A gas spark switch electrode impact pressure test platform

被引:0
|
作者
Luo, Cheng [1 ]
Zhang, Yongmin [1 ]
Lu, Yong [1 ]
Zhang, Shaojie [2 ]
Wang, Pengfei [2 ]
Wang, Haodong [2 ]
Liu, Zhi [2 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian, Shaanxi, Peoples R China
[2] Xi An Jiao Tong Univ, Sch Elect Engn, Xian, Shaanxi, Peoples R China
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2024年 / 95卷 / 08期
关键词
DISCHARGE;
D O I
10.1063/5.0206865
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The discharge arc of a high-current gas spark switch has a strong mechanical effect on the electrode and adjacent objects. The measurement of this mechanical effect on the electrode plays a very important role in switch design and the theoretical study of spark discharge. However, in traditional stress measurement systems, the spatial electromagnetic interference caused by the discharge and the high electrode voltage affects the measurement accuracy and can even damage the experimental instrument. In this paper, an electrode impact stress measurement system based on PVDF piezoelectric film is designed to measure the electrode stress under a strong spatial electromagnetic field and high voltage. The experimental results show that the system can measure the impact pressure of high-voltage and high-current gas spark switch electrodes. The starting time of the stress measurement waveform shows that the shock to the electrode is formed in the initial stage of current buildup. The measured results clearly show the high magnetic field force component in the electrode impact pressure waveform. The shock waveforms induced by different pulse capacitor values, breakdown voltages, and loads are examined. It is found that the shock stress waveforms applied to the electrodes are affected by the peak value of the current, dI/dt, and the discharge duration.
引用
收藏
页数:12
相关论文
共 50 条
  • [41] Electromagnetic modelling of high pressure spark gap peaking switch
    Parekh, Mrunal G.
    Bindu, S.
    Mangalvedekar, H. A.
    2012 16TH INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC LAUNCH TECHNOLOGY (EML), 2012,
  • [42] Evaluation of switch jitter in a high pressure coaxial spark gap
    James, C.
    Dickens, J.
    Holt, S.
    Kristiansen, M.
    2007 IEEE PULSED POWER CONFERENCE, VOLS 1-4, 2007, : 564 - 567
  • [43] Pressure gas switch with concentric nozzle
    Heilmann, P
    ZEITSCHRIFT DES VEREINES DEUTSCHER INGENIEURE, 1933, 77 : 792 - 793
  • [44] Review of Electrode Erosion in a Spark Gap Switch Under Large Pulsed Currents
    Wu J.
    Ding W.
    Han R.
    Qiu A.
    Gaodianya Jishu/High Voltage Engineering, 2021, 47 (09): : 3367 - 3379
  • [45] An OECT Electrode Platform for Gas Sensor Applications
    Slauf, Josef
    Sima, Karel
    Reboun, Jan
    2021 44TH INTERNATIONAL SPRING SEMINAR ON ELECTRONICS TECHNOLOGY (ISSE), 2021,
  • [46] Experimental investigation of gas spark switch features on pulse repetition rate
    Peng, Jianchang
    Sun, Xu
    She, Xiyuan
    Wang, Ying
    Qiu, Ge
    Lin, Qiang
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2014, 26 (06):
  • [47] Experimental Study on Multigap Multichannel Gas Spark Closing Switch for LTD
    Liu, Xuandong
    Sun, Fengju
    Liang, Tianxue
    Jiang, Xiaofeng
    Zhang, Qiaogen
    Qiu, Aici
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2009, 37 (07) : 1318 - 1323
  • [48] Simulation and test of the thermal behavior of pressure switch
    Liu, Yifang
    Chen, Daner
    Zhang, Yao
    Dai, Tingting
    MODERN PHYSICS LETTERS B, 2018, 32 (11):
  • [49] The effect of intermediate electrode on pseudo-spark switch performance with high repetition rate
    Hamad, B. H.
    Ahmad, A. K.
    ELECTRICAL ENGINEERING, 2022, 104 (02) : 697 - 703
  • [50] The effect of intermediate electrode on pseudo-spark switch performance with high repetition rate
    B. H. Hamad
    A. K. Ahmad
    Electrical Engineering, 2022, 104 : 697 - 703