Analysis of a multicenter registry on evaluation of transit-time flow in coronary artery disease surgery

被引:1
|
作者
Laali, Mojgan [1 ]
Bouchot, Olivier [2 ]
Fouquet, Olivier [3 ]
Maureira, Pablo [4 ]
Verhoye, Jean-Philippe [5 ]
Corbi, Pierre [6 ]
David, Charles-Henri [7 ]
D'Alessandro, Cosimo [1 ]
Demondion, Pierre [1 ]
Lebreton, Guillaume [1 ]
Leprince, Pascal [1 ]
机构
[1] Sorbonne Univ, Grp Hosp Pitie Salpetriere, AP HP, Inst Cardiol,Thorac & Cardiovasc Surg Dept, Paris, France
[2] Hosp Ctr Univ, Cardiothorac & Vasc Surg Unit, Dijon, France
[3] Angers Univ Hosp Ctr, Cardiac Surg, Angers, France
[4] Univ Nancy, Hosp Ctr, Cardiac Surg Unit, Nancy, France
[5] Univ Rennes, Hosp Ctr, Thorac & Cardiovasc Surg Dept, Rennes, France
[6] Univ Poitiers, Hosp Ctr, Cardiothorac & Vasc Surg Unit, Poitiers, France
[7] CHU Nantes, Cardiothorac & Vasc Surg Unit, Nantes, France
来源
JTCVS OPEN | 2023年 / 16卷
关键词
multicenter registry; coronary artery surgery; transit-time flow measurement; GRAFT PATENCY;
D O I
10.1016/j.xjon.2023.08.023
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
<bold>Objective: </bold>The Evaluation of Transit-Time Flow in Coronary Artery Disease Surgery (EFCAD) registry aims to assess the influence of transit-time flow measurement (TTFM) in daily practice. <bold>Methods: </bold>EFCAD is a prospective, multicenter study involving 9 centers performing TTFM during isolated coronary artery bypass grafting. Primary end point was occurrence and risk factors of major adverse cardiac events, including perioperative myocardial infarction, urgent postoperative coronary angiogram and/or revascularization, and hospital mortality. Secondary end points were rate of graft revision during surgery and factors affecting graft flow. We respected the limit values set by the experts: mean graft flow >15 mL/minute and pulsatility index <= 5. <bold>Results: </bold>Between May 2017 and March 2021, 1616 patients were registered in the EFCAD database. After review, 1414 were included for analyses. Of those, 1176 were eligible for primary end point analysis. Graft revision, mainly due to inadequate TTFM values, occurred in 2% (29 patients). The primary end point occurred in 46 (3.9%) patients, and it was related with left anterior descending artery graft flow <= 15 mL/minute (odds ratio, 3.64; P < .001). Graft flow was related with number of grafts (3 vs 1-2, beta = -1.6; 4-6 vs 1-2, beta = -4.1; P < .001; beta > 0 indicates higher flow), and graft origin (aorta vs Y, beta = 9.2; in situ left internal thoracic artery vs Y, beta = 3.2; in situ right internal thoracic artery vs Y, beta = 2.3; P < .001). <bold>Conclusions: </bold>Data from EFCAD study suggest that TTFM is reliable to evaluate graft flow, and acceptance of inadequate flow on left anterior descending artery anastomosis influence postoperative outcomes. In our opinion, TTFM assessment should be routinely used in coronary artery bypass procedures, even if interpretation depends on learning curves.
引用
收藏
页码:401 / 418
页数:18
相关论文
共 50 条
  • [31] Predictive value of intraoperative transit-time flow measurement for short-term graft patency in coronary surgery
    Di Giammarco, Gabriele
    Pano, Marco
    Cirmeni, Sergio
    Pelini, Piero
    Vitolla, Giuseppe
    Di Mauro, Michele
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2006, 132 (03): : 468 - 474
  • [32] EVALUATION OF MEAN TRANSIT-TIME - REPLY
    HUDSON, M
    NINAN, TK
    RUSSEL, G
    RESPIRATORY MEDICINE, 1993, 87 (04) : 320 - 320
  • [33] VALUE OF MINIMAL CARDIAC TRANSIT-TIME FOR EVALUATION OF CARDIAC-FUNCTION IN CORONARY HEART-DISEASE
    LOSSE, B
    SCHICHA, H
    BECKER, V
    BOTH, A
    SEIPEL, L
    FEINENDEGEN, LE
    LOOGEN, F
    ZEITSCHRIFT FUR KARDIOLOGIE, 1976, 65 (09): : 813 - 813
  • [34] The importance of perioperative flow evaluation and prevention of steal syndrome in arteriovenous fistula surgery using transit-time flow measurement
    Colak, Abdurrahim
    Jalalzai, Izatullah
    INDIAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2023, 10 (02) : 104 - 108
  • [35] THE ALGORITHM FOR USING TRANSIT-TIME FLOW MEASUREMENT AND HIGH-RESOLUTION EPICARDIAL ULTRASOUND FOR INTRAOPERATIVE GRAFTS ASSESSMENT DURING CORONARY ARTERY BYPASS SURGERY
    Sigaev, I. Yu
    Keren, M. A.
    Slivneva, I., V
    Shonia, Z. D.
    Marapov, D., I
    KARDIOLOGIYA, 2022, 62 (08) : 3 - 10
  • [36] EXPERIMENTAL AND CLINICAL-STUDIES ON MEAN TRANSIT-TIME OF CORONARY CIRCULATION - WITH REFERENCE TO THE EFFECT OF NG ON CORONARY CONTRAST TRANSIT-TIME
    OHTA, S
    GENDA, A
    OIWAKE, H
    UESAKA, T
    TANAKA, N
    MONJI, T
    TAKEDA, R
    JAPANESE CIRCULATION JOURNAL-ENGLISH EDITION, 1980, 44 (08): : 619 - 619
  • [37] OROCECAL TRANSIT-TIME IN HEALTH AND DISEASE
    GILMORE, IT
    GUT, 1990, 31 (03) : 250 - 251
  • [38] Transit-time flow predicts outcomes in coronary artery bypass graft patients: a series of 1000 consecutive arterial grafts
    Kieser, Teresa Mary
    Rose, Sarah
    Kowalewski, Ryszard
    Betenkie, Israel
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2010, 38 (02) : 155 - 161
  • [39] The Role of Color Doppler Ultrasonography in the Perioperative Period of Coronary Artery Bypass Grafting: Comparison with Transit-Time Flow Measurement
    Gao, Junxue
    Zhao, Zhou
    Zhu, Jiaan
    Tian, Hui
    Liu, Yuejie
    CARDIOLOGY, 2021, 146 (05) : 583 - 590
  • [40] Intraoperative assessment of coronary artery bypass graft: Transit-time flowmetry versus angiography
    Shin, H
    Yozu, R
    Mitsumaru, A
    Iino, Y
    Hashizume, K
    Matayoshi, T
    Kawada, S
    ANNALS OF THORACIC SURGERY, 2001, 72 (05): : 1562 - 1565