Simplified Modeling Method for Prefabricated Shear Walls Considering Sleeve Grouting Defects

被引:0
|
作者
Wang, Yanan [1 ]
Wang, Hongchen [1 ]
Wang, Fujie [1 ]
机构
[1] Xian Technol Univ, Sch Civil & Architecture Engn, Xian 710021, Peoples R China
关键词
sleeve grouting defects; prefabricated shear wall; equivalent constitutive relationship; numerical simulation; seismic performance; BOND BEHAVIOR; PERFORMANCE; TENSILE; CONNECTION; SPLICE; BAR;
D O I
10.3390/buildings14061813
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The sleeve grouting connection is the most common form of vertical connection for prefabricated shear walls. However, during construction, this type of connection is prone to defects such as insufficient anchorage length of reinforcement, deviation of reinforcement, and insufficient amount of sleeve grouting, which significantly impact the integrity and seismic performance of the prefabricated shear wall structure. The finite element analysis of the prefabricated shear wall with sleeve grouting connection is still based on solid element modeling. This method has the disadvantages of complex models and low computational efficiency. In this paper, a simplified modeling method for prefabricated shear walls considering sleeve grouting defects was proposed to address this issue. Firstly, the equivalent constitutive relationship of the sleeve grouting defect connector was constructed based on the uniaxial tensile test of the existing sleeve grouting defect connector, and the T3D2 element was used to simulate the sleeve grouting connector. Then, the mechanical behavior of the horizontal joint between the shear wall and the foundation beam was simulated by the cohesive force model, and the prefabricated shear wall models with sleeve grouting defects were established. The accuracy of the simplified modeling method was verified by comparing the experimental results and numerical simulation results of the seismic performance of the prefabricated shear wall with sleeve grouting defects. The results showed that the hysteresis curve, skeleton curve, and failure mode of the numerical simulation were in good agreement with the test results. However, the stiffness of the concrete degenerated rapidly due to the apparent development of plastic-damaged concrete, which made the falling section of the hysteresis curve of the numerical simulation different from that of the test. The proposed simplified modeling method can be further applied to the performance study of prefabricated shear walls with sleeve grouting defects and can provide a reference for structural performance evaluation, design optimization, and construction quality control to a certain extent.
引用
收藏
页数:18
相关论文
共 43 条
  • [41] Applying a 2D Variational Rigid Block Modeling Method to Rubble Stone Masonry Walls Considering Uncertainty in Material Properties
    Wang, Qianqing
    Haindl, Mathias
    dos Santos, Ketson R. M.
    Beyer, Katrin
    INTERNATIONAL JOURNAL OF ARCHITECTURAL HERITAGE, 2024,
  • [42] Numerical simulation on shear performance and conversion method considering height to width ratio effect of cold-formed steel framing walls using OpenSees
    Wu F.
    Li Y.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2023, 44 (07): : 225 - 235
  • [43] A novel modeling method to study compressive behaviors of 3D braided composites considering effects of fiber breakage and waviness defects
    Liu, Tao
    Wen, Danyang
    Shen, Qingliang
    Liang, Junhao
    Chen, Yue
    Fang, Zhi
    Zhang, Mengyuan
    Cheng, Siqi
    Gao, Yuxuan
    Gao, Xingzhong
    COMPOSITE STRUCTURES, 2024, 340