Sensitive and simultaneous quantification of 16 neurotransmitters and metabolites in murine microdialysate by fast liquid chromatography-tandem mass spectrometry

被引:10
|
作者
Becker S. [1 ]
Schulz A. [2 ]
Kreyer S. [2 ]
Dreßler J. [1 ]
Richter A. [2 ]
Helmschrodt C. [2 ]
机构
[1] Institut of Legal Medicine, Department of Forensic Toxicology, University Leipzig
[2] Institute of Pharmacology, Pharmacy and Toxicology, Faculty of Veterinary Medicine, University of Leipzig, Leipzig
关键词
Basal values; Deoxy carnitine; LC-MS/MS; Murine microdialysis; Neurochemistry; Neurotransmitter;
D O I
10.1016/j.talanta.2022.123965
中图分类号
学科分类号
摘要
The sensitive and simultaneous measurement of multiple neurotransmitters in microdialysate (MD) of freely moving mice is a prerequisite to study neurochemical imbalances in specific brain regions. The quantitative analysis of 16 neurotransmitters and metabolites, including serotonin (5-HT), 5-hydroxyindoleacetic acid (5-HIAA), melatonin (ME), dopamine (DA), levodopa (L-DOPA), 3-methoxytyramine (3-MT), norepinephrine (NE), epinephrine (EP), homovanillinic acid (HVA), acetylcholine (ACh), deoxy carnitine (iso-ACh), choline (Ch), and ɣ-aminobutyric acid (GABA), adenosine (ADE), glutamine (Gln), and glutamic acid (Glu) was achieved within a chromatographic separation time of 6.5 min by the application of a biphenyl column coupled to an API-QTrap 5500 (AB SCIEX) mass spectrometer. Optimized chromatographic separation as well as high sensitivity allow the simultaneous analysis and precise quantification of 16 neurotransmitters and metabolites in artificial cerebrospinal fluid (CSF). Sample preparation procedure consisted of simply adding isotopically labeled internal standard solution to the microdialysis sample. The limits of detection in aCSF ranged from 0.025 pg (Ch) to 9.75 pg (Gln) and 85.5 pg (HVA) on column. Recoveries were between 83 and 111% for neurotransmitter concentrations from 0.6 to 45 ng/ml or 200 ng/ml with a mean intra-day and inter-day coefficient of variation of 7.6% and 11.2%, respectively. Basal extracellular concentrations of the following analytes: 5-HT, 5-HIAA, ME, DA, 3-MT, HVA, ACh, iso-ACh, Ch, GABA, ADE, Gln, and Glu were determined in the striatum of mice with a MD flow rate of 0.5 μl/min. This LC-MS/MS method leads to an accurate quantification of ACh and its isobaric structure iso-ACh, which were detected in the MD samples at ratios of 1:8.6. The main advantage of the high sensitivity is the miniaturization of the MD protocol with short sample collection times and volumes down to 5 μl, which makes this method suitable for pharmacological intervention and optogenetic studies to detect neurochemical changes in vivo. © 2022 The Authors
引用
收藏
相关论文
共 50 条
  • [21] Quantification of methylone and metabolites in rat and human plasma by liquid chromatography-tandem mass spectrometry
    Kayla N. Ellefsen
    Marta Concheiro
    Masaki Suzuki
    Kenner C. Rice
    Joshua S. Elmore
    Michael H. Baumann
    Marilyn A. Huestis
    Forensic Toxicology, 2015, 33 : 202 - 212
  • [22] Identification and quantification of tamoxifen and four metabolites in serum by liquid chromatography-tandem mass spectrometry
    Gjerde, J
    Kisanga, ER
    Hauglid, M
    Holm, PI
    Mellgren, G
    Lien, EA
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1082 (01) : 6 - 14
  • [23] Method for quantification of opioids and their metabolites in autopsy blood by liquid chromatography-tandem mass spectrometry
    Al-Asmari, Ahmed I.
    Anderson, Robert A.
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2007, 31 (07) : 394 - 408
  • [24] Quantification of methylone and metabolites in rat and human plasma by liquid chromatography-tandem mass spectrometry
    Ellefsen, Kayla N.
    Concheiro, Marta
    Suzuki, Masaki
    Rice, Kenner C.
    Elmore, Joshua S.
    Baumann, Michael H.
    Huestis, Marilyn A.
    FORENSIC TOXICOLOGY, 2015, 33 (02) : 202 - 212
  • [25] Quantification of six cannabinoids and metabolites in oral fluid by liquid chromatography-tandem mass spectrometry
    Desrosiers, Nathalie A.
    Scheidweiler, Karl B.
    Huestis, Marilyn A.
    DRUG TESTING AND ANALYSIS, 2015, 7 (08) : 684 - 694
  • [26] Multiplexed quantification of venlafaxine and metabolites in human plasma by liquid chromatography-tandem mass spectrometry
    Pandey, Aashish
    Price, Amelia
    Ayala-Lopez, Nadia
    Garza, Kyana Y.
    Marzinke, Mark A.
    Knezevic, Claire E.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2024, 243
  • [27] Simultaneous Determination of Flonicamid and its Metabolites in Tea by Liquid Chromatography-Tandem Mass Spectrometry
    Zhang, Qingtao
    Yang, Ya
    Liu, Xiangwu
    Chen, Ya
    Hu, Deyu
    Lu, Ping
    ANALYTICAL LETTERS, 2019, 52 (06) : 948 - 961
  • [28] Rapid quantification of murine bile acids using liquid chromatography-tandem mass spectrometry
    Hermeling, Sven
    Plagge, Johannes
    Krautbauer, Sabrina
    Ecker, Josef
    Burkhardt, Ralph
    Liebisch, Gerhard
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2025, 417 (04) : 687 - 696
  • [29] Simultaneous quantification of tiloronoxim and tilorone in human urine by liquid chromatography-tandem mass spectrometry
    Zhang, Xianhua
    Yang, Li
    Zhai, Suodi
    Duan, Jingli
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 875 (02): : 349 - 357
  • [30] Simultaneous Phenotyping and Quantification of α-1-Antitrypsin by Liquid Chromatography-Tandem Mass Spectrometry
    Chen, Yuhong
    Snyder, Melissa R.
    Zhu, Yi
    Tostrud, Linda J.
    Benson, Linda M.
    Katzmann, Jerry A.
    Bergen, H. Robert, III
    CLINICAL CHEMISTRY, 2011, 57 (08) : 1161 - 1168