Fixed Low-Order Wide-Area Damping Controller Considering Time Delays and Power System Operation Uncertainties

被引:0
|
作者
Bento, Murilo E. C. [1 ]
机构
[1] University of Sao Paulo, São Carlos SP,13566-590, Brazil
来源
IEEE Transactions on Power Systems | 2020年 / 35卷 / 05期
关键词
Electric power system control - Cybersecurity - Outages - Damping - Riccati equations - Time delay - Modal analysis - Controllers - Network security - Phasor measurement units;
D O I
暂无
中图分类号
学科分类号
摘要
This paper presents a procedure for the design of a Wide-Area Damping Controller (WADC) towards improving the low-frequency oscillation modes of the power system considering uncertainties in both nominal power system operation condition and time delay on the WADC communication channels. A set of possible operating conditions is linearized around their equilibrium points and used for the construction of the uncertainty model of the system. The lower and upper limits of the time delay are also included in the set. The WADC operation requires remote signals provided by Phasor Measurement Units and highly susceptible to failures or cyber-attacks that may compromise the controller performance. The proposed procedure evaluates in each stage if the resulting controller presents robustness to communication channel permanent failure. Modal analysis and time-domain nonlinear simulations were conducted in the IEEE 68-bus power system. © 1969-2012 IEEE.
引用
收藏
页码:3918 / 3926
相关论文
共 50 条
  • [21] Wide-Area Power Oscillation Damping With a Fuzzy Controller Compensating the Continuous Communication Delays
    Mokhtari, Maghsoud
    Aminifar, Farrokh
    Nazarpour, Daryoosh
    Golshannavaz, Sajjad
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2013, 28 (02) : 1997 - 2005
  • [22] An Adaptive Wide-Area Damping Control Scheme Considering Networked Induced Time Delays
    Yalcin, Samil Baycan
    Basel, Mahir Bulent
    Mete, Ahmet Naci
    2018 6TH INTERNATIONAL CONFERENCE ON CONTROL ENGINEERING & INFORMATION TECHNOLOGY (CEIT), 2018,
  • [23] A design method of the wide-area damping controller of the power system considering the communication time-delay based on an iterative identification
    Yu, Miao
    Shang, Weipeng
    Lu, Haoyang
    INTERNATIONAL JOURNAL OF ELECTRONICS, 2018, 105 (09) : 1551 - 1567
  • [24] Robust Centralized Fixed Order Wide Area Damping Controller for wind integrated power system
    Maherani, Mahshid
    Erlich, Istvan
    Krost, Gerhard
    IFAC PAPERSONLINE, 2019, 52 (04): : 170 - 175
  • [25] Design of a wide-area damping controller to tolerate permanent communication failure and time delay uncertainties
    Bento, Murilo E. C.
    ENERGY SYSTEMS-OPTIMIZATION MODELING SIMULATION AND ECONOMIC ASPECTS, 2022, 13 (01): : 235 - 264
  • [26] Design of a wide-area damping controller to tolerate permanent communication failure and time delay uncertainties
    Murilo E. C. Bento
    Energy Systems, 2022, 13 : 235 - 264
  • [27] Direct Intelligent Wide-Area Damping Controller for Wind Integrated Power System
    Yousefian, Reza
    Bhattarai, Rojan
    Kamalasadan, S.
    2016 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING (PESGM), 2016,
  • [28] Impact of Time Delays on the Performance of a Wide-Area Damping Controller Under Reduced Inertia Scenarios
    Kellermueller, Sandro
    Ramirez-Gonzalez, Miguel
    Obushevs, Artjoms
    Korba, Petr
    2023 IEEE BELGRADE POWERTECH, 2023,
  • [29] Nonlinear hierarchical global controller considering wide-area information delays
    School of Electrical Engineering, Xi'an Jiaotong University, Xi'an 710049, China
    不详
    Hsi An Chiao Tung Ta Hsueh, 2007, 12 (1460-1464):
  • [30] A synchrophasor measurement based wide-area power system stabilizer design for inter-area oscillation damping considering variable time-delays
    Prakash, Tapan
    Singh, Vinay Pratap
    Mohanty, Soumya R.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2019, 105 : 131 - 141