Sensitive and simultaneous quantification of 16 neurotransmitters and metabolites in murine microdialysate by fast liquid chromatography-tandem mass spectrometry

被引:10
|
作者
Becker S. [1 ]
Schulz A. [2 ]
Kreyer S. [2 ]
Dreßler J. [1 ]
Richter A. [2 ]
Helmschrodt C. [2 ]
机构
[1] Institut of Legal Medicine, Department of Forensic Toxicology, University Leipzig
[2] Institute of Pharmacology, Pharmacy and Toxicology, Faculty of Veterinary Medicine, University of Leipzig, Leipzig
关键词
Basal values; Deoxy carnitine; LC-MS/MS; Murine microdialysis; Neurochemistry; Neurotransmitter;
D O I
10.1016/j.talanta.2022.123965
中图分类号
学科分类号
摘要
The sensitive and simultaneous measurement of multiple neurotransmitters in microdialysate (MD) of freely moving mice is a prerequisite to study neurochemical imbalances in specific brain regions. The quantitative analysis of 16 neurotransmitters and metabolites, including serotonin (5-HT), 5-hydroxyindoleacetic acid (5-HIAA), melatonin (ME), dopamine (DA), levodopa (L-DOPA), 3-methoxytyramine (3-MT), norepinephrine (NE), epinephrine (EP), homovanillinic acid (HVA), acetylcholine (ACh), deoxy carnitine (iso-ACh), choline (Ch), and ɣ-aminobutyric acid (GABA), adenosine (ADE), glutamine (Gln), and glutamic acid (Glu) was achieved within a chromatographic separation time of 6.5 min by the application of a biphenyl column coupled to an API-QTrap 5500 (AB SCIEX) mass spectrometer. Optimized chromatographic separation as well as high sensitivity allow the simultaneous analysis and precise quantification of 16 neurotransmitters and metabolites in artificial cerebrospinal fluid (CSF). Sample preparation procedure consisted of simply adding isotopically labeled internal standard solution to the microdialysis sample. The limits of detection in aCSF ranged from 0.025 pg (Ch) to 9.75 pg (Gln) and 85.5 pg (HVA) on column. Recoveries were between 83 and 111% for neurotransmitter concentrations from 0.6 to 45 ng/ml or 200 ng/ml with a mean intra-day and inter-day coefficient of variation of 7.6% and 11.2%, respectively. Basal extracellular concentrations of the following analytes: 5-HT, 5-HIAA, ME, DA, 3-MT, HVA, ACh, iso-ACh, Ch, GABA, ADE, Gln, and Glu were determined in the striatum of mice with a MD flow rate of 0.5 μl/min. This LC-MS/MS method leads to an accurate quantification of ACh and its isobaric structure iso-ACh, which were detected in the MD samples at ratios of 1:8.6. The main advantage of the high sensitivity is the miniaturization of the MD protocol with short sample collection times and volumes down to 5 μl, which makes this method suitable for pharmacological intervention and optogenetic studies to detect neurochemical changes in vivo. © 2022 The Authors
引用
收藏
相关论文
共 50 条
  • [1] Development of a fast liquid chromatography-tandem mass spectrometry method for simultaneous quantification of neurotransmitters in murine microdialysate
    Christin Helmschrodt
    Susen Becker
    Stefanie Perl
    Anja Schulz
    Angelika Richter
    Analytical and Bioanalytical Chemistry, 2020, 412 : 7777 - 7787
  • [2] Development of a fast liquid chromatography-tandem mass spectrometry method for simultaneous quantification of neurotransmitters in murine microdialysate
    Helmschrodt, Christin
    Becker, Susen
    Perl, Stefanie
    Schulz, Anja
    Richter, Angelika
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2020, 412 (28) : 7777 - 7787
  • [3] A simple and sensitive liquid chromatography-tandem mass spectrometry assay for the quantification of ertapenem in microdialysate
    Lefeuvre, Sandrine
    Venisse, Nicolas
    Marchand, Sandrine
    Bachelet, Mickael
    Couet, William
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 862 (1-2): : 242 - 245
  • [4] Simultaneous quantification of nicotine and metabolites in rat brain by liquid chromatography-tandem mass spectrometry
    Vieira-Brock, Paula L.
    Miller, Eleanor I.
    Nielsen, Shannon M.
    Fleckenstein, Annette E.
    Wilkins, Diana G.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (30): : 3465 - 3474
  • [5] A Reliable Method Based on Liquid Chromatography-Tandem Mass Spectrometry for the Simultaneous Quantification of Neurotransmitters in Caenorhabditis elegans
    Weishaupt, Ann-Kathrin
    Kubens, Laura
    Ruecker, Lysann
    Schwerdtle, Tanja
    Aschner, Michael
    Bornhorst, Julia
    MOLECULES, 2023, 28 (14):
  • [6] Simultaneous Quantification of Triazolam and its Metabolites in Human Urine by Liquid Chromatography-Tandem Mass Spectrometry
    Pan, Ryh-Nan
    Hsiong, Cheng-Huei
    Huang, Pei-Wei
    Tsai, Wei-Shiuan
    Li, Wen-Yi
    Pao, Li-Heng
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2011, 35 (03) : 170 - 175
  • [7] Validation of a simple, fast liquid chromatography-tandem mass spectrometry method for the simultaneous quantification of 40 antidepressant drugs or their metabolites in plasma
    Degreef, Maarten
    van Nuijs, Alexander L. N.
    Maudens, Kristof E.
    CLINICA CHIMICA ACTA, 2018, 485 : 243 - 257
  • [8] Simultaneous quantification of 37 synthetic cannabinoid metabolites in human urine by liquid chromatography-tandem mass spectrometry
    Jang, Moonhee
    Shin, Ilchung
    Kim, Jihyun
    Yang, Wonkyung
    FORENSIC TOXICOLOGY, 2015, 33 (02) : 221 - 234
  • [9] Simultaneous Quantification of Diazepam, Flunitrazepam and Metabolites in Reinforced Clostridial Medium by Liquid Chromatography-Tandem Mass Spectrometry
    Martindale, Stephanie M.
    Powers, Robert H.
    Bell, Suzanne C.
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2015, 39 (01) : 29 - 34
  • [10] Simultaneous quantification of 37 synthetic cannabinoid metabolites in human urine by liquid chromatography-tandem mass spectrometry
    Moonhee Jang
    Ilchung Shin
    Jihyun Kim
    Wonkyung Yang
    Forensic Toxicology, 2015, 33 : 221 - 234