Analysis and fitting of a thorax path loss based on implantable galvanic coupling intra-body communication

被引:0
|
作者
Zhang S. [1 ,2 ,3 ,4 ]
Li Y. [1 ]
Yu Y. [1 ,4 ]
Kuang J.-M. [1 ,4 ]
Yang J. [1 ,4 ]
Wang J. [1 ,4 ]
Liu Y. [1 ,4 ]
机构
[1] Data Recovery Key Laboratory of Sichuan Province, College of Computer Science & AI, Neijiang Normal University, Neijiang, Sichuan
[2] School of Life Science and Technology, University of Electronic Science and Technology of China, Chengdu, Sichuan
[3] High Field Magnetic Resonance Brain Imaging Laboratory of Sichuan, Neijiang Normal University, Chengdu, Sichuan
[4] BeiDou & Wisdom Medical Doctor Workstation, Neijiang Normal University, Neijiang, Sichuan
关键词
Body-Area Network (BAN); Implantable communication; Intra-body communication; Path loss; Thorax;
D O I
10.2174/2666255813999200831110505
中图分类号
R4 [临床医学]; R318 [生物医学工程]; Q81 [生物工程学(生物技术)];
学科分类号
0831 ; 0836 ; 090102 ; 1002 ; 100602 ;
摘要
Objective: The aim of this research was to study the channel transmission characteristics of living and dead animal bodies and signal path loss characteristics of implantable communication in the axial direction. Methods: By injecting fentanyl citrate injection solution, we kept the research object (a piglet) in a comatose state and then a death state, so as to analyze the channel characteristics in each state. To analyze channel gain when using an implantable device with a fixed implantation depth and varying the axial distance, we proposed an implantable two-way communication path loss model. Results: Comparing the living-body and dead-body results showed that the channel gain difference was approximately 10dB for the same position and distance, heartbeat, pulse and breathing of the living animal contributed approximately 1dB of noise. Analyzing the calculated and experimental results of the path loss model showed that the determination correlation coefficients of the model were 0.999 and 0.998, respectively. The model prediction result and the experimental verification result also agreed closely. Conclusion: The path loss model not only fits the experimental results but also has better predictabil-ity for those positions not measured. © 2021 Bentham Science Publishers.
引用
收藏
页码:969 / 974
页数:5
相关论文
共 50 条
  • [41] Investigation on Error Performance for Galvanic-type Intra-body Communication with Experiment
    Li, Jia Wen
    Chen, Xi Mei
    Mak, Peng Un
    Pun, Sio Hang
    Lam, Chan-Tong
    Gao, Yue Ming
    Vai, Mang I.
    Du, Min
    2014 7TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON), 2014,
  • [42] The Theoretical Analysis and FE Simulation of Electrostatic Coupling Intra-Body Communication Based on Upper Arm Model
    Song, Yong
    Zhang, Kai
    Kang, Bangzhi
    Shang, Fuzhou
    Yang, Guang
    Hao, Qun
    INFORMATION AND BUSINESS INTELLIGENCE, PT II, 2012, 268 : 77 - 83
  • [43] Noise analysis for intra-body communication based on parasitic capacitance measurement
    Shinagawa, Mitsuru
    Katsuyama, Jun
    Matsumoto, Kazuki
    Hasegawa, Shinya
    Sugiyama, Ryo
    Kado, Yuichi
    MEASUREMENT, 2014, 51 : 206 - 213
  • [45] The Simulation of Electrostatic Coupling Intra-body Communication based on Finite-element Models
    Song Yong
    Yang Guang
    Hao Qun
    Wang Ming
    2008 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: ADVANCED SENSOR TECHNOLOGIES AND APPLICATIONS, 2009, 7157
  • [46] Effect of Human Movement on Galvanic Intra-Body Communication during Single Gait Cycle
    Ibrahim, I. W.
    Razak, A. H. A.
    Ahmad, A.
    Salleh, M. K. M.
    4TH INTERNATIONAL CONFERENCE ON ELECTRONIC DEVICES, SYSTEMS AND APPLICATIONS 2015 (ICEDSA), 2015, 99
  • [47] Analysis of Unintentional Signal Propagation in Intra-Body Communication
    Nezu, Kenta
    Sato, Yuki
    Shinagawa, Mitsuru
    Saito, Daisuke
    Seo, Ken
    Oohashi, Kyoji
    2018 IEEE 7TH GLOBAL CONFERENCE ON CONSUMER ELECTRONICS (GCCE 2018), 2018, : 101 - 104
  • [48] Development and performance analysis of an intra-body communication device
    Hachisuka, K
    Nakata, A
    Takeda, T
    Terauchi, Y
    Shiba, K
    Sasaki, K
    Hosaka, H
    Itao, K
    BOSTON TRANSDUCERS'03: DIGEST OF TECHNICAL PAPERS, VOLS 1 AND 2, 2003, : 1722 - 1725
  • [49] Health Monitoring System Based on Intra-Body Communication
    Razak, A. H. A.
    Ibrahim, I. W.
    Ayub, A. H.
    Amri, M. F.
    Hamzi, M. H.
    Halim, A. K.
    Ahmad, A.
    Al Junid, S. A. M.
    4TH INTERNATIONAL CONFERENCE ON ELECTRONIC DEVICES, SYSTEMS AND APPLICATIONS 2015 (ICEDSA), 2015, 99
  • [50] Radiated noise analysis via human body for intra-body communication
    Hayashida, Yuki
    Hasegawa, Mari
    Suzuki, Akito
    Shinagawa, Mitsuru
    Kado, Yuichi
    Haga, Nozomi
    MEASUREMENT, 2016, 89 : 159 - 165