Seismic Behavior of Flange-Web Welded Plate Connections in Tubular and Concrete-Filled Columns Using Finite Element Analysis

被引:0
|
作者
Moncayo-Matute, Freddy Patricio [1 ]
Chicaiza-Machuca, Diego Fernando [1 ]
Velez-Sisalima, Israel Santiago [1 ]
Torres-Jara, Paul Bolivar [1 ]
Vazquez-Silva, Efren [1 ]
机构
[1] Univ Politecn Salesiana, Grp Invest Nuevos Mat & Proc Transformac GIMAT, Ingn Mecan, Sede Cuenca, Cuenca 010105, Ecuador
来源
APPLIED SCIENCES-BASEL | 2024年 / 14卷 / 15期
关键词
beam-to-column connections; steel structures; cyclic loading; plastic hinge; finite element method; hysteretic curve; PERFORMANCE; BEAMS;
D O I
10.3390/app14156494
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The present study analyzes the behavior of connections with flange-web welded plates using the finite element method in tubular columns filled with concrete, and beam, type I. An analytical study of the structural dynamic behavior of a Special Moment Frame (SMF) was carried out, in 5 levels, with HEB structural profiles, for IPE-type columns and beams, according to the requirements established by the AISC-360-16, ANSI-341 standards, and the Ecuadorian standard NEC-2015. The design process of the special frame structure was validated with the help of specialized software. Subsequently, the structural profiles were replaced following the actual construction situation in Ecuador. 3D models of the structural system and the elements of metallic connections were obtained for evaluation through the analysis of finite elements. These models were subjected to virtual tests according to the AISC 341-16 protocols and FEMA 350 standards. The evaluation of the connections showed that they did not meet the flexural strength criterion at 0.04 rad, but they exceeded 80% of the plastic moment at 0.02 rad. Thus, flange-web welded plate connections can be valid for intermediate moment frames (IMF) in areas with moderate seismicity. In addition, it was observed that the columns filled with concrete optimize the structural elements in terms of dimensions; but do not contribute significantly to soldered connections due to the later development of plastic ball joints.
引用
收藏
页数:21
相关论文
共 50 条
  • [31] Impact Statement on "Advanced Materials for Concrete-Filled Tubular Columns and Connections"
    Espinos, Ana
    Romero, Manuel L.
    Hospitaler, Antonio
    Pascual, Ana M.
    Albero, Vicente
    STRUCTURES, 2016, 8 : 154 - 154
  • [32] Flexural behavior of prestressed concrete-filled steel tubular flange beams
    Ghaemdoust, Mohammad Reza
    Yang, Jian
    Wang, Feiliang
    Li, Siping
    Jamhiri, Babak
    STRUCTURES, 2022, 43 : 1643 - 1667
  • [33] SEISMIC BEHAVIOR OF BIAXIAL HOLLOW REINFORCED CONCRETE SLAB TO CONCRETE-FILLED STEEL TUBULAR COLUMN CONNECTIONS
    Gong, Chao
    Hou, Zhao-Xin
    Cheng, Guo-Zhong
    Chen, Y. Frank
    Liang, Wei-Qiao
    ADVANCED STEEL CONSTRUCTION, 2020, 16 (03): : 223 - 232
  • [34] NONLINEAR FINITE ELEMENT ANALYSIS OF SEISMIC BEHAVIOR OF STEEL FIBER REINFORCED HIGH STRENGTH CONCRETE-FILLED STEEL TUBE COLUMNS
    Chen, Juan
    PROCEEDINGS OF INTERNATIONAL CONFERENCE ON EARTHQUAKE ENGINEERING - THE FIRST ANNIVERSARY OF WENCHUAN EARTHQUAKE, 2009, : 400 - 404
  • [35] Elastoplastic behavior of through-diaphragm connections to concrete-filled rectangular steel tubular columns
    Qin, Ying
    Chen, Zhihua
    Wang, Xiaodun
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2014, 93 : 88 - 96
  • [36] Seismic performance of concrete-filled steel tubular column connections using blind bolts
    Gan, Dan
    Zhang, Yaojun
    Zhou, Xuhong
    Ba, Ziyu
    Li, Dongxu
    Hou, Zhaoxin
    Uy, Brian
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2023, 207
  • [37] Nonlinear finite element analysis of anchored blind-bolted joints to concrete-filled steel tubular columns
    Wang Y.
    Wang Z.
    Pan J.
    Wang P.
    International Journal of Performability Engineering, 2019, 15 (02): : 676 - 687
  • [38] Behavior of eccentrically loaded concrete-filled steel tubular columns
    Fujimoto, T
    Mukai, A
    Nishiyama, I
    Sakino, K
    JOURNAL OF STRUCTURAL ENGINEERING, 2004, 130 (02) : 203 - 212
  • [39] Behavior of fiber reinforced concrete-filled tubular columns in compression
    G. Campione
    L. La Mendola
    L. Sanpaolesi
    N. Scibilia
    G. Zingone
    Materials and Structures, 2002, 35 : 332 - 337
  • [40] Nonlinear analysis and behavior of concrete-filled steel tubular beam-columns
    Liang, Q. Q.
    Hadi, M. N. S.
    INNOVATIONS IN STRUCTURAL ENGINEERING AND CONSTRUCTION, VOLS 1 AND 2, 2008, : 777 - +