Ferromagnetic microwires with low curie temperature for sensor applications

被引:0
|
作者
National Institute for R&D in Electrical Engineering ICPE-CA, Bucharest, Romania [1 ]
机构
来源
UPB Sci Bull Ser B | 2019年 / 3卷 / 179-186期
关键词
Glass;
D O I
暂无
中图分类号
学科分类号
摘要
Glass-coated ferromagnetic microwires, with low Curie temperature, used for temperature sensor were designed and complex characterized. Two alloys with low Curie temperature consisting of Fe-Ni-Cr-B-Si and Fe-Ni-Cr-Co-B-Si were developed. The microwires are covered by a thin layer of glass, thus increasing their corrosive protection, making the temperature sensors suited to work in corrosive environments. The active elements have a temperature range between 20°C and 200°C, with a sensitivity that depend on the number of microwires used in the design of the temperature sensor. © 2019, Politechnica University of Bucharest. All rights reserved.
引用
收藏
相关论文
共 50 条
  • [21] Curie temperature of a ferromagnetic polymer chain model
    Huang, Jian-Hua
    Luo, Meng-Bo
    Qian, Chang-Ji
    Journal of Applied Polymer Science, 1600, 99 (03): : 969 - 973
  • [22] CURIE-TEMPERATURE OF A DOPED FERROMAGNETIC SEMICONDUCTOR
    MATLAK, M
    SKROBIS, K
    PHYSICA STATUS SOLIDI B-BASIC RESEARCH, 1986, 135 (01): : 155 - 161
  • [23] CURIE-TEMPERATURE OF DEGENERATE FERROMAGNETIC SEMICONDUCTORS
    NAGAEV, EL
    SOKOLOVA, EB
    FIZIKA TVERDOGO TELA, 1977, 19 (02): : 533 - 538
  • [24] The pressure coefficient of the Curie temperature of ferromagnetic superconductors
    Konno, R.
    Hatayama, N.
    26TH INTERNATIONAL CONFERENCE ON LOW TEMPERATURE PHYSICS (LT26), PTS 1-5, 2012, 400
  • [25] PRESSURE DEPENDENCE OF CURIE TEMPERATURE OF FERROMAGNETIC METALS
    LIU, SH
    PHYSICAL REVIEW, 1962, 127 (06): : 1889 - +
  • [26] Biomimic Hairy Skin Tactile Sensor Based on Ferromagnetic Microwires
    Zhang, Jian
    Hao, Lifeng
    Yang, Fan
    Jiao, Weicheng
    Liu, Wenbo
    Li, Yibin
    Wang, Rongguo
    He, Xiaodong
    ACS APPLIED MATERIALS & INTERFACES, 2016, 8 (49) : 33848 - 33855
  • [27] Accuracy Improvement of Low-Invasive Temperature Measurement for Hyperthermia Treatment Using a Ferromagnetic Implant with Low Curie Temperature
    Miyamoto, Ryuhei
    Saito, Hajime
    Suzuki, Masafumi
    Yoshimura, Noboru
    Mitobe, Kazutaka
    ELECTRONICS AND COMMUNICATIONS IN JAPAN, 2016, 99 (03) : 55 - 62
  • [28] Accuracy improvement of low-invasive temperature measurement for hyperthermia treatment using a ferromagnetic implant with low curie temperature
    Miyamoto, Ryuhei
    Saito, Hajime
    Suzuki, Masafumi
    Yoshimura, Noboru
    Mitobe, Kazutaka
    Miyamoto, R. (mitobe@gipc.akita-u.ac.jp), 1600, Institute of Electrical Engineers of Japan (134): : 436 - 441
  • [29] Controlling the Curie temperature in amorphous glass coated microwires by heat treatment
    Dzhumazoda, A.
    Panina, L., V
    Nematov, M. G.
    Tabarov, F. S.
    Morchenko, A. T.
    Bazlov, A., I
    Ukhasov, A.
    Yudanov, N. A.
    Podgornaya, S., V
    JOURNAL OF ALLOYS AND COMPOUNDS, 2019, 802 : 36 - 40
  • [30] Preparation of ferromagnetic (In,Mn)As with relatively low hole concentration and Curie temperature 50 K
    Slupinski, T
    Oiwa, A
    Yanagi, S
    Munekata, H
    JOURNAL OF CRYSTAL GROWTH, 2002, 237 : 1326 - 1330