Short-time coherence between repeated room impulse response measurements

被引:0
|
作者
Prawda, Karolina [1 ]
Schlecht, Sebastian J. [1 ,2 ]
Valimaki, Vesa [1 ]
机构
[1] Aalto Univ, Dept Informat & Commun Engn, Acoust Lab, FI-02150 Espoo, Finland
[2] Aalto Univ, Media Lab, Dept Art & Media, FI-02150 Espoo, Finland
来源
关键词
MLS MEASUREMENTS; COEFFICIENT;
D O I
10.1121/10.0028172
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Room impulse responses (RIRs) vary over time due to fluctuations in atmospheric temperature, humidity, and pressure. This can introduce uncertainties in room transfer-function measurements, which are challenging to account for. Previous methods of identification and compensation of time variance focus on systematic atmospheric changes and do not apply to subtle discrepancies in RIRs. In this work, we address this problem by proposing a model of short-time coherence between repeated RIR measurements as an indicator of time-frequency similarity and as a measure of time-variance-induced changes in RIRs. Atmospheric changes cause fluctuation in sound speed, which, in turn, results in variation in the time-of-arrival of sound reflections following a Generalized Wiener process. We show that the short-time coherence decreases exponentially with the reflection-path length and propose volatility as a single model parameter determining the coherence decay rate. The proposed model is validated on simulations and measurements, showing applicability in indoor scenarios. The method reliably estimates volatility of 10(-6 )s/s as measured under laboratory conditions. We exemplify the utility of short-time coherence loss by predicting the high-frequency energy loss stemming from RIR averaging. The proposed method is useful in assessing the uncertainty of RIR measurements, especially when repeated measurements are compared or averaged.
引用
收藏
页码:1017 / 1028
页数:12
相关论文
共 50 条
  • [32] SHORT-TIME RESPONSE CHARACTERISTICS OF SALBUTAMOL IN INFANTS WITH BRONCHOPULMONARY DISEASES
    KRAEMER, R
    BIRRER, P
    SENNHAUSER, FH
    SCHONI, MH
    EUROPEAN JOURNAL OF CLINICAL PHARMACOLOGY, 1988, 34 (04) : 339 - 342
  • [33] ON THE SHORT-TIME BEHAVIOR OF THE DIPOLAR SIGNAL IN RELAXATION MEASUREMENTS BY THE PULSE METHOD
    EMID, S
    KONIJNENDIJK, J
    SMIDT, J
    PINES, A
    PHYSICA B & C, 1980, 100 (02): : 215 - 218
  • [34] SHORT-TIME RESPONSE TO PULP CAPPING MATERIAL ON RAT MOLARS
    MALLET, JP
    TRILLER, M
    JOURNAL OF DENTAL RESEARCH, 1986, 65 (04) : 565 - 565
  • [35] Differences between repeated lipid profile measurements in a tertiary hospital over a short time period
    Porat, Or
    Kaplan, Marriele
    Atlibenkin, Smadar
    Hasson-Gilad, Dalia
    Karban, Amir
    Zalts, Ronen
    LIPIDS IN HEALTH AND DISEASE, 2024, 23 (01)
  • [36] Differences between repeated lipid profile measurements in a tertiary hospital over a short time period
    Or Porat
    Marriele Kaplan
    Smadar Atlibenkin
    Dalia Hasson-Gilad
    Amir Karban
    Ronen Zalts
    Lipids in Health and Disease, 23
  • [37] Impulse response measurements using optical low coherence reflectometry with tunable source
    Engin, D.
    Eyal, A.
    Salvadore, R.
    Tur, M.
    Tong, X.
    2006 OPTICAL FIBER COMMUNICATION CONFERENCE/NATIONAL FIBER OPTIC ENGINEERS CONFERENCE, VOLS 1-6, 2006, : 651 - 653
  • [38] Short-time thermoelastic contributions to picosecond-time scale reflectivity measurements of metals
    Richardson, CJK
    Spicer, JB
    APPLIED PHYSICS LETTERS, 2002, 80 (16) : 2895 - 2897
  • [39] Common Image Source Search for Multiple Spatial Room Impulse Response Measurements
    Puomio, Otto
    Lokki, Tapio
    2021 IMMERSIVE AND 3D AUDIO: FROM ARCHITECTURE TO AUTOMOTIVE (I3DA), 2021,
  • [40] Short-time series optical coherence tomography angiography and its application to cutaneous microvasculature
    Wang, Qiang
    Gong, Peijun
    Cense, Barry
    Sampson, David D.
    BIOMEDICAL OPTICS EXPRESS, 2019, 10 (01): : 293 - 307