Effect of tilt angle on the performance and electrical parameters of a PV module: Comparative indoor and outdoor experimental investigation

被引:0
|
作者
Mamun M.A.A. [1 ]
Islam M.M. [1 ]
Hasanuzzaman M. [1 ]
Selvaraj J. [1 ]
机构
[1] Higher Institution Centre of Excellence (HICoE), UM Power Energy Dedicated Advanced Centre (UMPEDAC), Level 4, Wisma R&D, University of Malaya, Jalan Pantai Baharu, Kuala Lumpur
来源
Energy and Built Environment | 2022年 / 3卷 / 03期
关键词
Irradiation intensity; Module electrical parameters; Photovoltaic; PV performance; Tilt angle;
D O I
10.1016/j.enbenv.2021.02.001
中图分类号
学科分类号
摘要
Photovoltaic (PV) system's performance is significantly affected by its orientation and tilt angle. Experimental investigation (indoor and outdoor) has been carried out to trace the variation in PV performance and electrical parameters at varying tilt angles in Malaysian conditions. There were two experimental modus: 1) varying module tilt under constant irradiation level, 2) varying irradiation intensity at the optimum tilt set up. For the former scheme, the irradiation level was maintained at 750 W/m2, and for the later arrangement, the module tilt angle was varied from 0o to 80o by means of a single-axis tracker. Results show that under constant irradiation of 750 W/m2, every 5o increase in tilt angle causes a power drop of 2.09 W at indoor and 3.45 W at outdoor. In contrast, for the same condition, efficiency decreases by 0.54% for indoor case and by 0.76% at outdoor. On the other hand, for every 100 W/m2 increase in irradiation, solar cell temperature rises by 7.52°C at indoor and by 5.67°C at outdoor. As of module electrical parameters, open-circuit voltage, short-circuit current, maximum power point voltage and maximum power point current drops substantially with increasing tilt angle, whereas fill factor drops rather gradually. Outdoor experimental investigation confirms that the optimum tilt angle at Malaysian conditions is 15o and orienting a PV module this angle will maximize the sun's energy captured and thereby enhance its performance. © 2021 Elsevier Ltd
引用
收藏
页码:278 / 290
页数:12
相关论文
共 50 条
  • [31] Experimental investigation on effect of stator vane angle adjustment on compressor performance
    Zhang, Jian
    Ren, Minglin
    Hangkong Dongli Xuebao/Journal of Aerospace Power, 2000, 15 (01): : 27 - 30
  • [32] Real time Data Acquisition system for Performance Analysis of modified PV module and derivation of cooling coefficients of Electrical parameters
    Sharma, Madhu
    Bansal, Kamal
    Buddhi, Dharam
    INTERNATIONAL CONFERENCE ON COMPUTER, COMMUNICATION AND CONVERGENCE (ICCC 2015), 2015, 48 : 582 - 588
  • [33] Experimental Investigation of Heat Pipe Inclination Angle Effect on Temperature Nonuniformity in Electrical Machines
    Zhang, Xiaochen
    Zhao, Han
    Li, Jing
    Zhang, Fengyu
    Zhang, Yue
    Yan, Hongyu
    Niu, Zhihao
    Gerada, David
    Zhang, He
    ENERGIES, 2023, 16 (01)
  • [34] Effect of various parameters on the performance of solar PV power plant: a review and the experimental study
    Shaik, Feroz
    Lingala, Syam Sundar
    Veeraboina, Punnaiah
    Sustainable Energy Research, 2023, 10 (01)
  • [35] Effect of the overhead height and tilt angle on comprehensive performance of photovoltaic roof based on simulation and experimental methods
    Zheng, Wenheng
    He, Huihui
    Qin, Fuyu
    Lan, Yuncheng
    Yin, Yingde
    RESULTS IN ENGINEERING, 2025, 25
  • [36] Experimental Investigation of the Effect of a Combination of Active and Passive Cooling Mechanism on the Thermal Characteristics and Efficiency of Solar PV Module
    Agyekum, Ephraim Bonah
    PraveenKumar, Seepana
    Alwan, Naseer T.
    Velkin, Vladimir Ivanovich
    Shcheklein, Sergey E.
    Yaqoob, Salam J.
    INVENTIONS, 2021, 6 (04)
  • [37] Experimental investigation on the impact of thermal energy storage on the solar still performance coupled with PV module via new integration
    Abd Elbar, Ayman Refat
    Hassan, Hamdy
    SOLAR ENERGY, 2019, 184 : 584 - 593
  • [38] Electrical Performance and Degradation Analysis of Field-Aged PV Modules in Tropical Climates: A Comparative Experimental Study
    Islam, Md. Imamul
    Bin Jadin, Mohd Shawal
    Al Mansur, Ahmed
    Alharbi, Talal
    ENERGY CONVERSION AND MANAGEMENT-X, 2024, 24
  • [39] Experimental and numerical investigation of the thermal performance of phase-change module using built-in electrical heating
    Niu, Dongyin
    Zhang, Tiantian
    Zhang, Xuedan
    Tan, Yufei
    Zhang, Wensheng
    ENERGY AND BUILDINGS, 2023, 299
  • [40] Experimental investigation of the effects of the coolant on the performance parameters of electrical discharge drilling of some aerospace materials
    Gov, Kursad
    JOURNAL OF THE FACULTY OF ENGINEERING AND ARCHITECTURE OF GAZI UNIVERSITY, 2017, 32 (01): : 293 - 301