Feasibility of identifying proliferative active bone marrow with fat fraction MRI and multi-energy CT

被引:1
|
作者
Lawless, M. [1 ]
Byrns, K. [2 ]
Bednarz, B. P. [3 ]
Meudt, J. [4 ]
Shanmuganayagam, D. [4 ]
Shah, J. [5 ]
McMillan, A. [6 ]
Li, K. [3 ]
Pirasteh, A. [6 ]
Miller, J. [1 ]
机构
[1] Univ Wisconsin Madison, Dept Human Oncol, 600 Highland Ave, Madison, WI 53792 USA
[2] St Lukes Radiat Oncol Associates, 915 E 1st St, Duluth, MN 55805 USA
[3] Univ Wisconsin Madison, Dept Med Phys, 1111 Highland Ave, Madison, WI 53705 USA
[4] Univ Wisconsin Madison, Dept Anim & Dairy Sci, 1675 Observ Dr, Madison, WI 53706 USA
[5] Siemens Healthineers, 221 Gregson Dr, Cary, NC 27511 USA
[6] Univ Wisconsin Madison, Dept Radiol, 600 Highland Ave, Madison, WI 53792 USA
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2024年 / 69卷 / 13期
关键词
active bone marrow; multi-energy CT; fat fraction MRI; TOTAL-BODY IRRADIATION; MODULATED RADIATION-THERAPY; ACUTE NONLYMPHOBLASTIC LEUKEMIA; POSITRON-EMISSION-TOMOGRAPHY; ACUTE HEMATOLOGIC TOXICITY; GUIDED TOTAL-MARROW; CONCURRENT CHEMOTHERAPY; CERVICAL-CANCER; HELICAL TOMOTHERAPY; PELVIC RADIATION;
D O I
10.1088/1361-6560/ad58a0
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. Active bone marrow (ABM) can serve as both an organ at risk and a target in external beam radiotherapy. 18F-fluorothymidine (FLT) PET is the current gold standard for identifying proliferative ABM but it is not approved for human use, and PET scanners are not always available to radiotherapy clinics. Identifying ABM through other, more accessible imaging modalities will allow more patients to receive treatment specific to their ABM distribution. Multi-energy CT (MECT) and fat-fraction MRI (FFMRI) show promise in their ability to characterize bone marrow adiposity, but these methods require validation for identifying proliferative ABM. Approach. Six swine subjects were imaged using FFMRI, fast-kVp switching (FKS) MECT and sequential-scanning (SS) MECT to identify ABM volumes relative to FLT PET-derived ABM volumes. ABM was contoured on FLT PET images as the region within the bone marrow with a SUV above the mean. Bone marrow was then contoured on the FFMRI and MECT images, and thresholds were applied within these contours to determine which threshold produced the best agreement with the FLT PET determined ABM contour. Agreement between contours was measured using the Dice similarity coefficient (DSC). Main results. FFMRI produced the best estimate of the PET ABM contour. Compared to FLT PET ABM volumes, the FFMRI, SS MECT and FKS MECT ABM contours produced average peak DSC of 0.722 +/- 0.080, 0.619 +/- 0.070, and 0.464 +/- 0.080, respectively. The ABM volume was overestimated by 40.51%, 97.63%, and 140.13% by FFMRI, SS MECT and FKS MECT, respectively. Significance. This study explored the ability of FFMRI and MECT to identify the proliferative relative to ABM defined by FLT PET. Of the methods investigated, FFMRI emerged as the most accurate approximation to FLT PET-derived active marrow contour, demonstrating superior performance by both DSC and volume comparison metrics. Both FFMRI and SS MECT show promise for providing patient-specific ABM treatments.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Active Bone Marrow Delineation in a Swine Model Via Proton Density Fat Fraction MRI and Multi-Energy CT
    Coleman, D.
    Meudt, J.
    Shanmuganayagam, D.
    Shah, J.
    McMillan, A.
    Pirasteh, A.
    Miller, J.
    Bednarz, B.
    Lawless, M.
    MEDICAL PHYSICS, 2022, 49 (06) : E513 - E514
  • [2] Identifying Active Marrow Using Dual Energy CT Multi-Material Decomposition
    Lyu, Q.
    Miller, J.
    Savjani, R.
    Lawless, M.
    McKenzie, E.
    Sheng, K.
    MEDICAL PHYSICS, 2020, 47 (06) : E378 - E378
  • [3] Quantification of Spinal Bone Marrow Fat Fraction Using Three-Material Decomposition Technique on Dual-Energy CT: A Feasibility Study
    Li, B.
    Hua, N.
    Li, J.
    Andreu-arasa, V.
    Lebedis, C.
    Anderson, S.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [4] Fat Fraction Measurements Using a Three-Material Decomposition Dual-Energy CT Technique Accounting for Bone Minerals: Evaluation in a Bone Marrow Phantom Using MRI as Reference
    Li, Baojun
    Hua, Ning
    Li, Janelle
    Andreu-Arasa, V. Carlota
    LeBedis, Christina
    Anderson, Stephan W.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2022, 218 (03) : 553 - 554
  • [5] Measurement of vertebral bone marrow proton density fat fraction in children using quantitative water–fat MRI
    Stefan Ruschke
    Amber Pokorney
    Thomas Baum
    Holger Eggers
    Jeffrey H. Miller
    Houchun H. Hu
    Dimitrios C. Karampinos
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2017, 30 : 449 - 460
  • [6] Multi-energy CT with Triple X-ray Beams: A Feasibility Animal Study
    Ren, Liqiang
    Rajendran, Kishore
    Fletcher, Joel G.
    Allmendinger, Thomas
    Halaweish, Ahmed
    Schmidt, Bernhard
    Flohr, Thomas
    McCollough, Cynthia H.
    Yu, Lifeng
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
  • [7] Quantitation of Bone Marrow Fat in Long Bones of Mice Using MRI or μCT.
    Adams, D. J.
    Pinz, I.
    Praeda, M.
    Canalis, E.
    Troiano, N.
    Horowitz, M. C.
    Rosen, C.
    JOURNAL OF BONE AND MINERAL RESEARCH, 2008, 23 : S409 - S409
  • [8] Measurement of vertebral bone marrow proton density fat fraction in children using quantitative water-fat MRI
    Ruschke, Stefan
    Pokorney, Amber
    Baum, Thomas
    Eggers, Holger
    Miller, Jeffrey H.
    Hu, Houchun H.
    Karampinos, Dimitrios C.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2017, 30 (05) : 449 - 460
  • [9] Dual energy CT and research of the bone marrow edema: Comparison with MRI imaging
    Saba, Luca
    De Filippo, Massimo
    Saba, Francesco
    Fellini, Federica
    Marcy, Pierre-Yves
    Dagan, Robert
    Voituriez, Philippe
    Aelvoet, Jacques
    Klotz, Gerard
    Bernard, Roland
    Salinesi, Valerie
    Agostini, Serge
    INDIAN JOURNAL OF RADIOLOGY AND IMAGING, 2019, 29 (04): : 386 - 390
  • [10] Quantifying Bone Marrow Fat Fraction and Iron by MRI for Distinguishing Aplastic Anemia from Myelodysplastic Syndromes
    Zeng, Zhaolong
    Ma, Xiangzheng
    Guo, Yifan
    Ye, Baodong
    Xu, Maosheng
    Wang, Wei
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 54 (06) : 1754 - 1760