Influence of salt concentration on the performance characteristics of passive solar still

被引:22
|
作者
Dumka P. [1 ]
Mishra D.R. [1 ]
机构
[1] Department of Mechanical Engineering, Jaypee University of Engineering and Technology, Guna, Madhya Pradesh
关键词
Desalination; passive solar still; salt concentration;
D O I
10.1080/01430750.2019.1611638
中图分类号
学科分类号
摘要
In this paper, an attempt has been made to investigate the impact of salt concentration on the internal heat transfer coefficients of a geographically south facing conventional solar still. The experiments were conducted on seven different days for seven different salt concentrations (i.e. 0%, 0.5%, 1%, 1.5%, 2%, 2.5% and 3%). The evaporative heat transfer coefficient at 1% of salt concentration is higher by 461.70%, 82.63%, 144.95%, 71.54%, 146.91% and 156.12% as compared with the 0%, 0.5%, 1.5%, 2%, 2.5% and 3% of salt concentrations, respectively. An average value of overall heat transfer coefficient at 1% of salt concentration has maintained its lead throughout the experimentation as compared to other salt concentrations. On the basis of results obtained through the experimental and theoretical evaluation, it has been observed that at 1% of salt concentration the distiller unit will give better performance. © 2019 Informa UK Limited, trading as Taylor & Francis Group.
引用
收藏
页码:1463 / 1473
页数:10
相关论文
共 50 条
  • [21] Influence of Carrier Concentration on the Performance of CIAS Solar Cell
    Patel, Kinjal
    Ray, Jaymin
    INTERNATIONAL CONFERENCE ON NANOMATERIALS FOR ENERGY CONVERSION AND STORAGE APPLICATIONS (NECSA 2018), 2018, 1961
  • [22] Developments and modifications in passive solar still: a review
    Panchal, Hitesh
    Sadashivuni, Kishor
    Sathyamurthy, Ravishankar
    Mevada, Dinesh
    DESALINATION AND WATER TREATMENT, 2019, 143 : 158 - 164
  • [23] Influence of the salt concentration on the electrochemical performance of electrodes for polymeric batteries
    Gerlach, P.
    Burges, R.
    Lex-Balducci, A.
    Schubert, U. S.
    Balducci, A.
    ELECTROCHIMICA ACTA, 2019, 306 : 610 - 616
  • [24] Thermal modeling and performance of a single slope passive solar still with phase change material
    Nithyanandam, C.
    Baskar, G.
    Umamaheswari, R.
    DESALINATION AND WATER TREATMENT, 2018, 103 : 1 - 10
  • [25] Study the effect of CuO nanoparticles on the performance of passive solar still in winter and summer season
    Thakur, Vikas Kumar
    Gaur, Manoj Kumar
    MATERIALS TODAY-PROCEEDINGS, 2022, 57 : 2009 - 2017
  • [26] THERMAL-CHARACTERISTICS AND PERFORMANCE OF SALT GRADIENT SOLAR PONDS
    BENIWAL, RS
    SINGH, R
    BAKORE, PV
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 1987, 11 (03) : 343 - 357
  • [27] Effect of solar area concentration ratio on performance of a conventional solar still with air humidification-dehumidification
    Al-Otoom, A. Y.
    Tamimi, A. I.
    Abandeh, S. Z.
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2015, 7 (05)
  • [28] Analyzing the influence of water depth on active conical solar still performance
    Nandan Kumar
    Abhishek Saxena
    Desh Bandhu Singh
    Sumit Tiwari
    Shiv Lal
    undefined Harender
    Journal of Mechanical Science and Technology, 2025, 39 (4) : 1681 - 1688
  • [29] SOLAR-STILL PERFORMANCE
    MAALEJ, AY
    DESALINATION, 1991, 82 (1-3) : 207 - 219
  • [30] Experimental studies on passive inclined solar panel absorber solar still
    C. Sasikumar
    A. Muthu Manokar
    M. Vimala
    D. Prince Winston
    A. E. Kabeel
    Ravishankar Sathyamurthy
    Ali J. Chamkha
    Journal of Thermal Analysis and Calorimetry, 2020, 139 : 3649 - 3660