Distal Metaphyseal Ulnar Shortening Osteotomy Fixation: A Biomechanical Analysis

被引:1
|
作者
Frey, Christopher S. [1 ]
Zhou, Joanne Y. [1 ]
Shah, Kalpit N. [2 ]
Chan, Calvin K. [1 ]
Joseph, Lauren [1 ]
Storaci, Hunter [1 ]
Segovia, Nicole [1 ]
Yao, Jeffrey [1 ]
机构
[1] Stanford Univ, Dept Orthopaed Surg, 450 Broadway St,MC 6342, Redwood City, CA 94603 USA
[2] Scripps Clin, San Diego, CA USA
来源
关键词
biomechanical; metaphyseal; ulnar impaction syndrome; ulnar shortening osteot- omy; USO; SCREW FIXATION; FRACTURES; COMPLICATIONS; COMPRESSION; RATES;
D O I
10.1016/j.jhsa.2022.11.007
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Ulnar shortening osteotomy can be used to treat ulnar impaction syndrome and other causes of ulnar wrist pain. Distal metaphyseal ulnar shortening osteotomy (DMUSO) is one technique that has been proposed to reduce the complications seen with a diaphyseal USO or a wafer resection. However, to our knowledge, the optimal fi xation construct for DMUSO has not been studied. We sought to characterize the biomechanical stiffness and rotational stability of different DMUSO constructs. Methods A DMUSO was performed on 40 human cadaveric ulnas using 4 different fi xation constructs (10 specimens per group): one 3.0 mm antegrade screw; two 2.2 mm antegrade screws; one 3.0 mm retrograde screw; and two 2.2 mm retrograde screws. Biaxial testing using axial load and cyclical axial torque was performed until failure, defined fi ned as 10 degrees degrees of rotation or 2 mm displacement. Specimens were assessed for stiffness at failure. Bone density was assessed using the second metacarpal cortical percentage. Results Bone density was similar between all 4 testing groups. Of the 4 groups, the 2 ante- grade screw group exhibited the highest rotational stiffness of 232 +/- 102 Nm/deg. In paired analysis, this was significantly fi cantly greater than 1 retrograde screw constructs. In multivariable analysis, 2-screw constructs were significantly fi cantly stiffer than 1 screw and antegrade constructs were significantly fi cantly stiffer than retrograde. Maximum failure torque did not differ with orientation, but 2 screws failed at significantly fi cantly higher torques. Conclusion Using 2 screws for DMUSO fixation constructs may provide higher stiffness and maximum failure torque, and antegrade screw constructs may provide more stiffness than retrograde constructs.
引用
收藏
页码:928e1 / 928e7
页数:7
相关论文
共 50 条
  • [31] Comparing radial lengthening osteotomy with ulnar shortening osteotomy to treat ulnar impaction syndrome after distal radius fracture malunion
    Hsuan-Hsiao Ma
    Yi-Chou Chen
    Hui-Kuang Huang
    Yi-Chao Huang
    Ming-Chau Chang
    Jung-Pan Wang
    Archives of Orthopaedic and Trauma Surgery, 2022, 142 : 525 - 531
  • [32] ULNAR SHORTENING AND RADIUS CORRECTIVE OSTEOTOMY IN DISTAL RADIUS MALUNION: A CASE REPORT
    Mao, Tian
    Xing, Shuguo
    Wang, Guheng
    ACTA MEDICA MEDITERRANEA, 2022, 38 (04): : 2381 - 2384
  • [33] Ulnar shortening osteotomy as a treatment of symptomatic ulnar impaction syndrome after malunited distal radius fractures
    Terzis, Athanasios
    Koehler, S.
    Sebald, J.
    Sauerbier, M.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2020, 140 (05) : 681 - 695
  • [34] Ulnar shortening osteotomy as a treatment of symptomatic ulnar impaction syndrome after malunited distal radius fractures
    Athanasios Terzis
    S. Koehler
    J. Sebald
    M. Sauerbier
    Archives of Orthopaedic and Trauma Surgery, 2020, 140 : 681 - 695
  • [35] Ulnar-shortening effect on distal radioulnar joint pressure: A biomechanical study
    Nishiwaki, Masao
    Nakamura, Toshiyasu
    Nagura, Takeo
    Toyama, Yoshiaki
    Ikegami, Hiroyasu
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2008, 33A (02): : 198 - 205
  • [36] Ulnar shortening osteotomy in posttraumatic ulnar impaction syndrome
    Fricker, R
    Pfeiffer, KM
    Troeger, H
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1996, 115 (3-4) : 158 - 161
  • [37] Ulnar shortening osteotomy in idiopathic ulnar impaction syndrome
    Baek, GH
    Chung, MS
    Lee, YH
    Gong, HS
    Lee, S
    Kim, HH
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (12): : 2649 - 2654
  • [38] A Novel Method of Osteosynthesis in Distal Forearm Transplantation Using an Ulnar-Shortening Osteotomy System for Simultaneous Both Bone Fixation
    Mendenhall, Shaun
    Schmucker, Ryan
    De la Garza, Mauricio
    Levin, L. Scott
    Neumeister, Michael
    TRANSPLANTATION, 2015, 99 : S15 - S15
  • [39] Ulnar shortening osteotomy for ulnar ideopathic impaction syndrome
    Moermans, Annelies
    Degreef, Ilse
    De Smet, Luc
    SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, 2007, 41 (06): : 310 - 314
  • [40] Biomechanical evaluation of intramedullary nail and bone plate for the fixation of distal metaphyseal fractures
    Nourisa, Jalil
    Rouhi, Gholamreza
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2016, 56 : 34 - 44