Novel PEI/Zein core-shell composite as mixed-mode stationary phase for high performance liquid chromatography

被引:2
|
作者
Shen, Qing [1 ,2 ,3 ]
Tang, Cong [1 ,2 ,3 ]
Xu, Xiaomeng [1 ,2 ,3 ]
Liu, Guangxiu [4 ]
Shao, Shijun [1 ,2 ]
Yao, Wenxiu [5 ]
Dong, Shuqing [1 ,2 ]
机构
[1] Chinese Acad Sci, Lanzhou Inst Chem Phys, Key Lab Chem Northwestern Plant Resources, Lanzhou 730000, Peoples R China
[2] Chinese Acad Sci, Lanzhou Inst Chem Phys, Key Lab Nat Med Gansu Prov, Lanzhou 730000, Peoples R China
[3] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[4] Chinese Acad Sci, Northwest Inst Ecoenvironm & Resources, Key Lab Extreme Environm Microbial Resources & Eng, Lanzhou 730000, Peoples R China
[5] Gansu Police Coll, Lanzhou 730046, Peoples R China
基金
中国国家自然科学基金;
关键词
Zein composites; Silicon-based core-shell structure; Liquid chromatography; Mixed-mode stationary phase; Hydrophobic/hydrophilic separation; ZEIN;
D O I
10.1016/j.chroma.2024.465159
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Based on the adhesion of polyethyleneimine (PEI), a novel PEI/zein co-modified core-shell stationary phase (PEI/ Zein@SiO2) was prepared by doping zein to form a composite modification layer. The stationary phase achieved effective separation of nucleosides, bases and antibiotics in hydrophilic interaction mode on account of the hydrophilic groups of composite coating. With the hydrophobicity of zein, the flavones could be separated in reversed-phase mode. In short, the separation and analysis of hydrophilic/hydrophobic compounds were accomplished excellently by the PEI/Zein@SiO2 column with mixed double mode. The prepared chromatographic stationary phase not only avoided the dissolution of zein, but also covered the strong adsorption of some analytes caused by silica hydroxyl groups on the surface of silica spheres. The morphological structure and specific surface area of the material were reflected by various characterization techniques. Hydrophilic/hydrophobic compounds were used as tested analytes to research separation performance and retention mechanisms of PEI/Zein@SiO2 column. The stability and reproducibility of the PEI/Zein@SiO2 stationary phase were satisfied. Therefore, the modification of zein could improve the separation selectivity of stationary phase effectively for complex samples, which had the potential to be one of the significant potential application materials in stationary phase packing.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Studies on the Characterization of Stationary Phase for Protein Retention on Mixed-mode Chromatography
    Jia Xiaodan
    Ke Congyu
    Sun Xuan
    Geng Xindu
    ACTA CHIMICA SINICA, 2012, 70 (15) : 1631 - 1636
  • [42] Preparation and post-modified of dicationic ionic liquid stationary phase and their application in mixed-mode liquid chromatography
    Zeng, Hanlin
    Peng, Jingdong
    Peng, Huanjun
    Yang, Hanqi
    Wang, Xiang
    Xu, Zhiqiang
    Chen, Wenhao
    MICROCHEMICAL JOURNAL, 2024, 202
  • [43] Dialdehyde cellulose-based mixed-mode stationary phases for diversified high-performance liquid chromatography separations
    Feng, Yumin
    Wu, Chaojun
    Hou, Yafei
    Zhang, Yanhao
    Yin, Dan
    Zhang, Wenfen
    Zhang, Shusheng
    JOURNAL OF CHROMATOGRAPHY A, 2024, 1736
  • [44] Core-Shell Diamond as a Support for Solid-Phase Extraction and High-Performance Liquid Chromatography
    Saini, Gaurav
    Jensen, David S.
    Wiest, Landon A.
    Vail, Michael A.
    Dadson, Andrew
    Lee, Milton L.
    Shutthanandan, V.
    Linford, Matthew R.
    ANALYTICAL CHEMISTRY, 2010, 82 (11) : 4448 - 4456
  • [45] A novel fullerene oxide functionalized silica composite as stationary phase for high performance liquid chromatography
    Liu, Houmei
    Guo, Yong
    Wang, Xusheng
    Liang, Xiaojing
    Liu, Xia
    Jiang, Shengxiang
    RSC ADVANCES, 2014, 4 (34): : 17541 - 17548
  • [46] Core-shell particles: Preparation, fundamentals and applications in high performance liquid chromatography
    Hayes, Richard
    Ahmed, Adham
    Edge, Tony
    Zhang, Haifei
    JOURNAL OF CHROMATOGRAPHY A, 2014, 1357 : 36 - 52
  • [47] An L-lysine derived organogelator-based stationary phase for mixed-mode liquid chromatography
    Guragain, Sudhina
    Mallik, Abul K.
    Takafuji, Makoto
    Ihara, Hirotaka
    ANALYTICAL METHODS, 2015, 7 (08) : 3320 - 3323
  • [48] NH2-carbon dot and hydrogel based stationary phase for mixed-mode liquid chromatography
    Zhang, Tong
    Liang, Xiaojing
    Chang, Lijing
    Lu, Xiaobing
    Li, Shuning
    Wang, Shuai
    Wang, Licheng
    MICROCHEMICAL JOURNAL, 2025, 210
  • [49] Understanding Mixed-Mode Retention Mechanisms in Liquid Chromatography with Hydrophobic Stationary Phases
    Cavazzini, Alberto
    Marchetti, Nicola
    Guzzinati, Roberta
    Pasti, Luisa
    Ciogli, Alessia
    Gasparrini, Francesco
    Lagana, Aldo
    ANALYTICAL CHEMISTRY, 2014, 86 (10) : 4919 - 4926
  • [50] Synthesis, characterization, and application of a novel multifunctional stationary phase for hydrophilic interaction/reversed phase mixed-mode chromatography
    Aral, Hayriye
    Celik, K. Serdar
    Altindag, Ramazan
    Aral, Tarik
    TALANTA, 2017, 174 : 703 - 714