Electrochemical detection of copper ions with covalent organic frame material modified carbon paste electrode

被引:0
|
作者
Xin, Yu [1 ,2 ,3 ]
Liu, Xiangju [1 ,3 ]
Wang, Chunli [3 ,4 ]
Liu, Nazhen [1 ,3 ]
Jiang, Quantong [1 ,3 ]
Duan, Jizhou [1 ,3 ]
机构
[1] Key Laboratory of Marine Environment Corrosion and Bio-Fouling, Institute of Oceanology, Chinese Academy of Sciences, Qingdao,266071, China
[2] University of Chinese Academy of Sciences, Beijing,100049, China
[3] Open Studio for Marine Corrosion and Protection, Pilot National Laboratory for Marine Science and Technology (Qingdao), Qingdao,266237, China
[4] Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Shenyang,110819, China
关键词
Carbon - Chemical detection - Copper - Cyclic voltammetry - Electrochemical electrodes - Fourier transform infrared spectroscopy - Ionic liquids - Metal ions - Molar ratio;
D O I
10.13595/j.cnki.issn1000-0720.2022.070402
中图分类号
学科分类号
摘要
The covalent organic framework material TpBD-COF was synthesized by solvothermal reaction, and characterized using scanning electron microscopy and Fourier transform infrared spectroscopy. Then, COF-2-BPPF6-CPE was prepared by mixing TpBD-COF,carbon paste and ionic liquid [BPPF6] in a certain proportion, and the electrochemical performance of the working electrode was evaluated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). Copper ions can be sensitively responded on the modified electrode in a buffer solution of potassium hydrogen phthalate at pH 3.50. The results showed that the COF modified carbon paste electrode had higher peak current for copper ion, and the peak current was linearly related to the molar concentration of copper ion in the range of 1 to 200 μmol/L,with a linear correlation coefficient(R2) of 0.9997. The detection limit was 0.13 μmol/L. The modified electrode showed excellent selectivity, stability and reproducibility. The standard addition method was used for the determination of copper ions in water samples with recoveries in the range of 100.6%-101.2%. These results suggested that COF modified carbon paste electrodes can be applied to detect copper ions in water samples. © 2023 the authors.
引用
收藏
页码:1199 / 1204
相关论文
共 50 条
  • [41] Synthesis of phosphate-modified zeolite as a modifier in carbon paste electrode for nitrite electrochemical detection
    Idris, Adamu
    Saleh, Tawfik
    Muraza, Oki
    Sanhoob, Mohammed
    Aziz, Md. Abdul
    Al-Betar, Abdul-Rahman
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2019, 30 (04) : 3283 - 3293
  • [42] Direct Electrochemical Detection of Trace Porcine Insulin on Carbon Paste Electrode with Modified Graphite Powder
    Guo, C. Z.
    Chen, C. G.
    Luo, Z. L.
    Zhao, A. D.
    [J]. ASIAN JOURNAL OF CHEMISTRY, 2012, 24 (08) : 3665 - 3670
  • [43] ZnO@MnO2 nanocomposite modified carbon paste electrode for electrochemical detection of dopamine
    Anantha M.S.
    Kiran Kumar S.R.
    Anarghya D.
    Venkatesh K.
    Santosh M.S.
    Yogesh Kumar K.
    Muralidhara H.B.
    [J]. Sensors International, 2021, 2
  • [44] Comparative investigation on electrochemical behavior of hydroquinone at carbon ionic liquid electrode, ionic liquid modified carbon paste electrode and carbon paste electrode
    Zhang, Ya
    Zheng, Jian Bin
    [J]. ELECTROCHIMICA ACTA, 2007, 52 (25) : 7210 - 7216
  • [45] A reliable electrochemical sensor for detection of catechol and hydroquinone at MgO/GO modified carbon paste electrode
    K. Chetankumar
    B. E. Kumara Swamy
    T. S. Sunil Kumar Naik
    [J]. Journal of Materials Science: Materials in Electronics, 2020, 31 : 19728 - 19740
  • [46] A reliable electrochemical sensor for detection of catechol and hydroquinone at MgO/GO modified carbon paste electrode
    Chetankumar, K.
    Swamy, B. E. Kumara
    Naik, T. S. Sunil Kumar
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2020, 31 (22) : 19728 - 19740
  • [47] Synthesis of phosphate-modified zeolite as a modifier in carbon paste electrode for nitrite electrochemical detection
    Adamu Idris
    Tawfik Saleh
    Oki Muraza
    Mohammed Sanhoob
    Md. Abdul Aziz
    Abdul-Rahman Al-Betar
    [J]. Journal of Materials Science: Materials in Electronics, 2019, 30 : 3283 - 3293
  • [48] A nickel porphyrin-based covalent organic framework modified electrode for the electrochemical detection of acetaminophen
    Hou, Lu
    Jiang, Yue
    Chen, Li-Zhen
    Zhang, Sheng-Feng
    Li, Heng-Ye
    Wei, Mei-Jie
    Kong, Fen-Ying
    Wang, Wei
    [J]. Analytical Methods, 2024, 16 (45) : 7789 - 7794
  • [49] Electrochemical behavior and detection of guanine using a sodium montmorillonite-modified carbon paste electrode
    W. Huang
    S. Zhang
    Y. Wu
    [J]. Russian Journal of Electrochemistry, 2006, 42 : 153 - 156
  • [50] 2-Mercaptobenzothiazole modified carbon paste electrode as a novel copper sensor: An electrochemical and computational study
    Flores-Alvarez, J. M.
    Cortes-Arriagada, D.
    Reyes-Gomez, J.
    Gomez-Sandoval, Z.
    Rojas Montes, J. C.
    Pineda-Urbina, K.
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2021, 888