PCE10 Significantly Improves Red and Near-infrared Light Detection Capabilities of Ternary Photomultiplication-type Organic Photodetectors

被引:0
|
作者
Wang J. [1 ]
Tang X. [2 ]
Zhou B. [1 ]
Zeng X. [1 ]
Li J. [1 ]
Zhou Y. [1 ]
机构
[1] College of Physics & Electronics Information Engineering, Minjiang University, Fuzhou
[2] College of Optoelectronic Engineering, Chongqing University of Posts and Telecommunications, Chongqing
来源
关键词
blood oxygen saturation; bulk-heterojunction; heart rate; near-infrared; photomultiplication-type organic photodetector; ternary;
D O I
10.37188/CJL.20230257
中图分类号
学科分类号
摘要
Photodetectors with strong near-infrared response are more conducive to detecting human heart rate. Furthermore,broadband photodetectors with a response range covering both red and near-infrared region can be used to detect blood oxygen saturation. Therefore,improving the red and near-infrared response capabilities of broadband photodetectors is of great significance. However,classic binary bulk-heterojunction broadband photomultiplication-type organic photodetectors typically exhibit weak or even no response to red and near-infrared light due to significant ratio-difference between donor and acceptor in the active layer. This paper fabricates ternary bulk-heterojunction photomultiplication-type organic photodetectors with a structure of ITO/PEDOT∶PSS/P3HT∶PCE10∶IEICO-4F(90∶10∶ 1)/Al by using a small amount of donor material PCE10 to replace some of P3HT in the active layer of P3HT∶IEICO-4F(100∶1). Under -20 V bias,the ternary devices obtain a relatively even EQE spectrum from ultraviolet to near-infrared(330-810 nm),with the EQEs at 660 nm and 810 nm(134000% and 147000%)being 78 and 106 times as large as those of the binary devices under same conditions,and corresponding detectivity values(5. 4×1013 Jones and 7. 27×1013 Jones)being increased by 26 and 36 times,respectively. The red and near-infrared light detection capabilities of ternary devices have been significantly improved,providing a strategy for fabricating high-performance photodetectors to detect human heart rate and blood oxygen saturation. © 2023 Chines Academy of Sciences. All rights reserved.
引用
收藏
页码:2222 / 2230
页数:8
相关论文
共 38 条
  • [21] WANG W B, ZHANG F J, Et al., Improved performance of photomultiplication polymer photodetectors by adjustment of P3HT molecular arrangement[J], ACS Appl. Mater. Interfaces, 7, 40, pp. 22660-22668, (2015)
  • [22] BAI H T, WANG Y F,, CHENG P,, Et al., An electron acceptor based on indacenodithiophene and 1,1-dicyanomethylene-3-indanone for fullerene-free organic solar cells[J], J. Mater. Chem. A, 3, 5, pp. 1910-1914, (2015)
  • [23] BAI H T, WANG Z Y,, Et al., A planar electron acceptor for efficient polymer solar cells[J], Energy Environ. Sci, 8, 11, pp. 3215-3221, (2015)
  • [24] LIN Y Z, WANG J Y,, ZHANG Z G,, Et al., An electron acceptor challenging fullerenes for efficient polymer solar cells [J], Adv. Mater, 27, 7, pp. 1170-1174, (2015)
  • [25] ASHRAF R S, Et al., High-efficiency and air-stable P3HT-based polymer solar cells with a new non-fullerene acceptor[J], Nat. Commun, 7, 1, (2016)
  • [26] YU R N,, Et al., Design,synthesis,and photovoltaic characterization of a small molecular acceptor with an ultra-narrow band gap[J], Angew. Chem. Int. Ed, 56, 11, pp. 3045-3049, (2017)
  • [27] WANG W B, ZHANG F J, BAI H T,, Et al., Photomultiplication photodetectors with P3HT:fullerene-free material as the active layers exhibiting a broad response[J], Nanoscale, 8, 10, pp. 5578-5586, (2016)
  • [28] ZHANG Y J, Et al., Synergistic effect of polymer and small molecules for high-performance ternary organic solar cells[J], Adv. Mater, 27, 6, pp. 1071-1076, (2015)
  • [29] ZHENG L Y,, XIAO Z,, Et al., Functionality of non-fullerene electron acceptors in ternary organic solar cells[J], Sol. RRL, 3, 12, (2019)
  • [30] ZHANG F J, Et al., Improved efficiency of bulk heterojunction polymer solar cells by doping low-bandgap small molecules[J], ACS Appl. Mater. Interfaces, 6, 9, pp. 6537-6544, (2014)