An enhanced approach for power quality improvement of unified power quality conditioner connected wind energy conversion system

被引:0
|
作者
Sultana, Shaziya [1 ]
Salma, Umme [2 ]
机构
[1] GITAM Deemed Univ, Dept Elect Elect & Commun Engn, Visakhapatnam, Andhra Prades, India
[2] GITAM Univ, GITAM Inst Technol, Dept Elect Elect & Commun Engn, Visakhapatnam, Andhra Prades, India
关键词
AC source; controllers; load; multi-level inverter (MLI); PQ; unified power quality conditioner; wind turbine; DESIGN; UPQC;
D O I
10.1002/oca.3178
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This manuscript proposed a hybrid system for enhancing the control strategy of a unified power quality conditioner connected to a wind energy conversion system. The proposed method is combined with honey badger algorithm (HBA) and reptile search algorithm (RSA). Therefore, it is known as the Enhanced HBA (EnHBA) technique. The key aim of the EnHBA technique is to alleviating the PQ issue exhibited in the WECS. The EnHBA approach is utilized in the non-linear load condition to find the best solutions from the available searching space in light of the goal function and generates the output. During the load variation conditions the EnHBA technique manages the loss of power, total harmonic distortion (THD), and voltage instability issue respectively. In this way, the PQ system performances improved and moreover, the various qualities decreased with the support of the EnHBA method. The EnHBA techniques' performance is validated through the MATLAB platform and the implementation is calculated with the existing techniques. The method EnHBA technique displays better outcomes in all approaches like, particle swarm optimization, whale optimization algorithm and singular spectrum analysis (SSA). The proposed method's voltage sag and swell are lowered to 14% and 15%, respectively. The THD of the En HBA method is 10%, which is lesser than other existing PSO, WOA, and SSA methods. This paper proposes an Enhanced HBA (EnHBA) technique, integrating Honey Badger Algorithm (HBA) and Reptile Search Algorithm (RSA), to improve the control strategy of a unified power quality conditioner connected to a wind energy conversion system. The EnHBA method effectively addresses power quality issues, THD, and voltage instability under load variation conditions. Validated through MATLAB, EnHBA demonstrates superior performance, reducing voltage sag and swell to 14% and 15%, respectively, and achieving THD of 10%, outperforming PSO, WOA, and SSA methods. image
引用
收藏
页数:20
相关论文
共 50 条
  • [21] Improvement of unified power quality conditioner performance with enhanced resonant control strategy
    Quoc-Nam Trinh
    Lee, Hong-Hee
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2014, 8 (12) : 2114 - 2123
  • [22] Power Quality Improvement in Distribution Networks containing Distributed Energy Resources using Unified Power Quality Conditioner
    Nair, Parvathy K.
    Reji, P.
    PROCEEDINGS OF 2015 IEEE INTERNATIONAL CONFERENCE ON POWER, INSTRUMENTATION, CONTROL AND COMPUTING (PICC), 2015,
  • [23] Enhancing the LVRT Capability of Grid Connected Wind Energy Conversion System Using Unified Power Quality Controller
    Saleh, M. A.
    Eskander, M. N.
    Amer, S.
    Nashed, Maged N. F.
    2014 IEEE TRANSPORTATION ELECTRIFICATION CONFERENCE AND EXPO (ITEC) ASIA-PACIFIC 2014, 2014,
  • [24] Transformerless Cross Phase Connected Unified Power Quality Conditioner
    Raghunath, Sruthi
    Kumar, P. Venkatesh
    PROCEEDINGS OF 2013 INTERNATIONAL CONFERENCE ON CIRCUITS, POWER AND COMPUTING TECHNOLOGIES (ICCPCT 2013), 2013, : 450 - 455
  • [25] A New Unified Power Quality Conditioner for Grid Integration of PV System and Power Quality Improvement Feature Distribution System
    Vodapalli, Prakash
    Reddy, T. Rama Subba
    Kalyani, S. Tara
    2015 INTERNATIONAL CONFERENCE ON ELECTRICAL, ELECTRONICS, SIGNALS, COMMUNICATION AND OPTIMIZATION (EESCO), 2015,
  • [26] Improvement of Power Quality of Wind-FC Energy power hybrid system connected to network
    Arezki, S.
    Boudour, M.
    3RD INTERNATIONAL SYMPOSIUM ON ENVIRONMENTAL FRIENDLY ENERGIES AND APPLICATIONS (EFEA 2014), 2014,
  • [27] Transformerless cross phase connected Unified Power Quality Conditioner
    Raghunath, Sruthi
    Kumar, P. Venkatesh
    Proceedings of IEEE International Conference on Circuit, Power and Computing Technologies, ICCPCT 2013, 2013, : 450 - 455
  • [28] Performance Improvement of a Distributed Generation System Using Unified Power Quality Conditioner
    Sarita Samal
    Prakash Kumar Hota
    Prasanta Kumar Barik
    Technology and Economics of Smart Grids and Sustainable Energy, 5
  • [29] Adaptive unified power quality conditioner for emproving power quality
    Tey, LH
    So, PL
    Chu, YC
    IPEC 2003: PROCEEDINGS OF THE 6TH INTERNATIONAL POWER ENGINEERING CONFERENCE, VOLS 1 AND 2, 2003, : 52 - 57
  • [30] Performance Improvement of a Distributed Generation System Using Unified Power Quality Conditioner
    Samal, Sarita
    Hota, Prakash Kumar
    Barik, Prasanta Kumar
    TECHNOLOGY AND ECONOMICS OF SMART GRIDS AND SUSTAINABLE ENERGY, 2020, 5 (01):