Conducted electromagnetic emissions of compact fluorescent lamps and electronic ballast modeling

被引:0
|
作者
Yeshalem M.T. [1 ]
Khan B. [1 ]
Mahela O.P. [2 ]
机构
[1] Department of Electrical and Computer Engineering, Hawassa University, Hawassa
[2] Power System Planning Division, Rajasthan Rajya Vidyut Prasaran Nigam Ltd., Jaipur
来源
关键词
conducted EM emissions; power quality; resonant inverters; self-oscillating ballasts; supraharmonics frequency;
D O I
10.3934/ELECTRENG.2022011
中图分类号
学科分类号
摘要
The higher frequency electromagnetic (EM) emission in low voltage power systems is rising continuously due to the increasing use of modern electronic devices. The electronic ballast of a compact fluorescent lamp (CFL) is one of the sources of conducted EM emission in the power system. Conducted EM emission measurements are performed on compact fluorescent lamps (CFL) in the range of 2–150 kHz and compared with simulation results. The LTSpice simulation of typical 11W compact fluorescent lamps is used to analyze the measured values. Comparisons are made in both the time and frequency domains. The EMI filter in the ballast circuit can reduce the level of high-frequency EM emission. However, in order to get a more accurate result, it is necessary to find out the main cause of conducted EM emission in the ballast circuit, as the HF distortion spreads through the LV network in current signal between electronic devices. © 2022 the Author(s), licensee AIMS Press.
引用
收藏
页码:178 / 187
页数:9
相关论文
共 50 条
  • [31] Microcontrolled electronic gear for hid lamps -: Comparisons with electromagnetic ballast
    Có, MA
    Rezende, CZ
    Simonetti, DSL
    Vieira, JLF
    IECON-2002: PROCEEDINGS OF THE 2002 28TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-4, 2002, : 468 - 472
  • [32] Modeling of fluorescent lamp for electronic ballast
    Yi, CW
    Kim, YJ
    IPEMC 2000: THIRD INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-3, PROCEEDINGS, 2000, : 1451 - 1455
  • [33] Optical radiation emissions from compact fluorescent lamps
    Khazova, M.
    O'Hagan, J. B.
    RADIATION PROTECTION DOSIMETRY, 2008, 131 (04) : 521 - 525
  • [34] A Boost-Type High Power Factor Single Switch Electronic Ballast for Compact Fluorescent Lamps (Energy-Saving Lamps)
    Lam, John
    Jain, Praveen K.
    IECON 2011: 37TH ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2011,
  • [35] A simple method to design resonant circuits of electronic ballast for fluorescent lamps
    Li, Z
    Mok, PKT
    Ki, WH
    Sin, JKO
    ISCAS '97 - PROCEEDINGS OF 1997 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS, VOLS I - IV: CIRCUITS AND SYSTEMS IN THE INFORMATION AGE, 1997, : 1744 - 1747
  • [36] The Influence of Fluorescent Lamps with Electronic Ballast on the Low Voltage PLC Network
    Emleh, A.
    de Beer, A. S.
    Ferreira, H. C.
    Vinck, A. J. Han
    2014 IEEE 8TH INTERNATIONAL POWER ENGINEERING AND OPTIMIZATION CONFERENCE (PEOCO), 2014, : 276 - 280
  • [37] Electronic ballast for fluorescent lamps with the PFC stage integrated with the resonant inverter
    Pereira, EI
    Nascimento, CB
    Perin, AJ
    PESC 04: 2004 IEEE 35TH ANNUAL POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-6, CONFERENCE PROCEEDINGS, 2004, : 4050 - 4056
  • [38] Design and implementation of electronic ballast for fluorescent lamps with low lighting flicker
    Lin, Yang-Sheng
    Cheng, Chun-An
    Chen, Jiann-Fuh
    Liang, Tsorng-Juu
    Liu, Wei-Shih
    IPEMC 2006: CES/IEEE 5TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE, VOLS 1-3, CONFERENCE PROCEEDINGS, 2006, : 1178 - +
  • [39] Battery-Operated Electronic Ballast of Fluorescent Lamps for Photovoltaic Applications
    Chuang, Ying-Chun
    Ke, Yu-Lung
    Chuang, Hung-Shiang
    CONFERENCE RECORD OF THE 2007 IEEE INDUSTRY APPLICATIONS CONFERENCE FORTY-SECOND IAS ANNUAL MEETING, VOLS. 1-5, 2007, : 1442 - +
  • [40] Electronic ballast for operating fluorescent lamps over wide temperature range
    Moo, CS
    Lin, TF
    Chuang, YC
    IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2003, 150 (02): : 153 - 157