Simultaneous determination of 13 biogenic amines and their metabolites in liquid fermented food by HPLC-QTRAP-MS without derivatization

被引:0
|
作者
Cai, Qiong [1 ,2 ]
Li, Xiaoqin [1 ,2 ]
Ran, Zongqin [1 ]
Li, Shan [1 ]
Shi, Qinfang [1 ]
Zhang, Jie [2 ]
Gao, Ling [3 ]
机构
[1] Chongqing Acad Metrol & Qual Inspect, Chongqing 401121, Peoples R China
[2] Chongqing Technol & Business Univ, Coll Environm & Resources, Chongqing 400067, Peoples R China
[3] Southwest Univ Sci & Technol, Sch Mat & Chem, Mianyang 621010, Sichuan, Peoples R China
关键词
Biogenic amines; Metabolites; HPLC-QTRAP-MS; Liquid fermented food; MRM-IDA-EPI; Without derivatization; SOLID-PHASE EXTRACTION; MEAT-PRODUCTS; CHROMATOGRAPHY; WINES; FISH; HISTAMINE; MS/MS;
D O I
10.1016/j.microc.2024.111659
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Biogenic amines and their metabolites (BAs) are among the most frequently detected compounds in liquid fermented foods, raising significant concerns about the potential risks they pose. To rapidly and selectively determine BAs, this study proposed and validated a method for the simultaneous determination of 13 BAs in liquid fermented foods using high performance liquid chromatography-triple quadrupole/linear ion trap mass spectrometry (HPLC-QTRAP-MS) without derivatization. The simultaneous separation and determination of histamine (HIS), tyramine (TYR), putrescine (PUT), octopamine (OCT), 2-phenylethylamine (2-PHE), dopamine (DOP), spermidine (SPD), epinephrine (EPI), agmatine (AGM), 5-hydroxytryptamine (5-HYD), tryptamine (TRY), L-noradrenaline (L-NOR), cadaverine (CAD) were achieved using a Waters Atlantis Premier BEH Z-HILIC (1.7 mu m particle size, 100 mm x 2.1 mm id) column with a mobile phase consisting of water (containing 0.025 % formic acid) and acetonitrile (containing 0.1 % formic acid). The analysis of target compounds was performed with electrospray ionization (ESI) in positive ion mode, multiple reaction monitoring (MRM), information dependent acquisition (IDA), enhanced product ion (EPI), and multi-step mode analysis combined with EPI library searching. To enhance the extraction efficiency of BAs, factors such as extraction solvent, filter membranes, extraction methods, pH, oscillation speed, time and temperature were systematically investigated. The results demonstrated that the method exhibited low limits of detection (LOD) and quantification (LOQ), ranging from 0.05 to 2.00 mu g/L and 0.16 to 6.60 mu g/L, respectively. The method also showed satisfactory reproducibility, with intra-day and inter-day relative standard deviations ranging from 0.90 % to 3.80 % and 2.65 % to 8.27 %, respectively. Additionally, it had a broad linear range from 0.05 to 200.00 mu g/L with excellent linearity (R>0.99) and an average recovery rate between 65.68 % and 115.14 %. Overall, the results demonstrated that the established method was convenient to operate, offered a short analysis time, and achieved high accuracy and sensitivity. It met the qualitative and quantitative requirements for detecting 13 BAs in liquid fermented food, thus providing strong technical support for BAs detection.
引用
收藏
页数:13
相关论文
共 43 条
  • [42] DETERMINATION OF PROSTAGLANDINS-E2, F2-ALPHA AND THEIR 15-KETO-13, METABOLITES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY (HPLC) WITH SUBSEQUENT QUANTITATION BY GC-MS
    HUBBARD, WC
    WATSON, JT
    CARR, K
    BOERTH, R
    OATES, JA
    FEDERATION PROCEEDINGS, 1976, 35 (03) : 298 - 298
  • [43] Simultaneous determination of five triterpenic acids in four Corydalis herb medicines by reversed-phase high performance liquid chromatography-fluorescence-mass spectrometer (RP-HPLC-FLD-MS) based on pre-column derivatization
    Ma, Tao
    Hu, Na
    Zhang, Qiulong
    Ding, Chenxi
    Che, Guodong
    Wu, Hongliang
    Sun, Yanan
    Ji, Zhongyin
    You, Jinmao
    Suo, Yourui
    Ding, Chenxu
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2018, 41 (02) : 49 - 57