycol diacrylate)-co-polyacrylamide hydrogel is utilized as the microneedle base, facilitating effective skin piercing and biofluid extraction. The integrated microneedle sensor patch displays a sensitivity of 0.029 mM−1 in the (patho)physiological range, a low detection limit of 0.193 mM, and a response time of 7.7 min in human serum. Hypoglycemia, euglycemia and hyperglycemia are continuously monitored over 6 h simulated meal and rest activities in a porcine skin model. This microneedle sensor with high transdermal analytical performance offers a powerful tool for continuous diabetes monitoring at point-of-care settings. © 2024 The Authors
引用
收藏
相关论文
共 50 条
  • [1] Wearable transdermal microneedle patch based on photonic crystal hydrogel for glucose monitoring
    Zhang, Ping-Ping
    Zhu, Jia-Cheng
    Zhao, Bo-Jun
    Xu, Sheng-Hao
    Wang, Lei
    Luo, Xi-Liang
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2022, 50 (04)
  • [2] FRET-based glucose monitoring for bioprocessing
    Bartolome, Amelita
    Smalls-Mantey, Lauren
    Lin, Debora
    Rao, Govind
    Tolosa, Leah
    [J]. GENETICALLY ENGINEERED PROBES FOR BIOMEDICAL APPLICATIONS, 2006, 6098
  • [3] Continuous Ketone Monitoring via Wearable Microneedle Patch Platform
    Moonla, Chochanon
    Reynoso, Maria
    Casanova, Ana
    Chang, An-Yi
    Djassemi, Omeed
    Balaje, Aishwarya
    Abbas, Amal
    Li, Zhengxing
    Mahato, Kuldeep
    Wang, Joseph
    [J]. ACS SENSORS, 2024, 9 (02) : 1004 - 1013
  • [4] Towards a FRET-based immunosensor for continuous carbohydrate monitoring
    Engstrom, Henrik A.
    Andersson, Per Ola
    Gregorius, Klaus
    Ohlson, Sten
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 2008, 333 (1-2) : 107 - 114
  • [5] FRET-based genetically-encoded sensors for quantitative monitoring of metabolites
    Mohd. Mohsin
    Altaf Ahmad
    Muhammad Iqbal
    [J]. Biotechnology Letters, 2015, 37 : 1919 - 1928
  • [6] FRET-based genetically-encoded sensors for quantitative monitoring of metabolites
    Mohsin, Mohd.
    Ahmad, Altaf
    Iqbal, Muhammad
    [J]. BIOTECHNOLOGY LETTERS, 2015, 37 (10) : 1919 - 1928
  • [7] Impedance-based polymer microneedle patch sensor for continuous interstitial fluid glucose monitoring
    Piao, Honglin
    Choi, Yong-Ho
    Kim, Jaehyun
    Park, Daerl
    Lee, Jia
    Khang, Dahl-Young
    Choi, Heon-Jin
    [J]. BIOSENSORS & BIOELECTRONICS, 2024, 247
  • [8] An integrated wearable differential microneedle array for continuous glucose monitoring in interstitial fluids
    Yang, Yong
    Sheng, Can
    Dong, Fang
    Liu, Sheng
    [J]. BIOSENSORS & BIOELECTRONICS, 2024, 256
  • [9] Wearable Continuous Glucose Monitoring Sensors: A Revolution in Diabetes Treatment
    Cappon, Giacomo
    Acciaroli, Giada
    Vettoretti, Martina
    Facchinetti, Andrea
    Sparacino, Giovanni
    [J]. ELECTRONICS, 2017, 6 (03):
  • [10] Colorimetric sweat analysis using wearable hydrogel patch sensors for detection of chloride and glucose
    Li, Tuqiang
    Chen, Xiaofeng
    Fu, Ying
    Liao, Caizhi
    [J]. ANALYTICAL METHODS, 2023, 15 (43) : 5855 - 5866