Trocar-assisted extraocular technique for intrascleral intraocular lens fixation using a 90°-curved forceps: a modified extraocular forceps-guided technique

被引:0
|
作者
Kisanuki, Yuki [1 ]
Asano, Yasuhiko [1 ]
Tomoyori, Eiji [1 ]
Onda, Hidetoshi [1 ]
机构
[1] Showa Univ, Sch Med, Dept Ophthalmol, 1-5-8 Hatanodai,Shinagawa Ku, Tokyo 1428555, Japan
关键词
Extraocular technique; Intrascleral intraocular lens fixation; Pars plana vitrectomy; Secondary intraocular lens implantation; Trocar-assisted technique; IMPLANTATION; NEEDLES; EYES;
D O I
10.1007/s10384-024-01099-7
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To investigate the surgical outcomes of intrascleral intraocular lens (IOL) fixation using a modified extraocular forceps-guided technique. Study design Retrospective case series. Methods Overall, 81 eyes of 78 patients who underwent intrascleral IOL fixation using the modified extraocular forceps-guided technique were included. The procedure entailed creating 2 scleral half-layer T-shaped incisions perpendicular to the main incision and forming a scleral tunnel. A 25-gauge trocar was inserted at the lower end of the T-shaped incision to perform vitrectomy. A 27-gauge needle was inserted from the left-hand port, and the leading haptic was inserted into the needle lumen. After removal of the right-hand trocar, a 90 degrees-curved intrascleral fixation forceps was inserted into the eye, exposing the tip at the main incision, thus allowing the tip of the extraocular trailing haptic to be gripped and both haptics to be pulled out. The left-hand trocar was removed, and the haptics were buried in the scleral tunnel. The surgical outcomes of this technique were retrospectively evaluated on the basis of the medical records. Results The induction of haptics was successful in all cases. The preoperative best-corrected visual acuity improved from 0.35 +/- 0.68 to 0.12 +/- 0.36 logMAR postoperatively (P<0.01). The refractive error was -0.27 +/- 0.87 D; IOL decentration, 0.39 +/- 0.18 mm; IOL tilt, 5.97 +/- 2.65 degrees; IOL astigmatism, 0.35 +/- 0.36 D; and corneal endothelial cell loss, 10.3 +/- 12.7%. There were no serious complications related to the surgical technique. Conclusion The modified extraocular forceps-guided technique allows for safe and straightforward induction of the trailing haptics and enables the performance of intrascleral IOL fixation with minimal scleral incisions.
引用
收藏
页码:538 / 547
页数:10
相关论文
共 31 条
  • [21] Modified method of haptic externalization of posterior chamber intraocular lens in fibrin glue-assisted intrascleral fixation: No-assistant technique
    Narang, Priya
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (01): : 4 - 7
  • [22] Clinical Outcomes of Endoscope-Assisted 30-Gauge Single-Needle Technique for Intrascleral Intraocular Lens Fixation
    Mitamura, Hayato
    Kaga, Tatsushi
    Kojima, Takashi
    Yoshida, Norihiko
    Sato, Hiroyuki
    Matsuda, Taisuke
    Yokoyama, Sho
    Mori, Toshio
    Ichikawa, Kazuo
    OPHTHALMIC RESEARCH, 2021, 64 (02) : 253 - 260
  • [24] Surgical Technique for Sutureless Intrascleral Fixation of a 3-Piece Intraocular Lens Using a 30-Gauge Needle
    Bonnell, Alyssa C.
    Mantopoulos, Dimosthenis
    Wheatley, H. Matthew
    Prenner, Jonathan L.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2019, 39 : 13 - 15
  • [25] Secondary intraocular lens implantation using the flanged intrascleral fixation technique in pediatric aphakia: case series and review of literature
    Sternfeld, Amir
    Basith, Syeda Sumara Taranum
    Kurup, Sudhi P.
    Basti, Surendra
    JOURNAL OF AAPOS, 2020, 24 (05): : 286.e1 - 286.e6
  • [26] Novel Technique for 27-Gauge Forceps-Assisted Transscleral Refixation of the Dislocated CZ70BD Intraocular Lens
    Yip, Lai Ting
    Fong, Angie
    Tsang, Chi Wai
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2023, 43 (10): : 1807 - 1810
  • [27] Sutureless intrascleral fixation of intraocular lens through self-sealing sclerotomy wounds using haptic externalization and reinternalization technique
    van Rensburg, Ernst Janse
    Ryu, Christina L.
    Vila, Natalia
    Chen, John C.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (10): : 1367 - 1371
  • [28] Intraocular lens roll-up technique: Foldable IOL implantation using forceps through incisions smaller than 3.2 mm
    Fukami, Shin
    Yamamoto, Narumichi
    Murakami, Kimio
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (12): : 2023 - 2027
  • [29] A modified intrascleral intraocular lens fixation technique with fewer anterior segment manipulations: 27-gauge needle-guided procedure with built-in 8–0 absorbable sutures
    Yuan Yang
    Teng-teng Yao
    Ya-li Zhou
    Yi-xiao Wang
    Zhao-yang Wang
    BMC Ophthalmology, 19
  • [30] A modified intrascleral intraocular lens fixation technique with fewer anterior segment manipulations: 27-gauge needle-guided procedure with built-in 8-0 absorbable sutures
    Yang, Yuan
    Yao, Teng-teng
    Zhou, Ya-li
    Wang, Yi-xiao
    Wang, Zhao-yang
    BMC OPHTHALMOLOGY, 2019, 19 (01)