Characterization of statistical prior image constrained compressed sensing. I. Applications to time-resolved contrast-enhanced CT

被引:28
|
作者
Lauzier, Pascal Theriault [1 ]
Chen, Guang-Hong [1 ,2 ]
机构
[1] Univ Wisconsin, Dept Med Phys, Madison, WI 53705 USA
[2] Univ Wisconsin, Dept Radiol, Madison, WI 53705 USA
基金
加拿大自然科学与工程研究理事会; 美国国家卫生研究院;
关键词
compressed sensing; computed tomography; iterative reconstruction algorithms; maximum a posteriori estimation; dynamic imaging; BEAM COMPUTED-TOMOGRAPHY; NOISE-POWER SPECTRUM; VISUAL SIGNAL-DETECTION; DYNAMIC PERFUSION CT; TEMPORAL RESOLUTION; RECONSTRUCTION ALGORITHMS; ORDERED SUBSETS; ITERATIVE RECONSTRUCTION; TRANSMISSION TOMOGRAPHY; MYOCARDIAL-PERFUSION;
D O I
10.1118/1.4748323
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Prior image constrained compressed sensing (PICCS) is an image reconstruction framework that takes advantage of a prior image to improve the image quality of CT reconstructions. An interesting question that remains to be investigated is whether or not the introduction of a statistical model of the photon detection in the PICCS reconstruction framework can improve the performance of the algorithm when dealing with high noise projection datasets. The goal of the research presented in this paper is to characterize the noise properties of images reconstructed using PICCS with and without statistical modeling. This paper investigates these properties in the clinical context of time-resolved contrast-enhanced CT. Methods: Both numerical phantom studies and an Institutional Review Board approved human subject study were used in this research. The conventional filtered backprojection (FBP), and PICCS with and without the statistical model were applied to each dataset. The prior image used in PICCS was generated by averaging over FBP reconstructions from different time frames of the time-resolved CT exam, thus reducing the noise level. Numerical studies were used to evaluate if the noise characteristics are altered for varying levels of noise, as well as for different object shapes. The dataset acquired in vivo was used to verify that the conclusions reached from numerical studies translate adequately to a clinical case. The results were analyzed using a variety of qualitative and quantitative metrics such as the universal image quality index, spatial maps of the noise standard deviations, the noise uniformity, the noise power spectrum, and the model-observer detectability. Results: The noise characteristics of PICCS were shown to depend on the noise level contained in the data, the level of eccentricity of the object, and whether or not the statistical model was applied. Most differences in the characteristics were observed in the regime of low incident x-ray fluence. No substantial difference was observed between PICCS with and without statistics in the high fluence domain. Objects with a semi-major axis ratio below 0.85 were more accurately reconstructed with lower noise using the statistical implementation. Above that range, for mostly circular objects, the PICCS implementation without the statistical model yielded more accurate images and a lower noise level. At all levels of eccentricity, the noise spatial distribution was more uniform and the model-observer detectability was greater for PICCS with the statistical model. The human subject study was consistent with the results obtained using numerical simulations. Conclusions: For mildly eccentric objects in the low noise regime, PICCS without the noise model yielded equal or better noise level and image quality than the statistical formulation. However, in a vast majority of cases, images reconstructed using statistical PICCS have a noise power spectrum that facilitated the detection of model lesions. The inclusion of a statistical model in the PICCS framework does not always result in improved noise characteristics. (C) 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4748323]
引用
收藏
页码:5930 / 5948
页数:19
相关论文
共 20 条
  • [11] Accelerated Time-Resolved Contrast-Enhanced Magnetic Resonance Angiography of Dural Arteriovenous Fistulas Using Highly Constrained Reconstruction of Sparse Cerebrovascular Data Sets
    Clark, Zachary
    Johnson, Kevin M.
    Wu, Yijing
    Edjlali, Myriam
    Mistretta, Charles
    Wieben, Oliver
    Turski, Patrick
    INVESTIGATIVE RADIOLOGY, 2016, 51 (06) : 365 - 371
  • [12] BAYESIAN COMPRESSED SENSING ALGORITHM FOR CONTRAST-ENHANCED LOW-DOSE CT IMAGE WITH IODINE BASED ON CARBON NANOTUBE X-RAY TUBE
    Liu, Xiaopei
    Teng, Jianfu
    Fei, Teng
    Sun, Yunshan
    ACTA MEDICA MEDITERRANEA, 2022, 38 (02): : 1257 - 1262
  • [13] Comparison of time-resolved CT-angiography, contrast-enhanced ultrasound and digital subtraction angiography in a patient with a small type II endoleak after endovascular aneurysm repair
    Sommer, Wieland H.
    Hoffmann, Ralf. T.
    Becker, Christoph R.
    Reiser, Maximilian F.
    Clevert, Dirk A.
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2010, 45 (01) : 19 - 25
  • [14] Evaluation of image quality of pituitary dynamic contrast-enhanced MRI using time-resolved angiography with interleaved stochastic trajectories (TWIST) and iterative reconstruction TWIST (IT-TWIST)
    Yokota, Yusuke
    Fushimi, Yasutaka
    Okada, Tomohisa
    Fujimoto, Koji
    Oshima, Sonoko
    Nakajima, Satoshi
    Fujii, Toshihito
    Tanji, Masahiro
    Inagaki, Nobuya
    Miyamoto, Susumu
    Togashi, Kaori
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2020, 51 (05) : 1497 - 1506
  • [15] Contrast-enhanced time-resolved 4D MRA of congenital heart and vessel anomalies: image quality and diagnostic value compared with 3D MRA
    Vogt, Florian M.
    Theysohn, Jens M.
    Michna, Dariusz
    Hunold, Peter
    Neudorf, Ulrich
    Kinner, Sonja
    Barkhausen, Joerg
    Quick, Harald H.
    EUROPEAN RADIOLOGY, 2013, 23 (09) : 2392 - 2404
  • [16] Contrast-enhanced time-resolved 4D MRA of congenital heart and vessel anomalies: image quality and diagnostic value compared with 3D MRA
    Florian M. Vogt
    Jens M. Theysohn
    Dariusz Michna
    Peter Hunold
    Ulrich Neudorf
    Sonja Kinner
    Jörg Barkhausen
    Harald H. Quick
    European Radiology, 2013, 23 : 2392 - 2404
  • [17] 3D time-resolved contrast-enhanced cerebrovascular MR angiography with subsecond frame update times using radial k-space trajectories and highly constrained projection reconstruction
    Wu, Y.
    Kim, N.
    Korosec, F. R.
    Turk, A.
    Rowley, H. A.
    Wieben, O.
    Mistretta, C. A.
    Turski, P. A.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2007, 28 (10) : 2001 - 2004
  • [18] New real-time image fusion technique for characterization of tumor vascularisation and tumor perfusion of liver tumors with contrast-enhanced ultrasound, spiral CT or MRI: First results
    Jung, E. M.
    Schreyer, A. G.
    Schacherer, D.
    Menzel, C.
    Farkas, S.
    Loss, M.
    Feuerbach, S.
    Zorger, N.
    Fellner, C.
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2009, 43 (1-2) : 57 - 69
  • [19] Prospective, single UK centre, comparative study of the predictive values of contrast-enhanced ultrasound compared to time-resolved CT angiography in the detection and characterisation of endoleaks in high risk patients undergoing endovascular aneurysm repair surveillance: a protocol
    Roy, Iain Nicholas
    Chan, Tze Yuan
    Czanner, Gabriela
    Wallace, Steve
    Vallabhaneni, Srinivasa Rao
    BMJ OPEN, 2018, 8 (04):