Pseudo dual-energy CT-derived iodine mapping using single-energy CT data based on a convolution neural network

被引:0
|
作者
Yuasa, Yuki [1 ]
Shiinoki, Takehiro [1 ]
Fujimoto, Koya [1 ]
Tanaka, Hidekazu [1 ]
机构
[1] Yamaguchi Univ, Grad Sch Med, Dept Radiat Oncol, Ube, Yamaguchi, Japan
来源
BJR OPEN | 2023年 / 5卷 / 01期
基金
日本学术振兴会;
关键词
COMPUTED-TOMOGRAPHY; IMAGE QUALITY; CONTRAST;
D O I
10.1259/bjro.20220059
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The objectives of this study are: (1) to develop a convolutional neural network model that yields pseudo high-energy CT (CTpseudo_high) from simple image processed low-energy CT (CTlow) images, and (2) to create a pseudo iodine map (IMpseudo) and pseudo virtual non-contrast (VNCpseudo) images for thoracic and abdominal regions.Methods: Eighty patients who underwent dual-energy CT (DECT) examinations were enrolled. The data obtained from 55, 5, and 20 patients were used for training, validation, and testing, respectively. The ResUnet model was used for image generation model and was trained using CTlow and high-energy CT (CThigh) images. The proposed model performance was evaluated by calculating the CT values, image noise, mean absolute errors (MAEs), and histogram intersections (HIs).Results: The mean difference in the CT values between CTpseudo_high and CThigh images were less than 6 Hounsfield unit (HU) for all evaluating patients. The image noise of CTpseudo_high was significantly lower than that of CThigh. The mean MAEs was less than 15 HU, and HIs were almost 1.000 for all the patients. The evaluation metrics of IM and VNC exhibited the same tendency as that of the comparison between CTpseudo_high and CThigh images.Conclusions: Our results indicated that the proposed model enables to obtain the DECT images and material-specific images from only single-energy CT images.Advances in knowledges: We constructed the CNN-based model which can generate pseudo DECT image and DECT-derived material-specific image using only simple image-processed CTlow images for the thoracic and abdominal regions.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] CT Detection of Myocardial Blood Volume Deficits: Dual-Energy CT Compared With Single-Energy CT Spectra
    Arnoldi, Elisabeth
    Ruzsics, Balazs
    Lee, Yeong Shyan
    Gebregziabher, Mulugeta
    Nikolaou, Konstantin
    Reiser, Maximilian F.
    Costello, Philip
    Schoepf, U. Joseph
    CIRCULATION, 2009, 120 (18) : S375 - S375
  • [22] Prospective comparison of dual-energy CT aortography using 70% reduced iodine dose versus single-energy CT aortography using standard iodine dose in the same patient
    Shuman, William P.
    O'Malley, Ryan B.
    Busey, Janet M.
    Ramos, Mario M.
    Koprowicz, Kent M.
    ABDOMINAL RADIOLOGY, 2017, 42 (03) : 759 - 765
  • [23] Prospective comparison of dual-energy CT aortography using 70% reduced iodine dose versus single-energy CT aortography using standard iodine dose in the same patient
    William P. Shuman
    Ryan B. O’Malley
    Janet M. Busey
    Mario M. Ramos
    Kent M. Koprowicz
    Abdominal Radiology, 2017, 42 : 759 - 765
  • [24] Comparison of metal artifact reduction using single-energy CT and dual-energy CT with various metallic implants in cadavers
    Barreto, Izabella
    Pepin, Eric
    Davis, Ivan
    Dean, Cooper
    Massini, Tara
    Rees, John
    Olguin, Catherine
    Quails, Nathan
    Correa, Nathalie
    Rill, Lynn
    Arreola, Manuel
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 133
  • [25] Direct Dose Measurements Comparing Single-Energy and Dual-Energy Head CT Scan
    Correa, N.
    Glassell, M.
    Schaeffer, C.
    Barreto, I.
    Arreola, M.
    MEDICAL PHYSICS, 2022, 49 (06) : E434 - E434
  • [26] Clinical significance of dual-energy CT-derived iodine quantification in the diagnosis of metastatic LN in colorectal cancer
    Kato, T.
    Uehara, K.
    Ishigaki, S.
    Nihashi, T.
    Arimoto, A.
    Nakamura, H.
    Kamiya, T.
    Oshiro, T.
    Ebata, T.
    Nagino, M.
    EJSO, 2015, 41 (11): : 1464 - 1470
  • [27] Real-time diagnosis of intracerebral hemorrhage by generating dual-energy CT from single-energy CT
    Jiang, Caiwen
    Wang, Tianyu
    Pan, Yongsheng
    Ding, Zhongxiang
    Shen, Dinggang
    MEDICAL IMAGE ANALYSIS, 2024, 95
  • [28] The Effect of Beam Overlapping in Dual-Energy Volume CT Scans and Single-Energy Helical Scans
    Correa, N.
    Barreto, I.
    Arreola, M.
    MEDICAL PHYSICS, 2022, 49 (06) : E648 - E648
  • [29] Accuracy of liver metastasis detection and characterization: Dual-energy CT versus single-energy CT with deep learning reconstruction
    Jensen, Corey T.
    Wong, Vincenzo K.
    Wagner-Bartak, Nicolaus A.
    Liu, Xinming
    Sobha, Renjith Padmanabhan Nair
    Sun, Jia
    Likhari, Gauruv S.
    Gupta, Shiva
    EUROPEAN JOURNAL OF RADIOLOGY, 2023, 168
  • [30] Virtual non-contrast dual-energy CT compared to single-energy CT of the urinary tract: a prospective study
    Lundin, Margareta
    Liden, Mats
    Magnuson, Anders
    Mohammed, Ahmed Abdulilah
    Geijer, Hakan
    Andersson, Torbjorn
    Persson, Anders
    ACTA RADIOLOGICA, 2012, 53 (06) : 689 - 694