Modelling real non-linear loads for a Controller Hardware-in-the-Loop configuration to evaluate a Shunt Active Power Filter

被引:0
|
作者
Guerrero-Rodriguez, N. F. [1 ]
Nunez-Ramirez, Vrindarani [1 ]
Batista-Jorge, Rafael Omar [1 ]
Mercado-Ravelo, Robert [1 ]
Ramirez-Rivera, F. A. [1 ]
Ferreira, Julio A. [1 ]
Reyes-Archundia, Enrique [2 ]
机构
[1] Pontificia Univ Catolica Madre & Maestra PUCMM, Engn Sci, Ave Abraham Lincoln Esq Romulo Betancourt, Santo Domingo 2748, Dominican Rep
[2] Tecnol Nacl Mexico, Inst Tecnol Morelia, Ave Tecnol 1500, Morelia 58120, Michoacan, Mexico
关键词
Shunt Active Power Filters (SAPF); Non-linear load; Controller Hardware-In-the-Loop (CHIL) Simu-lation; Power quality; Harmonic mitigation; IEEE-519; standard;
D O I
10.1016/j.egyr.2024.07.056
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This work shows the design and validation of a Shunt Active Power Filters (SAPF) using Controller Hardware-Inthe-Loop (CHIL) Simulations by using a OP5707XG Real-Time Simulator module provided by OPAL-RT, an external OP8666 controller, a host PC and an oscilloscope for visualization. A novel methodology for the modelling of real non-linear electrical loads by making use of MATLAB/SIMULINK is presented. This allows, in conditions like real physical systems, an evaluation of the behavior of active filters before their prototyping, allowing improvements to be made in their design. For the compensation strategy, the calculation of a compensation current from the estimation of the ideal current is used. This strategy is implemented in a microcontroller system for validation with a CHIL configuration simulation. The results have demonstrated significant progress in harmonic mitigation, with the effectiveness of the SAPF in reducing the current Total Harmonic Distortion (THD) across various load types firmly established. As demonstrated in the test cases, the SAPFs significantly reduced THD from significant double-digit percentages to values well below 3 %. This confirms their significant impact on maintaining the integrity and quality of the power system.
引用
收藏
页码:1947 / 1976
页数:30
相关论文
共 50 条
  • [1] Incorporating Hardware-In-the-Loop Simulation and ADALINE for Shunt Active Power Filter Design
    Hong, R. C.
    Chang, G. W.
    Chao, C. Y.
    Chu, Y. B.
    Chen, C. I.
    ICIEA 2010: PROCEEDINGS OF THE 5TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, VOL 1, 2010, : 527 - +
  • [2] A real-time power Hardware-in-the-Loop implementation of an active filter
    Javadi, Alireza
    Olivier, Guy
    Sirois, Frederic
    PRZEGLAD ELEKTROTECHNICZNY, 2010, 86 (11A): : 7 - 12
  • [3] Simulation of Single Phase Shunt Active Power Filter for Domestic Non-linear Loads
    Joshi, Payal K.
    Bohra, Shabbir S.
    PROCEEDINGS OF THE 2013 IEEE 8TH CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA), 2013, : 43 - 48
  • [4] A novel controller design methodology for uncertain non-linear hardware-in-the-loop simulators
    MacDiarmid, Monte
    Daniel, Ronald
    Bacic, Marko
    PROCEEDINGS OF THE 46TH IEEE CONFERENCE ON DECISION AND CONTROL, VOLS 1-14, 2007, : 3995 - 4000
  • [5] Research on Hardware-in-the-loop Simulation of Active Power Filter
    Yang Xiao-pin
    IEEE PEDG 2010: THE 2ND INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS FOR DISTRIBUTED GENERATION SYSTEMS, 2010, : 171 - 175
  • [6] Comparative Study of Different Control Algorithms of Shunt Active Power Filter for Non-Linear Loads
    Shabib, Gaber
    Hussein, Mahmoud M.
    Hasseeb, Mahmoud Mohammed
    2017 NINETEENTH INTERNATIONAL MIDDLE-EAST POWER SYSTEMS CONFERENCE (MEPCON), 2017, : 1037 - 1043
  • [7] Modelling of Output Admittance Coupling Between Shunt Active Power Filters and Non-linear Loads
    Lei, Jintao
    Qin, Zian
    Li, Wuhua
    Bauer, Pavol
    He, Xiangning
    2019 4TH IEEE WORKSHOP ON THE ELECTRONIC GRID (EGRID), 2019, : 143 - 147
  • [8] A non-linear optimal predictive control of a shunt active power filter
    Mendalek, N
    Fnaiech, F
    Al-Haddad, K
    Dessaint, LA
    CONFERENCE RECORD OF THE 2002 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-4, 2002, : 70 - 77
  • [9] Mitigation Of Harmonics Current Using Different Control Algorithms Of Shunt Active Power Filter For Non-Linear Loads
    Kamel, Khechiba
    Laid, Zellouma
    Abdallah, Kouzou
    PROCEEDINGS OF THE 2018 INTERNATIONAL CONFERENCE ON APPLIED SMART SYSTEMS (ICASS), 2018,
  • [10] New Series Active Power Filter for Computers Loads and Small Non-Linear Loads
    Tarnini, Mohamed
    WCECS 2009: WORLD CONGRESS ON ENGINEERING AND COMPUTER SCIENCE, VOLS I AND II, 2009, : 545 - 549