Speech Quality Perception in Unilateral Cochlear Implant Users With Single-Sided Deafness

被引:0
|
作者
Kelly, Scott [1 ]
Kuhlmey, Megan E. [1 ]
Despotidis, Meghan A. [1 ]
Alter, Isaac L. [1 ]
Hwa, Tiffany P. [2 ]
Chern, Alexander [3 ]
Lalwani, Anil K. [1 ,4 ]
机构
[1] Columbia Univ, Vagelos Coll Phys & Surg, New York Presbyterian, Dept Otolaryngol Head & Neck Surg,Irving Med Ctr, 180 Ft Washington Ave,HP8, New York, NY 10032 USA
[2] Univ Penn, Perelman Sch Med, Dept Otorhinolaryngol, Philadelphia, PA USA
[3] Johns Hopkins Univ, Dept Otolaryngol Head & Neck Surg, Baltimore, MD USA
[4] Columbia Univ, Dept Mech Engn, New York, NY 10032 USA
关键词
cochlear implant; CSQI; hearing loss; single-sided deafness; speech quality perception; MUSIC PERCEPTION; 2; EARS; IDENTIFICATION; RECOGNITION; VALIDATION; ABILITIES; FREQUENCY; APPRAISAL; PROSODY; FUSION;
D O I
10.1002/ohn.941
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Objective. Cochlear implant (CI) users frequently complain about speech quality perception (SQP). In patients undergoing cochlear implantation for single-sided deafness, there is concern that poor SQP from the implanted ear will negatively impact binaural (CI + normal hearing [NH]) SQP. In this study, we investigate if binaural SQP is measurably different than unimplanted NH alone. Study Design. Cross-sectional study. Setting. Tertiary care center. Methods. Fifteen unilateral CI users with NH in the contralateral ear completed the validated Columbia Speech Quality Instrument. This instrument consists of 9 audio clips rated across 14 specific speech qualities using a 10-point visual analog scale. SQP was assessed in 3 conditions: CI only, NH only, and CI + NH. Results. Median speech quality scores were worse in the CI only condition compared to the NH only (50.0 vs 72.6, P = .0003) and binaural (50.0 vs 71.0, P = .007) conditions. Median speech quality scores were not significantly different between the NH only and binaural conditions (72.6 vs 71, P = .8). Compared to NH, CI speech quality sounded less clear, less natural, and more mechanical. Conclusion. Compared to NH, SQP is poorer with a CI alone. However, in contrast to expectation, there is no significant difference between NH and binaural SQP. This suggests poorer CI speech perception does not negatively impact binaural SQP in patients undergoing cochlear implantation for single-sided deafness.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Impact of Reverberation on Speech Perception and Sound Localization Accuracy in Cochlear Implant Users With Single-Sided Deafness
    Koertje, Monika
    Eichenauer, Anja
    Stoever, Timo
    Baumann, Uwe
    Weissgerber, Tobias
    OTOLOGY & NEUROTOLOGY, 2022, 43 (01) : E30 - E37
  • [2] Masked Speech Recognition as a Function of Masker Location for Cochlear Implant Users With Single-Sided Deafness
    Anderson, Kelly M.
    Buss, Emily
    Rooth, Meredith A.
    Richter, Margaret E.
    Overton, Andrea B.
    Brown, Kevin D.
    Dillon, Margaret T.
    AMERICAN JOURNAL OF AUDIOLOGY, 2022, 31 (03) : 757 - 763
  • [3] Acoustic Hearing Can Interfere With Single-Sided Deafness Cochlear-Implant Speech Perception
    Bernstein, Joshua G. W.
    Stakhovskaya, Olga A.
    Jensen, Kenneth Kragh
    Goupell, Matthew J.
    EAR AND HEARING, 2020, 41 (04): : 747 - 761
  • [4] Impact of Duration of Deafness on Speech Perception in Single-Sided Deafness Cochlear Implantation in Adults
    Nassiri, Ashley M.
    Wallerius, Katherine P.
    Saoji, Aniket A.
    Neff, Brian A.
    Driscoll, Colin L. W.
    Carlson, Matthew L.
    OTOLOGY & NEUROTOLOGY, 2022, 43 (01) : E45 - E49
  • [5] Restoration of spatial hearing in adult cochlear implant users with single-sided deafness
    Litovsky, Ruth Y.
    Moua, Keng
    Godar, Shelly
    Kan, Alan
    Misurelli, Sara M.
    Lee, Daniel J.
    HEARING RESEARCH, 2019, 372 : 69 - 79
  • [6] Children With Single-Sided Deafness Use Their Cochlear Implant
    Polonenko, Melissa Jane
    Papsin, Blake Croll
    Gordon, Karen Ann
    EAR AND HEARING, 2017, 38 (06): : 681 - 689
  • [7] Cochlear implantation in single-sided deafness for enhancement of sound localization and speech perception
    Kamal, Sally M.
    Robinson, Aaron D.
    Diaz, Rodney C.
    CURRENT OPINION IN OTOLARYNGOLOGY & HEAD AND NECK SURGERY, 2012, 20 (05): : 393 - 397
  • [8] The Sound of a Cochlear Implant Investigated in Patients With Single-Sided Deafness and a Cochlear Implant
    Peters, Jeroen P. M.
    Wendrich, Anne W.
    van Eijl, Ruben H. M.
    Rhebergen, Koenraad S.
    Versnel, Huib
    Grolman, Wilko
    OTOLOGY & NEUROTOLOGY, 2018, 39 (06) : 707 - 714
  • [9] The impact of cochlear implant microphone settings on the binaural hearing of experienced cochlear implant users with single-sided deafness
    Kurz, Anja
    Zanzinger, Maren
    Hagen, Rudolf
    Rak, Kristen
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2021, 278 (06) : 2067 - 2077
  • [10] Searching for the Sound of a Cochlear Implant: Evaluation of Different Vocoder Parameters by Cochlear Implant Users With Single-Sided Deafness
    Karoui, Chadlia
    James, Chris
    Barone, Pascal
    Bakhos, David
    Marx, Mathieu
    Macherey, Olivier
    TRENDS IN HEARING, 2019, 23