A Systematic Review of Surgical Characteristics and Adverse Events of an Active, Transcutaneous Bone Conduction Device

被引:0
|
作者
Jukic, Alma [1 ]
Munhall, Christopher C. [2 ]
Stevens, Shawn M. [3 ]
机构
[1] Univ Arizona, Coll Med Phoenix, Phoenix, AZ USA
[2] Med Univ South Carolina, Dept Otolaryngol Head & Neck Surg, Charleston, SC USA
[3] Barrow Neurol Inst, Dept Otolaryngol & Skull Base Surg, 2910 N 3rd Ave, Phoenix, AZ 85013 USA
来源
关键词
active transcutaneous hearing device; bone conduction implant; hearing loss; conductive hearing loss; Osia; bone-anchored hearing aid; CLINICAL-PERFORMANCE; IMPLANT; OUTCOMES; BAHA;
D O I
10.1177/00034894241283269
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objective: A new, active transcutaneous bone conduction device (BCD) was FDA-approved in 2019 in the USA. This systematic review sought to evaluate early outcomes associated with Osia implantation. Methods: A systematic review was conducted according to Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) guidelines. Four databases were reviewed: PubMed, Scopus, Cochrane CENTRAL, and CINAHL. Studies were included if they described audiometric, surgical characteristics/complications, or adverse events associated with the Osia BCD. Exclusion criteria: non-English language studies, animal investigations, reviews/meta-analyses, case reports, database studies. Results: Eighteen studies with 336 patients were included. Mean age at implantation was 37.9 years. About 79.5% of patients had MHL/CHL and 19.5% had SSD/SHL. Mean operative time was 71.6 minutes. Mean PTA gain from unaided conditions was 35.4 dB. Mean functional gain at high frequency (6 kHz and above) from aided conditions was 16.1 dB. Mean improvement in speech recognition thresholds was 19.1 dB from unaided conditions. Adverse events (all types) were reported in 20.1% of cases. Across all studies, the postoperative infection rate was 5%. About 2% of patients reported magnet retention issues. About 1.65% of cases were complicated by hematomas. Conclusions: Under systematic literature review, the Osia BCD has been associated with low complication rates, relatively short operative times, and good audiometric and speech outcomes, notably high frequency gain >6 kHz. More advanced audiometric outcome reporting remains limited and audiometric data and patient reported outcome measures were reported heterogeneously.
引用
收藏
页码:956 / 966
页数:11
相关论文
共 50 条
  • [21] Safety and Efficacy of Implantation of the Bonebridge Active Transcutaneous Bone-Conduction Device Using Implant Lifts
    Brkic, Faris F.
    Riss, Dominik
    Arnoldner, Christoph
    Liepins, Rudolfs
    Gstoettner, Wolfgang
    Baumgartner, Wolf-Dieter
    Vyskocil, Erich
    JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2021, 32 (05) : 290 - 294
  • [22] Initial UK Experience With a Novel Magnetic Transcutaneous Bone Conduction Device
    Carr, Simon D.
    Moraleda, Javier
    Procter, Vicky
    Wright, Kay
    Ray, Jaydip
    OTOLOGY & NEUROTOLOGY, 2015, 36 (08) : 1399 - 1402
  • [23] Intermediate outcomes of a transcutaneous bone conduction hearing device in a paediatric population
    Dimitriadis, Panagiotis A.
    Carrick, Suzanne
    Ray, Jaydip
    INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2017, 94 : 59 - 63
  • [24] Long-term audiological benefit with an active transcutaneous bone-conduction device: a retrospective cohort analysis
    Hundertpfund, Julia
    Meyer, Jens Eduard
    Ovari, Attila
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2022, 279 (07) : 3309 - 3326
  • [25] Audiological results and subjective benefit of an active transcutaneous bone-conduction device in patients with congenital aural atresia
    Veronika Volgger
    Inge Teresa Schießler
    Joachim Müller
    Florian Schrötzlmair
    Marlene Pollotzek
    John Martin Hempel
    European Archives of Oto-Rhino-Laryngology, 2022, 279 : 2345 - 2352
  • [26] Long-term audiological benefit with an active transcutaneous bone-conduction device: a retrospective cohort analysis
    Julia Hundertpfund
    Jens Eduard Meyer
    Attila Ovari
    European Archives of Oto-Rhino-Laryngology, 2022, 279 : 3309 - 3326
  • [27] Audiological results and subjective benefit of an active transcutaneous bone-conduction device in patients with congenital aural atresia
    Volgger, Veronika
    Schiessler, Inge Teresa
    Mueller, Joachim
    Schroetzlmair, Florian
    Pollotzek, Marlene
    Hempel, John Martin
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2021, 279 (5) : 2345 - 2352
  • [28] Surgical and functional outcomes of two types of transcutaneous bone conduction implants
    Scotta, G.
    Allam, A.
    Dimitriadis, P. A.
    Wright, K.
    Yardley, M.
    Ray, J.
    JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2020, 134 (12): : 1065 - 1068
  • [29] Occurrence and preventability of adverse drug events in surgical patients: a systematic review of literature
    Boeker, Eveline B.
    de Boer, Monica
    Kiewiet, Jordy J. S.
    Lie-A-Huen, Loraine
    Dijkgraaf, Marcel G. W.
    Boermeester, Marja A.
    BMC HEALTH SERVICES RESEARCH, 2013, 13
  • [30] Occurrence and preventability of adverse drug events in surgical patients: a systematic review of literature
    Eveline B Boeker
    Monica de Boer
    Jordy JS Kiewiet
    Loraine Lie-A-Huen
    Marcel GW Dijkgraaf
    Marja A Boermeester
    BMC Health Services Research, 13