Assessment of accuracy of liver fluke diagnostic tests using the gold standard of total worm counts

被引:0
|
作者
Dowling, A. [1 ]
Lawrence, K. E. [2 ]
Howe, L. [2 ]
Scott, I. [2 ]
Pomroy, W. E. [2 ]
机构
[1] PGG Wrightson Ltd, 1 Robin Mann Pl, Christchurch, New Zealand
[2] Massey Univ, Palmerston North, New Zealand
关键词
Fasciola hepatica; cattle; New Zealand; Gold standard test; FASCIOLA-HEPATICA INFECTION; IGG ANTIBODIES; DAIRY-COWS; CATTLE; ELISA; EFFICACY; SHEEP; MILK; TRICLABENDAZOLE; RESISTANCE;
D O I
10.1016/j.vprsr.2024.101102
中图分类号
R38 [医学寄生虫学]; Q [生物科学];
学科分类号
07 ; 0710 ; 09 ; 100103 ;
摘要
In many regions of New Zealand liver fluke is endemic, infecting most grazing ruminants, including cattle, sheep, and deer. Restricting the economic losses and welfare costs associated with liver fluke relies on accurately identifying those animals with a production limiting infection. This has proven a difficult goal and although several antemortem quantitative tests are available, including faecal egg counts (FEC), serum ELISA and coproantigen ELISA, none can be considered a gold standard test of liver fluke infection. The accepted gold standard test for fascioliasis is the total fluke count, which is both laborious and can only be completed at post-mortem. This study aimed to compare the performance of four liver fluke diagnostic tests, against the results of a gold standard total fluke count test. Two groups of cattle were selected, 29 culled mixed age beef cows (MAC) and ten 30-month-old steers. The cattle were blood sampled and faecal sampled prior to slaughter and their whole livers recovered post slaughter at the abattoir. Liveweight was also recorded at slaughter. After collection, each liver was weighed, scored for gross pathology, then serum, faeces and livers were frozen at -20 degrees C for later analysis. Faecal egg counts and F. hepatica copro-antigen ELISA tests were completed on the faecal samples and total fluke counts were completed on the livers. Fasciola hepatica antibody concentration in serum samples were quantified using a commercial ELISA test. Poisson regression models were built to model the association between each diagnostic test and the total fluke count, and a linear regression model was built to examine the relationship between each diagnostic test and live weight at slaughter. The median fluke count was significantly higher in MAC than steers (p = 0.01), and F. hepatica eggs were present in 100% steers and 66% MAC. There was a significant effect of copro-antigen ELISA value on total fluke count (p < 0.0001), with a coproantigen ELISA value = 20.1 predicting 10 flukes and a value = 44.8 predicting 30 flukes. There was also a significant effect of FEC on total fluke count (p = 0.002) but the R-squared value for this model was lower. There was no association between liver fibrosis score or antibody ELISA test and total fluke count (p = 0.95, p = 0.73, respectively). There was a significant effect of total fluke count (p = 0.03) on liveweight at slaughter, with liveweight falling 20.4 kg for each unit increase in loge (total fluke count). There was no effect of FEC (p = 0.11), antibody ELISA (p = 0.55) or copro-antigen ELISA value (p = 0.16) on liveweight at slaughter. Taken together, these results show that the coproantigen ELISA test is the better test for estimating the true liver fluke burden and that the number of flukes in the liver has a negative effect on cattle live weights at slaughter.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Delirium diagnosis without a gold standard: Evaluating diagnostic accuracy of combined delirium assessment tools
    Moss, Stephana J.
    Hee Lee, Chel
    Doig, Christopher J.
    Whalen-Browne, Liam
    Stelfox, Henry T.
    Fiest, Kirsten M.
    PLOS ONE, 2022, 17 (04):
  • [22] Estimating diagnostic accuracy without a gold standard: A continued controversy
    Collins, John
    Albert, Paul S.
    JOURNAL OF BIOPHARMACEUTICAL STATISTICS, 2016, 26 (06) : 1078 - 1082
  • [23] THE COMPARISON OF 2 DIAGNOSTIC-TESTS IN ABSENCE OF A GOLD STANDARD
    VANROMUNDE, LKJ
    SHAW, PC
    EILERS, G
    SYSTEM SCIENCE IN HEALTH CARE, 1: INFORMATION IN HEALTH CARE SYSTEMS, 1988, 138 : 431 - 432
  • [24] COMPARISON OF DIAGNOSTIC ACCURACY OF LIVER SCANS LIVER FUNCTION TESTS AND LIVER BIOPSIES
    FERRANTE, WA
    MAXFIELD, WS
    SOUTHERN MEDICAL JOURNAL, 1968, 61 (12) : 1255 - &
  • [25] Assessment of Liver Fibrosis in Patients With Chronic Hepatitis B - Diagnostic Accuracy of Four Noninvasive Tests
    Magalhaes, Joana
    de Castro, Francisca Dias
    Carvalho, Pedro
    Leite, Silvia
    Marinho, Carla M.
    Cotter, Jose
    GASTROENTEROLOGY, 2014, 146 (05) : S258 - S258
  • [26] Continued controversy in using latent class models for estimating diagnostic accuracy without a gold standard
    Albert, Paul S.
    STATISTICS IN MEDICINE, 2021, 40 (22) : 4764 - 4765
  • [27] IMPROVED DIAGNOSTIC ACCURACY OF TRANSIENT ELASTOGRAPHY FOR CIRRHOSIS USING HISTOLOGY PLUS CLINICS AS GOLD STANDARD
    Mueller, S.
    Millonig, G.
    Stickel, F.
    Longerich, T.
    Schirmacher, P.
    Seitz, H. -K.
    JOURNAL OF HEPATOLOGY, 2010, 52 : S168 - S168
  • [28] Diagnostic Accuracy of Fine Needle Aspiration Cytology in a Breast Lump Using Histopathology as Gold Standard
    Usman, Khalid
    Nisar, Bushra
    Sajid, Muhammad
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2015, 9 (01): : 191 - 193
  • [29] Improved Diagnostic Accuracy of Transient Elastography for Cirrhosis Using Histology Plus Clinics as Gold Standard
    Mueller, Sebastian
    Millonig, Gunda
    Stickel, Felix
    Longerich, Thomas
    Schirmacher, Peter
    Seitz, Helmut-Karl
    GASTROENTEROLOGY, 2010, 138 (05) : S510 - S510
  • [30] Evaluation of diagnostic tests in the absence of a gold standard using an Anaplasma marginale field date set
    Müllner, P
    Dreher, UM
    Meli, ML
    Lutz, H
    Hofman-Lehmann, R
    Doherr, MG
    BERLINER UND MUNCHENER TIERARZTLICHE WOCHENSCHRIFT, 2005, 118 (9-10): : 416 - 422