Optical Methods for Optimizing Fluorescence Imaging Field of View and Image Quality in Surgical Guidance Procedures

被引:0
|
作者
Seo, Jeongmin [1 ,2 ,3 ]
Park, Jina [1 ,2 ,3 ]
Yoon, Kicheol [1 ,2 ,3 ]
Lee, Sangyun [4 ]
Kim, Minchan [3 ]
Ryu, Seung Yeob [3 ,5 ]
Kim, Kwang Gi [3 ,5 ,6 ]
机构
[1] Gachon Univ, Coll Med, Premed Course, 8-13 3 Dokjom Ro, Incheon ] 21565, South Korea
[2] Gachon Univ, Coll Med, Dept Med, 8-13 3 Dokjom Ro, Incheon 21565, South Korea
[3] Gachon Univ, Med Devices R&D Ctr, Gil Med Ctr, 21 774 Beon Gil, Incheon 21565, South Korea
[4] Dongnam Hlth Univ, Dept Radiol Sci, 50 Cheoncheon Ro 74 Gil, Suwon 16328, South Korea
[5] Gachon Univ, Dept Biohlth & Med Engn Major & Biomed Engn, 1342 Seongnamdaero, Seongnam 13120, South Korea
[6] Gachon Univ, Gachon Adv Inst Hlth Sci & Technol GAIHST, Dept Hlth Sci & Technol, 38-13 3 Dokjom Ro, Incheon 21565, South Korea
关键词
LED; beam mirror; linear polarized filter; light reflection removal; fluorescence emission;
D O I
10.3390/diagnostics14171996
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Cancer surgery is aimed at complete tumor resection and accurate lymph node detection. However, numerous blood vessels are distributed within the tumor, and the colors of the tumor, blood vessels, and lymph nodes are similar, making observations with the naked eye difficult. Therefore, tumors, blood vessels, and lymph nodes can be monitored via color classification using an operating microscope to induce fluorescence emission. However, as the beam width of the LED required to induce fluorescence emission is narrow and the power loss of the beam is significant at a certain working distance, there are limitations to inducing fluorescence emission, and light reflection occurs in the observation image, obstructing the view of the observation area. Therefore, the removal of reflected light is essential to avoid missing the diagnosis of the lesion under observation. This paper proposes the use of a beam mirror and polarizing filter to increase the beam width and beam intensity. The refraction and reflection effects of the beam were utilized using the beam mirror, and the rotation angle of the polarizing filter was adjusted to remove light reflection. Consequently, the minimum beam power using the beam mirror was 10.9 mW, the beam width was doubled to 40.2 degrees, and more than 98% of light reflection was removed at 90 degrees and 270 degrees. With light reflection effectively eliminated, clear observation of lesions is possible. This method is expected to be used effectively in surgical, procedural, and diagnostic departments.
引用
收藏
页数:20
相关论文
共 50 条
  • [41] Cloud bottom height estimation methods for optical imaging terminal guidance
    Liang, Shuai
    Liu, Meng
    Wang, Zhongyang
    Zhang, Tianxu
    MIPPR 2019: PATTERN RECOGNITION AND COMPUTER VISION, 2020, 11430
  • [42] Hybrid Surgical Guidance: Does Hardware Integration of γ- and Fluorescence Imaging Modalities Make Sense?
    KleinJan, Gijs H.
    Hellingman, Daan
    van den Berg, Nynke S.
    van Oosterom, Matthias N.
    Hendricksen, Kees
    Horenblas, Simon
    Olmos, Renato A. Valdes
    van Leeuwen, Fijs W. B.
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58 (04) : 646 - 650
  • [43] Large field-of-view optical microscopic imaging technology
    Wang Y.-Q.
    Lin F.-R.
    Hu R.
    Liu L.-W.
    Qu J.-L.
    Chinese Optics, 2022, 15 (06) : 1194 - 1210
  • [44] A small field of view camera for hybrid gamma and optical imaging
    Lees, J. E.
    Bugby, S. L.
    Bhatia, B. S.
    Jambi, L. K.
    Alqahtani, M. S.
    McKnight, W. R.
    Ng, A. H.
    Perkins, A. C.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [45] Endoscopic optical coherence tomography imaging for surgical diagnostics and guidance in the gastrointestinal tract
    Boppart, SA
    Li, XD
    Pitris, C
    Stamper, DL
    Brezinski, ME
    Fujimoto, JG
    BIOMEDICAL DIAGNOSTIC, GUIDANCE, AND SURGICAL-ASSIST SYSTEMS, 1999, 3595 : 158 - 164
  • [46] 2 NEW METHODS OF IMPROVING OPTICAL IMAGE QUALITY
    BOWMAN, MJ
    APPLIED OPTICS, 1968, 7 (11): : 2280 - &
  • [47] Image quality improvement for optical imaging interferometric microscopy
    Dey, P.
    Neumann, A.
    Brueck, S. R. J.
    OPTICS EXPRESS, 2021, 29 (23) : 38415 - 38428
  • [48] Quantitative Fluorescence Imaging Enabled by Spatial Frequency Domain Optical-Property Mapping in the Sub-diffusive Regime for Surgical Guidance
    Sibai, Mira
    Veilleux, Israel
    Elliott, Jonathan T.
    Leblond, Frederic
    Roberts, David W.
    Wilson, Brian C.
    MOLECULAR-GUIDED SURGERY: MOLECULES, DEVICES, AND APPLICATIONS, 2015, 9311
  • [49] Effects of sampling strategy on image quality in noncontact panoramic fluorescence diffuse optical tomography for small animal imaging
    Zhang, Xiaofeng
    Badea, Cristian
    OPTICS EXPRESS, 2009, 17 (07): : 5125 - 5138
  • [50] Impact of the optical depth of field on cytogenetic image quality
    Qiu, Yuchen
    Chen, Xiaodong
    Li, Yuhua
    Zheng, Bin
    Li, Shibo
    Chen, Wei R.
    Liu, Hong