Assessment of accuracy of liver fluke diagnostic tests using the gold standard of total worm counts

被引:0
|
作者
Dowling, A. [1 ]
Lawrence, K. E. [2 ]
Howe, L. [2 ]
Scott, I. [2 ]
Pomroy, W. E. [2 ]
机构
[1] PGG Wrightson Ltd, 1 Robin Mann Pl, Christchurch, New Zealand
[2] Massey Univ, Palmerston North, New Zealand
关键词
Fasciola hepatica; cattle; New Zealand; Gold standard test; FASCIOLA-HEPATICA INFECTION; IGG ANTIBODIES; DAIRY-COWS; CATTLE; ELISA; EFFICACY; SHEEP; MILK; TRICLABENDAZOLE; RESISTANCE;
D O I
10.1016/j.vprsr.2024.101102
中图分类号
R38 [医学寄生虫学]; Q [生物科学];
学科分类号
07 ; 0710 ; 09 ; 100103 ;
摘要
In many regions of New Zealand liver fluke is endemic, infecting most grazing ruminants, including cattle, sheep, and deer. Restricting the economic losses and welfare costs associated with liver fluke relies on accurately identifying those animals with a production limiting infection. This has proven a difficult goal and although several antemortem quantitative tests are available, including faecal egg counts (FEC), serum ELISA and coproantigen ELISA, none can be considered a gold standard test of liver fluke infection. The accepted gold standard test for fascioliasis is the total fluke count, which is both laborious and can only be completed at post-mortem. This study aimed to compare the performance of four liver fluke diagnostic tests, against the results of a gold standard total fluke count test. Two groups of cattle were selected, 29 culled mixed age beef cows (MAC) and ten 30-month-old steers. The cattle were blood sampled and faecal sampled prior to slaughter and their whole livers recovered post slaughter at the abattoir. Liveweight was also recorded at slaughter. After collection, each liver was weighed, scored for gross pathology, then serum, faeces and livers were frozen at -20 degrees C for later analysis. Faecal egg counts and F. hepatica copro-antigen ELISA tests were completed on the faecal samples and total fluke counts were completed on the livers. Fasciola hepatica antibody concentration in serum samples were quantified using a commercial ELISA test. Poisson regression models were built to model the association between each diagnostic test and the total fluke count, and a linear regression model was built to examine the relationship between each diagnostic test and live weight at slaughter. The median fluke count was significantly higher in MAC than steers (p = 0.01), and F. hepatica eggs were present in 100% steers and 66% MAC. There was a significant effect of copro-antigen ELISA value on total fluke count (p < 0.0001), with a coproantigen ELISA value = 20.1 predicting 10 flukes and a value = 44.8 predicting 30 flukes. There was also a significant effect of FEC on total fluke count (p = 0.002) but the R-squared value for this model was lower. There was no association between liver fibrosis score or antibody ELISA test and total fluke count (p = 0.95, p = 0.73, respectively). There was a significant effect of total fluke count (p = 0.03) on liveweight at slaughter, with liveweight falling 20.4 kg for each unit increase in loge (total fluke count). There was no effect of FEC (p = 0.11), antibody ELISA (p = 0.55) or copro-antigen ELISA value (p = 0.16) on liveweight at slaughter. Taken together, these results show that the coproantigen ELISA test is the better test for estimating the true liver fluke burden and that the number of flukes in the liver has a negative effect on cattle live weights at slaughter.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Estimating and comparing diagnostic tests' accuracy when the gold standard is not binary
    Obuchowski, NA
    ACADEMIC RADIOLOGY, 2005, 12 (09) : 1198 - 1204
  • [2] Evaluating accuracy of diagnostic tests with intermediate results in the absence of a gold standard
    Xu, Huiping
    Black, Michael A.
    Craig, Bruce A.
    STATISTICS IN MEDICINE, 2013, 32 (15) : 2571 - 2584
  • [3] Evaluation of the Accuracy of Diagnostic Tests From Repeated Measurements Without a Gold Standard
    Bas Engel
    Jantien Backer
    Willem Buist
    Journal of Agricultural, Biological, and Environmental Statistics, 2010, 15 : 83 - 100
  • [4] Evaluation of the Accuracy of Diagnostic Tests From Repeated Measurements Without a Gold Standard
    Engel, Bas
    Backer, Jantien
    Buist, Willem
    JOURNAL OF AGRICULTURAL BIOLOGICAL AND ENVIRONMENTAL STATISTICS, 2010, 15 (01) : 83 - 100
  • [5] Using a Web-Based Application to Define the Accuracy of Diagnostic Tests When the Gold Standard Is Imperfect
    Lim, Cherry
    Wannapinij, Prapass
    White, Lisa
    Day, Nicholas P. J.
    Cooper, Ben S.
    Peacock, Sharon J.
    Limmathurotsakul, Direk
    PLOS ONE, 2013, 8 (11):
  • [6] COMPARING DIAGNOSTIC-TESTS USING A TARNISHED GOLD STANDARD
    PHELPS, CE
    MEDICAL DECISION MAKING, 1990, 10 (04) : 324 - 324
  • [7] DIAGNOSTIC-TESTS FOR PNEUMONIA IN VENTILATED PATIENTS - PROSPECTIVE EVALUATION OF DIAGNOSTIC-ACCURACY USING HISTOLOGY AS A DIAGNOSTIC GOLD-STANDARD
    MARQUETTE, CH
    COPIN, MC
    WALLET, F
    NEVIERE, R
    SAULNIER, F
    MATHIEU, D
    DUROCHER, A
    RAMON, P
    TONNEL, AB
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1995, 151 (06) : 1878 - 1888
  • [8] Defining the true accuracy of diagnostic tests when the gold standard is imperfect using web-based application
    Limmathurotsakul, D.
    Turner, E.
    Lim, C.
    Day, N.
    Cooper, B.
    Peacock, S.
    INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2012, 16 : E398 - E398
  • [9] Significance tests for covariates in the diagnostic accuracy index of a biomarker against a continuous gold standard
    Wu, Mixia
    Sun, Xian
    Liu, Aiyi
    Peng, Chenchen
    Li, Zhaohai
    STATISTICS IN MEDICINE, 2023, 42 (22) : 4015 - 4027
  • [10] ESTIMATING DIAGNOSTIC-TEST ACCURACY USING A FUZZY GOLD STANDARD
    PHELPS, CE
    HUTSON, A
    MEDICAL DECISION MAKING, 1995, 15 (01) : 44 - 57