FLUID FLOW AND HEAT TRANSFER CHARACTERISTICS OF A CENTERED-WICK HEAT PIPE WITH ADDITIONAL WORKING FLUID: EXPERIMENTAL STUDY WITH VISUALIZATION

被引:0
|
作者
Koito Y. [1 ]
Chen C. [2 ]
Kakizoe R. [2 ]
Fukushima A. [2 ]
机构
[1] Division of Industrial Fundamentals, Faculty of Advanced Science and Technology, Kumamoto University, 2-39-1 Kurokami, Chuo-ku, Kumamoto
[2] Department of Mechanical and Mathematical Engineering, Graduate School of Science and Technology, Kumamoto University, 2-39-1 Kurokami, Chuo-ku, Kumamoto
关键词
condensation; electronics cooling; evaporation; heat transfer device; liquid slug; two-phase flow;
D O I
10.1615/MultScienTechn.v35.i2.30
中图分类号
学科分类号
摘要
This article describes the experimental study of the centered-wick heat pipe with additional working fluid. A semi-transparent heat pipe is employed, and the heat transfer experiments are conducted in three orientation modes: horizontal, vertical, and sideways. The wick structure is a sintered copper powder, and the working fluid is water. The heat pipe has a small gap between the wick structure and the container wall. In each orientation mode, a condenser section of the heat pipe is water-cooled with a cooling jacket, and an evaporator section is heated with a heater. Fluid-flow and phase-change phenomena in the heat pipe are captured by using a video camera, and the temporal changes in the temperatures of the heat pipe are obtained by using thermocouples. Due to the additional working fluid, liquid slugs are found in vapor flow channels. The liquid slugs can be categorized into two types: a dynamic liquid slug and a static liquid slug. The experimental results demonstrate that the dynamic and static liquid slugs are distributed more effectively in the horizontal orientation mode. Thus, the thermal resistance of the heat pipe tends to be smaller and the maximum heat input to the heat pipe is larger in the horizontal orientation mode than in the other two orientation modes. The experimental results also confirm that the small gap is effective in the horizontal orientation mode. The additional working fluid is stored in the gap, which increases the thermal performance of the heat pipe. © 2023 by Begell House, Inc.
引用
收藏
页码:43 / 55
页数:12
相关论文
共 50 条
  • [31] Experimental study of fluid flow and heat transfer characteristics in the square channel with a perforation baffle
    Huang, K. David
    Tzeng, Sheng-Chung
    Jeng, Tzer-Ming
    Wang, Jee-Ray
    Cheng, Sen-Yao
    Tseng, Kuo-Tung
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2008, 35 (09) : 1106 - 1112
  • [32] Fluid flow and heat transfer in flat-plate oscillating heat pipe
    Liu, Xiangdong
    Chen, Yongping
    ENERGY AND BUILDINGS, 2014, 75 : 29 - 42
  • [33] Experimental Study on Heat Transfer Characteristics of Thermosyphon with Methanol-Based Binary Working Fluid
    Lu, Jinli
    Huang, Ru
    Han, Yafang
    Sun, Yanhong
    Yue, Shengnan
    Wang, Changlong
    Wang, Qiwei
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY-TRANSACTIONS OF MECHANICAL ENGINEERING, 2024, 48 (04) : 1825 - 1837
  • [34] Working Fluid Inventory Effect on Heat Transfer Performance of a Grooved Micro Heat Pipe
    Li, Xibing
    Ma, Yunshi
    Wang, Xun
    Li, Ming
    ADVANCES IN MACHINING AND MANUFACTURING TECHNOLOGY XII, 2014, 589-590 : 559 - 564
  • [35] Modeling for Fluid Flow and Heat Transfer in Closed Loop Pulsating Heat Pipe
    Sarangi, R. K.
    Kar, S. P.
    Rane, M., V
    Swain, A.
    Pothal, L. K.
    JOURNAL OF THERMAL SCIENCE AND ENGINEERING APPLICATIONS, 2021, 13 (04)
  • [36] Fluid flow and heat transfer in a dual-wet micro heat pipe
    Zhang, Jin
    Watson, Stephen J.
    Wong, Harris
    JOURNAL OF FLUID MECHANICS, 2007, 589 (1-31) : 1 - 31
  • [37] Heat transfer characteristic of oscillating flow heat pipe with nano-fluid
    Yamaguchi, Kentaro
    Yamada, Noboru
    Nihon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 2013, 79 (801): : 819 - 821
  • [38] Heat transfer increase for a laminar pipe flow of a magnetic fluid subjected to constant heat flux: Improvements and additional discussions
    Gontijo, R. G.
    MECHANICS RESEARCH COMMUNICATIONS, 2018, 94 : 64 - 69
  • [39] An experimental study and CFD analysis towards heat transfer and fluid flow characteristics of decaying swirl pipe flow generated by axial vanes
    Ahmadvand, M.
    Najafi, A. F.
    Shahidinejad, S.
    MECCANICA, 2010, 45 (01) : 111 - 129
  • [40] An experimental study and CFD analysis towards heat transfer and fluid flow characteristics of decaying swirl pipe flow generated by axial vanes
    M. Ahmadvand
    A. F. Najafi
    S. Shahidinejad
    Meccanica, 2010, 45 : 111 - 129