DC component suppression of PV grid-connected inverter with improved PCI controller

被引:0
|
作者
Gan T. [1 ]
Liang L. [1 ]
Chen Y. [2 ]
Ding X. [1 ,3 ]
Chen Y. [2 ]
机构
[1] School of Electrical Engineering, Guangxi University, Nanning
[2] Shenzhen Yadiwei Technology Co., Ltd., Shenzhen
[3] Guangxi Vocational College of Water Resources and Electric Power, Nanning
来源
关键词
Disturbance rejection; Inverters; Observers; Phase compensation; Proportional complex integral(PCI)controller; PV;
D O I
10.19912/j.0254-0096.tynxb.2020-1223
中图分类号
学科分类号
摘要
The DC component injection issues exist in the non-isolated PV grid-connected inverter application. In this paper, an novel DC component suppression strategy was proposed based on an improved PCI controller. Firstly, considering the DC component as system disturbance, a disturbance observer(DOB) was designed to observe the system's DC component in real- time, then a compensation method was designed for suppressing DC component based on the observed value of DC component. Secondly, a resonance complex coefficient PCI controller was substitute for the traditional PCI controller to obtain more phase margin. Finally, the feasibility and validity of the proposed strategy were verified by the simulation and experimental results. © 2022, Solar Energy Periodical Office Co., Ltd. All right reserved.
引用
收藏
页码:93 / 100
页数:7
相关论文
共 22 条
  • [21] CHOI Y, YANG K, CHUNG W K, Et al., On the robustness and performance of disturbance observers for second-order systems, IEEE transactions on automatic control, 48, 2, pp. 315-320, (2003)
  • [22] IEEE Std 929-2000, IEEE recommended practice for utility interface of photovoltaic(PV)systems