Influence of Diameter of FGM Implant on Stress Distribution

被引:0
|
作者
Elleuch, Sameh [1 ]
Jrad, Hanen [1 ,3 ]
Wali, Mondher [1 ,2 ]
Dammak, Fakhreddine [1 ]
机构
[1] Laboratory of Electromechanical Systems (LASEM), National Engineering School of Sfax, University of Sfax, Route de Soukra km 4, Sfax,3038, Tunisia
[2] Department of Mechanical Engineering, College of Engineering, King Khalid University, Abha, Saudi Arabia
[3] École supérieure des sciences et de la technologie de Hammam Sousse, University of Sousse, Rue Lamine Abassi, Hammam Sousse,4011, Tunisia
关键词
Compilation and indexing terms; Copyright 2024 Elsevier Inc;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:49 / 55
相关论文
共 50 条
  • [31] Finite Element Analysis of the Influence of Implant Inclination on Stress Distribution in Mandibular Overdentures
    Ebadian, Behnaz
    Mosharraf, Ramin
    Khodaeian, Niloufar
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (03) : 252 - 257
  • [32] Influence of bone elastic properties on the predicted stress distribution in the dental implant vicinity
    Nutu, Emil
    Ahmad, Saad
    Pastrama, Stefan
    MATERIALS TODAY-PROCEEDINGS, 2017, 4 (05) : 5904 - 5908
  • [33] The influence of the connection, length and diameter of an implant on bone biomechanics
    Borie, Eduardo
    Orsi, Iara Augusta
    de Araujo, Carlos P. R.
    ACTA ODONTOLOGICA SCANDINAVICA, 2015, 73 (05) : 321 - 329
  • [34] Influence of cortical bone quality on stress distribution in bone around dental implant
    Kitagawa, T
    Tanimoto, Y
    Nemoto, K
    Aida, M
    DENTAL MATERIALS JOURNAL, 2005, 24 (02) : 219 - 224
  • [35] Effect of Implant Diameter and Ridge Dimension on Stress Distribution in Mandibular First Molar Sites-A Photoelastic Study
    Termeie, Deborah
    Klokkevold, Perry R.
    Caputo, Angelo A.
    JOURNAL OF ORAL IMPLANTOLOGY, 2015, 41 (05) : E165 - E173
  • [36] Effects of dental implant diameter and tapered body design on stress distribution in rigid polyurethane foam during insertion
    Yang, Baixuan
    Landa, Ainara Irastorza
    Heuberger, Peter
    Ploeg, Heidi -Lynn
    MEDICAL ENGINEERING & PHYSICS, 2024, 129
  • [37] Stress distribution in dental implant with elastomeric stress barrier
    Achour, T.
    Merdji, A.
    Bouiadjra, B. Bachir
    Serier, B.
    Djebbar, N.
    MATERIALS & DESIGN, 2011, 32 (01) : 282 - 290
  • [38] Influence of maxillary cortical bone thickness, implant design and implant diameter on stress around implants: A three-dimensional finite element analysis
    Okumura, Nobuaki
    Stegaroiu, Roxana
    Kitamura, Eriko
    Kurokawa, Kouichi
    Nomura, Shuichi
    JOURNAL OF PROSTHODONTIC RESEARCH, 2010, 54 (03) : 133 - 142
  • [39] DESIGN AND FABRICATION OF A NEW FGM IMPLANT
    Yazdi, H. asadolahi
    Kumar, Abhinav
    Abullais, Shahabe saquib
    Alghazali, Tawfeeq
    Yeslam, Hanin e.
    SURFACE REVIEW AND LETTERS, 2025,
  • [40] Influence of Bone and Dental Implant Parameters on Stress Distribution in the Mandible: A Finite Element Study
    Guan, Hong
    van Staden, Rudi
    Loo, Yew-Chaye
    Johnson, Newell
    Ivanovski, Saso
    Meredith, Neil
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2009, 24 (05) : 866 - 876