Temperature dependence of the light yield of the LAB-based and mesitylene-based liquid scintillators

被引:0
|
作者
夏冬梅 [1 ,2 ]
俞伯祥 [1 ]
李小波 [1 ]
孙希磊 [1 ]
丁雅韵 [1 ]
周莉 [1 ]
曹俊 [1 ]
胡为 [1 ,2 ]
叶星辰 [3 ]
陈海涛 [4 ]
丁雪峰 [3 ]
杜冰 [1 ]
机构
[1] State Key Laboratory of Particle Detection and Electronics, Institute of High Energy Physics,Chinese Academy of Sciences
[2] University of Chinese Academy of Sciences
[3] School of Physics and Technology, and Key Laboratory of Artificial Micro- and Nano-structures of Ministry of Education, Wuhan University
[4] Nanjing University of Aeronautics and
关键词
D O I
暂无
中图分类号
O572.321 [];
学科分类号
摘要
We studied the temperature dependence of the light yield of linear alkyl benzene(LAB)-based and mesitylene-based liquid scintillators. The light yield increases by 23% for both liquid scintillators when the temperature is lowered from 26 to-40, correcting for the temperature response of the photomultiplier tube. The measurements help to understand the energy response of liquid scintillator detectors. Especially, the next generation reactor neutrino experiments for neutrino mass hierarchy, such as the Jiangmen Underground Neutrino Observatory(JUNO), require very high energy resolution. As no apparent degradation on the liquid scintillator transparency was observed, lowering the operation temperature of the detector to ~4 will increase the photoelectron yield of the detector by 13%, combining the light yield increase of the liquid scintillator and the quantum efficiency increase of the photomultiplier tubes.
引用
收藏
页码:31 / 35
页数:5
相关论文
共 50 条
  • [31] The Internet of Drinks Lab-Based Research for the Taste of It
    Lewandowski, Marco
    Schmidt, Kolja
    Kielhorn, Christoph
    Uckelmann, Dieter
    IMPACT OF VIRTUAL, REMOTE, AND REAL LOGISTICS LABS, 2012, 282 : 156 - +
  • [32] Lab-based researchers earn prize in economics
    Holden, C
    SCIENCE, 2002, 298 (5593) : 528 - 528
  • [33] A Study of the Literature on Lab-Based Instruction in Biology
    Puttick, Gillian
    Drayton, Brian
    Cohen, Eliza
    AMERICAN BIOLOGY TEACHER, 2015, 77 (01): : 12 - 18
  • [34] A Lab-based Test To Evaluate Pedometer Longevity
    McKenzie, James
    Manning, Tommy F.
    Juergens, Cheryl A.
    Heil, Daniel P.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2005, 37 : S117 - S117
  • [35] TCP/IP essentials: A lab-based approach
    Harle, Rob
    LEONARDO, 2006, 39 (05) : 484 - 485
  • [36] Lab-based Ultrafast Molecular Structure.
    Fullagar, Wilfred
    Uhlig, Jens
    Gador, Nildas
    Kinnuen, Kimmo
    Maasilta, Ilari
    Wahlstrom, Claes-Goran
    Sundstrom, Villy
    SRI 2009: THE 10TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION, 2010, 1234 : 919 - +
  • [37] In Situ Formation of Suspended Graphene Windows for Lab-Based XPS in Liquid and Gas Environments
    Jones, Elizabeth S.
    Drivas, Charalampos
    Gibson, Joshua S.
    Swallow, Jack E. N.
    Jones, Leanne A. H.
    Bricknell, Thomas D. J.
    van Spronsen, Matthijs A.
    Held, Georg
    Isaacs, Mark A.
    Parlett, Christopher M. A.
    Weatherup, Robert S.
    CHEMCATCHEM, 2024, 16 (16)
  • [38] TEMPERATURE DEPENDENCE OF ENERGY DEGRADATION IN ORGANIC LIQUID SCINTILLATORS
    LEVIN, EM
    FURST, M
    KALLMANN, H
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1968, NS15 (03) : 114 - &
  • [39] Temperature quenching in LAB based liquid scintillator
    A. Sörensen
    S. Hans
    A. R. Junghans
    B. v. Krosigk
    T. Kögler
    V. Lozza
    A. Wagner
    M. Yeh
    K. Zuber
    The European Physical Journal C, 2018, 78
  • [40] Temperature quenching in LAB based liquid scintillator
    Soerensen, A.
    Hans, S.
    Junghans, A. R.
    Krosigk, B. V.
    Koegler, T.
    Lozza, V.
    Wagner, A.
    Yeh, M.
    Zuber, K.
    EUROPEAN PHYSICAL JOURNAL C, 2018, 78 (01):