High-Resolution Ocular Surface Imaging: Real-Time Visualization of Tear Film Dysfunction

被引:0
|
作者
Coroneo, Minas T. [1 ,2 ]
Kokkinakis, Jim [3 ,4 ]
Lee, Brendon W. H. [1 ,5 ]
Chen, Helen [2 ]
Tat, Lien [2 ]
机构
[1] UNSW Med & Hlth, Prince Wales Hosp, Sch Clin Med, Dept Ophthalmol, Sydney, NSW 2031, Australia
[2] Ophthalm Surg, Randwick, NSW, Australia
[3] Western Sydney Univ, Univ New South Wales, Sch Optometry, Sydney, NSW, Australia
[4] Western Sydney Univ, Univ New South Wales, Sch Sci, Sydney, NSW, Australia
[5] Univ Sydney, Sydney Med Sch, Sydney, NSW, Australia
关键词
dry eye; diagnosis; tear film; keratitis sicca; DRY EYE DISEASE; SYMPTOMS; DIAGNOSIS; SIGNS; TEMPERATURE; PATTERNS;
D O I
10.1097/ICO.0000000000003579
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose:Recent advancements in infrared sensing technology have made it possible to visualize tear film dynamics in real time, enabling evaluation of tear film quality during blinking. A retrospective clinical evaluation was conducted to explore this by grading videos of the tear film and comparing grading data with dry eye diagnostic results using the OCULUS keratograph (K5M).Methods:Videos were used to grade patients' tear film perturbations as compared with healthy control subjects. The grading was then correlated with the ocular surface disease index (OSDI) scores, tear film breakup time (TFBUT), tear meniscus height (TMH), corneal staining, redness, and meibography data.Results:Infrared imaging of the ocular surface revealed instantaneous and recurring dynamic characteristics of the tear film, allowing for the differentiation between normal and abnormal tear films. Abnormal features included a complete absence of a spreading tear film, hindered spreading of the tear film after blinking, areas of tear film instability, or a combination of the latter 2. Some of these features show a resemblance to the tear film appearance after fluorescein staining. The grading of these features correlated with TFBUT and, to a lesser extent, with TMH but did not show significant correlation with any other diagnostic data from the K5M. Furthermore, the speed of tear film spreading after blinking showed a positive correlation with TMH.Conclusions:Direct visualization of the tear film across the entire palpebral aperture using infrared sensing offers a noninvasive, reproducible, and rapid method for assessing the health and quality of the tear film.
引用
收藏
页码:1072 / 1079
页数:8
相关论文
共 50 条
  • [41] HIGH-RESOLUTION REAL-TIME ULTRASOUND OF THE CAROTID BIFURCATION
    COOPERBERG, PL
    ROBERTSON, WD
    FRY, P
    SWEENEY, V
    JOURNAL OF CLINICAL ULTRASOUND, 1979, 7 (01) : 13 - 17
  • [42] Real-Time Compression System for High-Resolution Image
    Deng, Chen-Wei
    Zhao, Bao-Jun
    ICSP: 2008 9TH INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING, VOLS 1-5, PROCEEDINGS, 2008, : 466 - 469
  • [43] HIGH-RESOLUTION REAL-TIME ULTRASONOGRAPHY OF NEONATAL KIDNEYS
    SCHEIBLE, W
    LEOPOLD, GR
    JOURNAL OF ULTRASOUND IN MEDICINE, 1982, 1 (04) : 133 - 138
  • [44] High-resolution real-time three-dimensional acoustic imaging system with a reflector
    Hirofumi Taki
    Toru Sato
    Journal of Medical Ultrasonics, 2007, 34 : 133 - 144
  • [45] High-resolution real-time three-dimensional acoustic imaging system with a reflector
    Taki, Hirofumi
    Sato, Toru
    JOURNAL OF MEDICAL ULTRASONICS, 2007, 34 (03) : 133 - 144
  • [46] THYROID IMAGING - COMPARISON OF HIGH-RESOLUTION REAL-TIME ULTRASOUND AND COMPUTED-TOMOGRAPHY
    RADECKI, PD
    ARGER, PH
    ARENSON, RL
    JENNINGS, AS
    COLEMAN, BG
    MINTZ, MC
    KRESSEL, HY
    RADIOLOGY, 1984, 153 (01) : 145 - 147
  • [47] Studying Oral Tissue via Real-Time High-Resolution Terahertz Spectroscopic Imaging
    Yang, Shengxin
    Ding, Liang
    Wang, Shuai
    Du, Chen
    Feng, Longcheng
    Qiu, Hongsong
    Zhang, Caihong
    Wu, Jingbo
    Fan, Kebin
    Jin, Biaobing
    Chen, Jian
    Wu, Peiheng
    PHYSICAL REVIEW APPLIED, 2023, 19 (03)
  • [48] Real-time interactive imaging enhanced high-resolution magnetic resonance coronary angiogram
    Yang, PC
    Meyer, CH
    Rivas, PA
    Macovski, A
    Pauly, JM
    Nishimura, DG
    Hu, BS
    CIRCULATION, 1999, 100 (18) : 522 - 522
  • [49] Compact broadband high-resolution real-time four-dimensional imaging spectrometer
    Yang, Qinghua
    APPLIED OPTICS, 2024, 63 (23) : 6188 - 6200
  • [50] High-resolution imaging with a real-time synthetic aperture ultrasound system: A phantom study
    Huang, Lianjie
    Labyed, Yassin
    Simonetti, Francesco
    Williamson, Michael
    Rosenberg, Robert
    Heintz, Philip
    Sandoval, Daniel
    MEDICAL IMAGING 2011: ULTRASONIC IMAGING, TOMOGRAPHY, AND THERAPY, 2011, 7968