A novel conductive membrane sensor protection technique to mitigate redox-active interferences

被引:0
|
作者
DeBrosse M.C. [1 ,2 ]
Suresh S. [1 ]
Karajic A. [1 ]
Kim S. [2 ]
Hussain S. [2 ]
Heikenfeld J. [1 ]
机构
[1] Novel Device Lab, University of Cincinnati, Cincinnati, 45221, OH
[2] 711th Human Performance Wing, Air Force Research Laboratory, Wright-Patterson AFB, 45433, OH
来源
Biosensors and Bioelectronics: X | 2023年 / 14卷
基金
美国国家科学基金会;
关键词
Biosensors; Conductive; Electrochemical glucose biosensors; Membranes; Redox-active interferents;
D O I
10.1016/j.biosx.2023.100366
中图分类号
学科分类号
摘要
Due to their high specificity and selectivity, receptor-based biosensors play an important role in real-time health monitoring. However, maintaining an ideal homeostatic sensor environment while correcting for the physiological variability of biofluids is imperative. Biological media contain an abundance of interfering species which if not addressed, can render the biosensor inoperable. Enzyme-based electrochemical sensors are particularly susceptible to redox-active interferences as these increase analyte detection limits, making physiological measurements a challenge. For this reason, extensive research has been applied to develop various strategies to mitigate such interferences. Here we present a novel conductive membrane encapsulation strategy designed to mitigate redox-active interferences while allowing redox-inactive target analyte to pass through unaltered to the sensor surface. This redox-active mitigation strategy is highly generalizable as the potential across the conductive membrane can be easily modified. Using a first-generation glucose oxidase sensor as a model interferent-sensitive system, we have shown a 72 percent reduction in redox-active interference and an 8-fold decrease in detection limit upon implementation of our conductive membrane strategy. © 2023
引用
收藏
相关论文
共 50 条
  • [21] A planar amperometric creatinine biosensor employing an insoluble oxidizing agent for removing redox-active interferences
    Shin, JH
    Choi, YS
    Lee, HJ
    Choi, SH
    Ha, J
    Yoon, IJ
    Nam, H
    Cha, GS
    ANALYTICAL CHEMISTRY, 2001, 73 (24) : 5965 - 5971
  • [22] Voltammetric DNA Sensor Based on Redox-Active Dyes for Determining Doxorubicin
    D. Kappo
    Yu. I. Kuzin
    D. N. Shurpik
    I. I. Stoikov
    G. A. Evtyugin
    Journal of Analytical Chemistry, 2022, 77 : 94 - 100
  • [23] Solution conformations of novel redox-active cyclophane based on biindolizinequinoxaline
    Balandina, Alsu
    Mamedov, Vakhid
    Latypov, Shamil
    JOURNAL OF MOLECULAR STRUCTURE, 2008, 889 (1-3) : 89 - 97
  • [24] Voltammetric DNA Sensor Based on Redox-Active Dyes for Determining Doxorubicin
    Kappo, D.
    Kuzin, Yu, I
    Shurpik, D. N.
    Stoikov, I. I.
    Evtyugin, G. A.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2022, 77 (01) : 94 - 100
  • [25] Cupricyclins, Novel Redox-Active Metallopeptides Based on Conotoxins Scaffold
    Barba, Marco
    Sobolev, Anatoli P.
    Zobnina, Veranika
    di Patti, Maria Carmela Bonaccorsi
    Cervoni, Laura
    Spiezia, Maria Carolina
    Schinina, M. Eugenia
    Pietraforte, Donatella
    Mannina, Luisa
    Musci, Giovanni
    Polticelli, Fabio
    PLOS ONE, 2012, 7 (02):
  • [26] SYNTHESIS AND STUDY OF A NOVEL REDOX-ACTIVE METALLOPEPTIDE STRUCTURAL DOMAIN
    EASON, PD
    SHULLENBERGER, DF
    LONG, EC
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1994, 208 : 73 - BIOL
  • [27] Novel redox-active macrocycles containing the ferrocene unit.
    Wagner, M
    Ding, L
    Ma, KB
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2001, 221 : U687 - U688
  • [28] Plasmoredoxin, a novel redox-active protein unique for malarial parasites
    Becker, K
    Kanzok, SM
    Iozef, R
    Fischer, M
    Schirmer, RH
    Rahlfs, S
    EUROPEAN JOURNAL OF BIOCHEMISTRY, 2003, 270 (06): : 1057 - 1064
  • [29] Electrically Redox-Active Membrane with Switchable Selectivity to Contaminants for Water Purification
    Liu, Lie
    Lan, Huachun
    Cui, Yuqi
    An, Xiaoqiang
    Sun, Meng
    Liu, Huijuan
    Qu, Jiuhui
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2023, 57 (45) : 17640 - 17648
  • [30] Erratum to: Voltammetric DNA Sensor Based on Redox-Active Dyes for Determining Doxorubicin
    D. Kappo
    Yu. I. Kuzin
    D. N. Shurpik
    I. I. Stoikov
    G. A. Evtyugin
    Journal of Analytical Chemistry, 2022, 77 : 388 - 388