Research on Optimal Fault-Tolerant Technique for Three-Level Active-Neutral-Point-Clamped Inverter Based on Switching Modulation Wave

被引:0
|
作者
Wei W. [1 ,2 ]
Gao Z. [1 ,2 ]
Zhao M. [1 ,2 ]
Zhao L. [1 ]
Li Y. [1 ,2 ]
Ge Q. [1 ]
机构
[1] Key Laboratory of Power Electronics and Electric Drive, Institute of Electrical Engineering, Chinese Academy of Sciences, Beijing
[2] University of Chinese Academy of Sciences, Beijing
来源
Diangong Jishu Xuebao/Transactions of China Electrotechnical Society | 2022年 / 37卷 / 15期
关键词
fault-tolerant; neutral-point voltage balance; open-switch fault; switching modulation wave; Three-level active-neutral-point-clamped inverter;
D O I
10.19595/j.cnki.1000-6753.tces.210758
中图分类号
学科分类号
摘要
The traditional fault-tolerant technique based on space vector PWM can realize the fault-tolerant operation of three-level active-neutral-point-clamped (ANPC) inverter without adding hardware equipment, but it has the defects of two-level jump, unbalanced neutral-point voltage, and output current distortion. To solve the above problems, this paper first analyzes the effective switching state of three-level ANPC inverter in the case of open-switch fault, and then deduces the modulation wave that can control three-phase only output negative, zero levels and positive, zero levels. On this basis, the modulation wave is selected according to the direction of the fault phase current, and the effective switching state is used to output the three-phase level, thus the optimal fault-tolerant technique based on switching modulation wave (OFTBSM) and its neutral-point voltage balance control strategy are proposed. Finally, the fault-tolerant performance, neutral-point voltage fluctuation, and harmonic performance of OFTBSM are analyzed. Simulation and experimental results prove that OFTBSM can make the ANPC inverter operate smoothly when the single-phase up to four switching devices have open-switch fault at the same time, and can prevent two-level jump, reduce current harmonics, and control the neutral-point voltage balance. In addition, OFTBSM also has the advantages of strong robustness, simple calculation, and convenient implementation. © 2022 Chinese Machine Press. All rights reserved.
引用
收藏
页码:3818 / 3833
页数:15
相关论文
共 23 条
  • [11] Zhu Qinyue, Xu Jingran, Tan Xitang, Et al., Fault-tolerant control of device sharing three-level inverter, Electric Machines and Control, 25, 7, pp. 107-119, (2021)
  • [12] Matos D B, Estima J O, Marques Cardoso A J., Performance of a synchronous reluctance motor drive with a fault-tolerant three-level neutral point clamped inverter, 2016 XXII International Conference on Electrical Machines (ICEM), pp. 1152-1159, (2016)
  • [13] (2020)
  • [14] Zhang Ming, Guo Yuanbo, Li Ze, Et al., Suppression algorithm for output voltage unbalance of three-level inverters under fault tolerant operation, Transactions of China Electrotechnical Society, 33, 22, pp. 5300-5310, (2018)
  • [15] Fu Wenxuan, Zhang Peng, Wang Yu, Et al., Research on fault tolerant control of three-level ANPC converter under open-circuit fault, Power Electronics, 51, 3, pp. 4-8, (2017)
  • [16] Yang Dong, Wei Rong, Sun Pengkun, Et al., Analysis and design of fault-tolerant control of ANPC inverter for traction system, 2019 22nd International Conference on Electrical Machines and Systems (ICEMS), pp. 1-4, (2019)
  • [17] Azer P, Ouni S, Narimani M., A novel fault-tolerant technique for active-neutral-point-clamped inverter using carrier-based PWM, IEEE Transactions on Industrial Electronics, 67, 3, pp. 1792-1803, (2020)
  • [18] Xu Shuai, Sun Zhenyao, Yao Chunxing, Et al., Open-switch fault-tolerant control strategy for three-level ANPC inverter based on hybrid carrier modulation, Proceedings of the CSEE, 41, 15, pp. 5329-5339, (2021)
  • [19] Li J, Xu Jing, Qi Lisa, Et al., Fault tolerant operation of 5L-ANPC converter, IECON 2014 - 40th Annual Conference of the IEEE Industrial Electronics Society, pp. 4464-4470, (2014)
  • [20] (2021)