Comparison of direct-drive Vernier wind generators for potential use at ≥10 MW power level

被引:0
|
作者
Kana Padinharu, Dileep Kumar [1 ]
Li, Guang-Jin [1 ]
Zhu, Zi-Qiang [1 ]
Wang, Peng [1 ]
Clark, Richard [2 ]
Azar, Ziad [2 ]
机构
[1] Univ Sheffield, Dept Elect & Elect Engn, Sheffield, England
[2] Siemens Gamesa Renewable Energy Ltd, Sheffield, England
基金
英国工程与自然科学研究理事会;
关键词
electric generators; electric power generation; machine theory; permanent magnet generators; permanent magnet machines; wind power;
D O I
10.1049/elp2.12477
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper investigates the benefits and challenges of the multi-MW direct-drive offshore wind Vernier generators. It is worth noting that the comparison of generator topologies presented in ref. [1] was for the same power level and therefore a reduced machine volume for the surface-mounted permanent magnet Vernier (SPM-V) generators. This would mainly impact the capital expenditure (CAPEX) cost between the different investigated machines. Whereas in this paper, the performance is compared for the same machine volume that allows the Vernier generators to produce a much higher energy yield than a conventional SPM generator. As the extra energy yield would be beneficial over the lifetime of the turbine, this will have a bigger impact than the CAPEX cost savings with a reduced machine volume. In addition, a novel Vernier machine with magnets on both the stator and rotor has been proposed to further improve the energy yield. In addition to the basic electromagnetic performance, the levelised cost of energy (LCOE) of the three generator topologies, that is, the conventional SPM, SPM-V and the proposed Vernier machines, has been compared. The direct-drive powertrain systems with SPM-V and the proposed Vernier generators can achieve LCOE of 12.3% and 24% lower than that of the conventional SPM generators, indicating their huge potential as an alternative to reduce the overall cost of energy. The authors investigate the benefits and challenges of the multi-MW direct-drive offshore wind Vernier generators. The performance is compared for the same machine volume that allows the Vernier generators to produce a much higher energy yield than a conventional SPM generator. As the extra energy yield would be beneficial over the lifetime of the turbine, this will have a bigger impact than the CAPEX cost savings with a reduced machine volume. image
引用
收藏
页码:1279 / 1292
页数:14
相关论文
共 50 条
  • [21] Direct-drive permanent magnet generators for high-power wind turbines: benefits and limiting factors
    Semken, R. Scott
    Polikarpova, M.
    Roytta, P.
    Alexandrova, J.
    Pyrhonen, J.
    Nerg, J.
    Mikkola, A.
    Backman, J.
    IET RENEWABLE POWER GENERATION, 2012, 6 (01) : 1 - 8
  • [22] 10-MW Direct-Drive PMSG-Based Wind Energy Conversion System Model
    Klinger Fisch, Leandro Benhur
    Heldwein, Marcelo Lobo
    2020 IEEE 21ST WORKSHOP ON CONTROL AND MODELING FOR POWER ELECTRONICS (COMPEL), 2020, : 587 - 594
  • [23] Design of a 10 MW Multi-Phase PM Synchronous Generator for Direct-Drive Wind Turbines
    Damiano, Alfonso
    Marongiu, Ignazio
    Monni, Andrea
    Porru, Mario
    39TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY (IECON 2013), 2013, : 5266 - 5270
  • [24] Analytical and Multiphysics Approach to the Optimal Design of a 10-MW DFIG for Direct-Drive Wind Turbines
    Colli, Vincenzo Delli
    Marignetti, Fabrizio
    Attaianese, Ciro
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2012, 59 (07) : 2791 - 2799
  • [25] 10 MW wind turbine direct-drive generator design with pitch or active speed stall control
    Polinder, H.
    Bang, D.
    van Rooij, R. P. J. O. M.
    McDonald, A. S.
    Mueller, M. A.
    IEEE IEMDC 2007: PROCEEDINGS OF THE INTERNATIONAL ELECTRIC MACHINES AND DRIVES CONFERENCE, VOLS 1 AND 2, 2007, : 1390 - +
  • [26] The Effect of the Electrical Steel Properties on the Temperature Distribution in Direct-Drive PM Synchronous Generators for 5 MW Wind Turbines
    Kowal, Damian
    Sergeant, Peter
    Dupre, Luc
    Vandenbossche, Lode
    IEEE TRANSACTIONS ON MAGNETICS, 2013, 49 (10) : 5371 - 5377
  • [27] Influence of electrical steel grade on the temperature distribution in direct-drive PM synchronous generators for 5 MW wind turbines
    Kowal, Damian
    Sergeant, Peter
    Dupre, Luc
    Vandenbossche, Lode
    2012 XXTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), 2012, : 1740 - 1744
  • [28] Switched reluctance (SR) generators for direct-drive wind energy converters (WEC)
    Mueller, M
    Jenkins, G
    Fulton, NN
    Turner, MJ
    WIND ENERGY 1999: WIND POWER COMES OF AGE, 1999, : 399 - 401
  • [29] Lightweight ironless-stator PM generators for direct-drive wind turbines
    Spooner, E
    Gordon, P
    Bumby, JR
    French, CD
    IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2005, 152 (01): : 17 - 26
  • [30] Design Challenges of Direct-Drive Permanent Magnet Superconducting Wind Turbine Generators
    Liu, Dong
    Song, Xiaowei
    Wang, Xuezhou
    2020 INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES (ICEM), VOL 1, 2020, : 640 - 646