Disposable amperometric biosensors based on xanthine oxidase immobilized in the Prussian blue modified screen-printed three-electrode system

被引:0
|
作者
TENG YuanJieCHEN ChenZHOU ChangXiangZHAO HongLi LAN MinBo Shanghai key Laboratory of Functional Materials Chemistry
Research Center of Analysis TestEast China University of Science and TechnologyShanghai China [200237 ]
机构
关键词
D O I
暂无
中图分类号
学科分类号
摘要
The screen-printed three-electrode system was applied to fabricate a new type of disposable amperometric xanthine oxidase biosensor.Carbon-working,carbon-counter and Ag/AgCl reference electrodes were all manually printed on the polyethylene terephthalate substrate forming the screen-printed three-electrode system by the conventional screen-printing process.As a mediator,Prussian blue could not only catalyze the electrochemical reduction of hydrogen peroxide produced from the enzyme reaction,but also keep the favorable potential around 0 V.The optimum operational conditions,including pH,potential and temperature,were investigated.The sensitivities of xanthine and hypoxanthine detections were 13.83 mA/M and 25.56 mA/M,respectively.A linear relationship was obtained in the concentration range between 0.10μM and 4.98μM for xanthine and between 0.50μM and 3.98μM for hypoxanthine.The small Michaelis-menten constant value of the xanthine oxidase biosensor was calculated to be 3.90 μM.The results indicate that the fabricated xanthine oxidase biosensor is effective and sensitive for the detection of xanthine and hypoxanthine.
引用
收藏
页码:2581 / 2586
页数:6
相关论文
共 50 条
  • [41] Disposable Amperometric Sensor for Neurotransmitters Based on Screen-Printed Electrodes Modified with a Thin Iridium Oxide Film
    Abdollah Salimi
    Vali Alizadeh
    Richard G. Compton
    Analytical Sciences, 2005, 21 : 1275 - 1280
  • [42] Disposable amperometric sensor for neurotransmitters based on screen-printed electrodes modified with a thin iridium oxide film
    Salimi, A
    Alizadeh, V
    Compton, RG
    ANALYTICAL SCIENCES, 2005, 21 (11) : 1275 - 1280
  • [43] Amperometric glucose biosensors based on Prussian Blue- and polyaniline-glucose oxidase modified electrodes
    Garjonyte, R
    Malinauskas, A
    BIOSENSORS & BIOELECTRONICS, 2000, 15 (9-10): : 445 - 451
  • [44] Capabilities of amperometric monoamine oxidase biosensors based on screen-printed graphite electrodes modified with multiwall carbon nanotubes in the determination of some antidepressants
    Medyantseva, E. P.
    Brusnitsyn, D. V.
    Varlamova, R. M.
    Beshevets, M. A.
    Budnikov, H. C.
    Fattakhova, A. N.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 70 (05) : 535 - 539
  • [45] Screen-printed Paper-based Three-electrode System with Long-term Stable and Instantaneously Usable Reference Electrode
    Shitanda, Isao
    Komoda, Masato
    Hoshi, Yoshinao
    Itagaki, Masayuki
    CHEMISTRY LETTERS, 2018, 47 (12) : 1502 - 1504
  • [46] Capabilities of amperometric monoamine oxidase biosensors based on screen-printed graphite electrodes modified with multiwall carbon nanotubes in the determination of some antidepressants
    E. P. Medyantseva
    D. V. Brusnitsyn
    R. M. Varlamova
    M. A. Beshevets
    H. C. Budnikov
    A. N. Fattakhova
    Journal of Analytical Chemistry, 2015, 70 : 535 - 539
  • [47] A novel and Disposable Amperometric Hydrazine Sensor based on Polydimethyldiallylamine Stabilized Copper(II)hexacyanoferrate Nanocubes modified Screen-printed Carbon Electrode
    Ramaraj, Sukanya
    Sakthivel, Rajalakshmi
    Chen, Shen-Ming
    Palanisamy, Selvakumar
    Velusamy, Vijayalakshmi
    Chen, Tse-Wei
    Ramaraj, Sayee Kannan
    Pandian, Kannaiyan
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (06): : 5567 - 5580
  • [48] A new disposable amperometric NADH sensor based on screen-printed electrode modified with reduced graphene oxide/polyneutral red/gold nanoparticle
    Kamac, Melike Bilgi
    Onat, Eda Kiymaz
    Yilmaz, Merve
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2020, 100 (04) : 419 - 431
  • [49] Use of Screen-printed Electrodes Modified by Prussian Blue and Analogues in Sensing of Cysteine
    Bonacin, Juliano A.
    Dos Santos, Pamyla L.
    Katic, Vera
    Foster, Christopher W.
    Banks, Craig E.
    ELECTROANALYSIS, 2018, 30 (01) : 170 - 179
  • [50] Amperometric sensing of ascorbic acid using a disposable screen-printed electrode modified with electrografted o-aminophenol film
    Nassef, Hossam M.
    Civit, Laia
    Fragoso, Alex
    O'Sullivan, Ciara K.
    ANALYST, 2008, 133 (12) : 1736 - 1741