A Dosimetric Comparison of Volumetric-Modulated Arc Therapy to Intensity-Modulated Radiation Therapy in the Treatment of Locally Advanced Rectal Carcinoma

被引:0
|
作者
Eldebawy E. [1 ,2 ]
Rashed Y.A. [2 ,3 ,4 ]
AlKhaldi M. [2 ,5 ]
Day E. [2 ,6 ]
机构
[1] Consultant of Radiation Oncology, National Cancer Institute, Cairo University
[2] King Fahad Specialist Hospital, Dammam
[3] Medical Physics Dept., Faculty of Medicine, Menofiya University
[4] Consultant of Radiation Oncology Physics, King Fahad Specialist Hospital, Dammam
[5] Medical Physicist (Radiation Oncology Physics), Radiation Oncology Department, Medical Physics Unit, King Fahad Specialist Hospital, Dammam
[6] Radiation Therapist, King Fahad Specialist Hospital, Dammam
关键词
Rectal Cancer VMAT Intensity Modulated Dosimetry Comparison;
D O I
10.22038/ijmp.2019.42941.1652
中图分类号
学科分类号
摘要
Introduction: The study was conducted to compare volumetric-modulated arc therapy (VMAT) with intensity-modulated radiation therapy (IMRT) in patients with locally advanced rectal cancer (LARC). Material and Methods: Ten computed tomography (CT) scans were selected and for each CT scan, two plans were created (IMRT and VMAT). The average cumulative dose-volume histograms (DVH) of VMAT plans for the planning target volumes (PTVs), organs at risk (OARs), and normal tissues were calculated and compared with those reported for the corresponding IMRT technique. Results: Target coverage was equivalent for both techniques. For primary PTV, the average homogeneity index (HI) of IMRT was significantly lower than the VMAT plans (0.10±0.04 vs. 0.11±0.03; P<0.0001). The average conformity index (CI) values for IMRT and VMAT were 1.21 and 1.12, respectively, with a nonsignificant trend for better results with VMAT (P=0.1). For the PTV boost, there was a nonsignificant trend for better results with VMAT in average HI and CI. The VMAT was superior to IMRT in OAR sparing. For monitor units (MUs), VMAT plans required 70% less MUs than IMRT. Conclusion: For LARC patients, VMAT was able to deliver treatment plans dosimetrically equivalent to IMRT in terms of PTV coverage. The VMAT provided better OAR sparing and significant reduction of MUs in comparison to IMRT. © 2020. All Rights Reserved.
引用
收藏
页码:374 / 379
页数:5
相关论文
共 50 条
  • [31] Dosimetric comparison of intensity-modulated radiation therapy and volumetric-modulated arc therapy plans for the treatment of glioma using flattening filter-free and flattening filter modes
    Xu, Dandan
    Jia, Fei
    Li, Guowen
    Li, Hongfei
    ONCOLOGY LETTERS, 2017, 13 (05) : 3451 - 3456
  • [32] Plan comparison of volumetric-modulated arc therapy (RapidArc) and conventional intensity-modulated radiation therapy (IMRT) in anal canal cancer
    Vieillot, Sabine
    Azria, David
    Lemanski, Claire
    Moscardo, Carmen Llacer
    Gourgou, Sophie
    Dubois, Jean-Bernard
    Ailleres, Norbert
    Fenoglietto, Pascal
    RADIATION ONCOLOGY, 2010, 5
  • [33] Dosimetric Comparison of Helical Tomotherapy, Volume-Modulated Arc Therapy, and Fixed-Field Intensity-Modulated Radiation Therapy in Locally Advanced Nasopharyngeal Carcinoma
    Lu, Shan
    Fan, Huiqi
    Hu, Xueyuan
    Li, Xin
    Kuang, Yingying
    Yu, Deyang
    Yang, Shanshan
    FRONTIERS IN ONCOLOGY, 2021, 11
  • [34] Plan comparison of volumetric-modulated arc therapy (RapidArc) and conventional intensity-modulated radiation therapy (IMRT) in anal canal cancer
    Sabine Vieillot
    David Azria
    Claire Lemanski
    Carmen Llacer Moscardo
    Sophie Gourgou
    Jean-Bernard Dubois
    Norbert Aillères
    Pascal Fenoglietto
    Radiation Oncology, 5
  • [35] Intensity-modulated radiotherapy, volume-modulated arc therapy and helical tomotherapy for locally advanced nasopharyngeal carcinoma: a dosimetric comparison
    Chen, Wen
    Yang, Xiaoyu
    Jiang, Nian
    Zhang, Zijian
    Hong, Jidong
    He, Yuxiang
    Luo, Junli
    Liang, Ying
    Wei, Rui
    TRANSLATIONAL CANCER RESEARCH, 2017, 6 (05) : 929 - 939
  • [36] Dosimetric Comparison of Hypofractionated Regimen in Breast Cancer Using Two Different Techniques: Intensity-Modulated Radiation Therapy (IMRT) and Volumetric-Modulated Arc Therapy (VMAT)
    Prasun, Pallav
    Kharade, Vipin
    Pal, Vikas
    Gupta, Manish
    Das, Saikat
    Pasricha, Rajesh
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (04)
  • [37] Dosimetric comparison between step-shoot intensity-modulated radiotherapy and volumetric-modulated arc therapy for upper thoracic and cervical esophageal carcinoma
    Gao, Min
    Li, Qilin
    Ning, Zhonghua
    Gu, Wendong
    Huang, Jin
    Mu, Jinming
    Pei, Honglei
    MEDICAL DOSIMETRY, 2016, 41 (02) : 131 - 135
  • [38] Analytical dosimetric study of intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) for prostate cancer
    Samir, Fady
    Meaz, Talaat M.
    Hussiny, Fathi AEl
    Ahmed, Ahmed A.
    Mahmoud, Amr A.
    Refaat, Tamer
    Gawish, Ahmed
    Abouegylah, Mohamed
    JOURNAL OF CANCER RESEARCH AND CLINICAL ONCOLOGY, 2023, 149 (09) : 6239 - 6246
  • [39] A dosimetric comparative study: Volumetric modulated arc therapy vs intensity-modulated radiation therapy in the treatment of nasal cavity carcinomas
    Kham Nguyen
    Cummings, David
    Lanza, Vincent C.
    Morris, Kathleen
    Wang, Congjun
    Sutton, Jordan
    Garcia, John
    MEDICAL DOSIMETRY, 2013, 38 (03) : 225 - 232
  • [40] Analytical dosimetric study of intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) for prostate cancer
    Fady Samir
    Talaat M. Meaz
    Fathi AEl Hussiny
    Ahmed A. Ahmed
    Amr A. Mahmoud
    Tamer Refaat
    Ahmed Gawish
    Mohamed Abouegylah
    Journal of Cancer Research and Clinical Oncology, 2023, 149 : 6239 - 6246