Electrochemical detection of copper ions with covalent organic frame material modified carbon paste electrode

被引:0
|
作者
Xin, Yu [1 ,2 ,3 ]
Liu, Xiangju [1 ,3 ]
Wang, Chunli [3 ,4 ]
Liu, Nazhen [1 ,3 ]
Jiang, Quantong [1 ,3 ]
Duan, Jizhou [1 ,3 ]
机构
[1] Key Laboratory of Marine Environment Corrosion and Bio-Fouling, Institute of Oceanology, Chinese Academy of Sciences, Qingdao,266071, China
[2] University of Chinese Academy of Sciences, Beijing,100049, China
[3] Open Studio for Marine Corrosion and Protection, Pilot National Laboratory for Marine Science and Technology (Qingdao), Qingdao,266237, China
[4] Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Shenyang,110819, China
关键词
Carbon - Chemical detection - Copper - Cyclic voltammetry - Electrochemical electrodes - Fourier transform infrared spectroscopy - Ionic liquids - Metal ions - Molar ratio;
D O I
10.13595/j.cnki.issn1000-0720.2022.070402
中图分类号
学科分类号
摘要
The covalent organic framework material TpBD-COF was synthesized by solvothermal reaction, and characterized using scanning electron microscopy and Fourier transform infrared spectroscopy. Then, COF-2-BPPF6-CPE was prepared by mixing TpBD-COF,carbon paste and ionic liquid [BPPF6] in a certain proportion, and the electrochemical performance of the working electrode was evaluated by cyclic voltammetry (CV) and differential pulse voltammetry (DPV). Copper ions can be sensitively responded on the modified electrode in a buffer solution of potassium hydrogen phthalate at pH 3.50. The results showed that the COF modified carbon paste electrode had higher peak current for copper ion, and the peak current was linearly related to the molar concentration of copper ion in the range of 1 to 200 μmol/L,with a linear correlation coefficient(R2) of 0.9997. The detection limit was 0.13 μmol/L. The modified electrode showed excellent selectivity, stability and reproducibility. The standard addition method was used for the determination of copper ions in water samples with recoveries in the range of 100.6%-101.2%. These results suggested that COF modified carbon paste electrodes can be applied to detect copper ions in water samples. © 2023 the authors.
引用
收藏
页码:1199 / 1204
相关论文
共 50 条
  • [1] Electrochemical detection of hydroquinone and catechol with covalent organic framework modified carbon paste electrode
    Xin, Yu
    Wang, Ning
    Wang, Chunli
    Gao, Wei
    Chen, Mingli
    Liu, Nazhen
    Duan, Jizhou
    Hou, Baorong
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2020, 877
  • [2] Electrochemical determination of copper ions in spirit drinks using carbon paste electrode modified with biochar
    Oliveira, Paulo Roberto
    Lamy-Mendes, Alyne C.
    Pissinati Rezende, Edivaltrys Inayve
    Mangrich, Antonio Salvio
    Marcolino Junior, Luiz Humberto
    Bergamini, Marcio F.
    [J]. FOOD CHEMISTRY, 2015, 171 : 426 - 431
  • [3] Electrochemical detection of bisphenol A in presence of catechol and hydroquinone at copper oxide modified carbon paste electrode
    Shruthi Vishwanath, M.
    Kumara Swamy, B. E.
    Vishnumurthy, K. A.
    [J]. MATERIALS CHEMISTRY AND PHYSICS, 2022, 289
  • [4] Silica gel modified carbon paste electrode for electrochemical detection of insulin
    Jaafariasl, Mehdi
    Shams, Esmaeil
    Amini, Mohammad Kazem
    [J]. ELECTROCHIMICA ACTA, 2011, 56 (11) : 4390 - 4395
  • [5] Electrochemical analysis of catecholamines at a carbon paste electrode modified with copper(II) phthalocyanine
    Laber, Charles H.
    Garrison, Kenneth E.
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2013, 245
  • [6] Chemically modified carbon paste electrode for the detection of lead, cadmium and zinc ions
    Koirala, Kisan
    Santos, Jose H.
    Tan, Ai Ling
    Ali, Mohammad A.
    Mirza, Aminul H.
    [J]. SENSOR REVIEW, 2016, 36 (04) : 339 - 346
  • [7] Electrochemical detection of phenolic estrogenic compounds at clay modified carbon paste electrode
    Belkamssa, N.
    Ouattara, L.
    Kawachi, A.
    Tsujimura, M.
    Isoda, H.
    Chtaini, A.
    Ksibi, M.
    [J]. TUNISIA-JAPAN SYMPOSIUM: R&D OF ENERGY AND MATERIAL SCIENCES FOR SUSTAINABLE SOCIETY, 2015, 596
  • [8] Carbon Paste Electrode Modified with PMBP: A Sensitive Sensor for Electrochemical Detection of Acetaminophen
    Mahbob, Emi Norzehan Mohamad
    Ahmad, Mohamad Syahrizal
    Isa, Illyas Md
    Hashim, Norhayati
    Ul-Hamid, Anwar
    Saidin, Mohamad Idris
    Si, Suyanta M.
    [J]. JOURNAL OF THE CHEMICAL SOCIETY OF PAKISTAN, 2024, 46 (02): : 130 - 145
  • [9] Enhanced electrochemical detection of DNA hybridization with carbon nanotube modified paste electrode
    Nie, Libo
    Guo, Huishi
    He, Quanguo
    Chen, Jianrong
    Miao, Yuqing
    [J]. JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2007, 7 (02) : 560 - 564
  • [10] Environmental analysis of copper ions with a carbon paste electrode modified with alfalfa biomass.
    Tiemann, K
    Gamez, G
    Parsons, J
    Bess-Oberto, L
    Armindariz, V
    Mahmoud, J
    Gardea-Torresdey, J
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2001, 221 : U479 - U479