Electrochemical Behavior of Finasteride on Glassy Carbon Electrode Using Differential Pulse Voltammetric Technique

被引:0
|
作者
Hasan, Mohammed Q. [1 ]
Al-Taee, Amer T. [1 ]
Al-Imam, Mohammed M. A. [2 ]
机构
[1] Univ Mosul, Coll Sci, Chem Dept, Mosul, Iraq
[2] Univ Mosul, Coll Educ & Pure Sci, Chem Dept, Mosul, Iraq
来源
关键词
- Finasteride drug; Glassy carbon; Indirect determination; Differential pulse voltammetry;
D O I
10.22034/abec.2024.715425
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
The direct and indirect electrochemical behavior of finasteride was studied using a differential pulse technique coupled with a three-electrode detection system consisting of 2 mm diameter glassy carbon as a working electrode, 2 mm diameter platinum wire as an auxiliary electrode, and silver/silver chloride saturated potassium chloride as reference electrode (Ag/AgCl sat KCl). The finasteride gives a weak reduction peak at -0.68 V. The calibration curve of finasteride was constructed using Briton- Robinson buffer solution (pH = 3), the plot of reduction peak current and concentration gives a linear relationship within the concentration range of 0.999x10-5-19.607x10-5 M, with a correlation coefficient of 0.9903. To increase the sensitivity of the method, an indirect determination of finasteride through its interaction with cupric ion was investigated in acetate buffer solution (pH=2) and followed the decrease in reduction peak current of cupric ion as a result of adding sequence addition of finasteride solution. The calibration curve for finasteride was also constructed for its interaction with cupric ions by measuring the decrease of cupric reduction peak current with the sequence additions of finasteride. The calibration curve was linear within the concentration range of in tablets.
引用
收藏
页码:752 / 763
页数:12
相关论文
共 50 条
  • [1] A differential pulse voltammetric determination of nisoldipine using glassy carbon electrode in pharmaceutical preparations
    Dogrukol-Ak, D
    Gökören, N
    Tunçel, M
    ANALYTICAL LETTERS, 1998, 31 (01) : 105 - 116
  • [2] DIFFERENTIAL PULSE VOLTAMMETRIC DETERMINATION OF ROSUVASTATIN VIA GLASSY CARBON ELECTRODE
    Karadurmus, Leyla
    Kurbanoglu, Sevinc
    Uslu, Bengi
    Ozkan, Sibel A.
    REVUE ROUMAINE DE CHIMIE, 2017, 62 (6-7) : 579 - 586
  • [3] Electrochemical study and differential pulse voltammetric determination of oxcarbazepine and its main metabolite at a glassy carbon electrode
    Abolhasani, Jafar
    Hosseini, Hadi
    Khanmiri, Rahim Hosseinzadeh
    ANALYTICAL METHODS, 2014, 6 (03) : 850 - 856
  • [4] Electrochemical behavior and differential pulse voltammetric determination of paracetamol at a carbon ionic liquid electrode
    Xiaodong ShangGuan
    Hongfang Zhang
    Jianbin Zheng
    Analytical and Bioanalytical Chemistry, 2008, 391 : 1049 - 1055
  • [5] Electrochemical behavior and differential pulse voltammetric determination of paracetamol at a carbon ionic liquid electrode
    ShangGuan, Xiaodong
    Zhang, Hongfang
    Zheng, Jianbin
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2008, 391 (03) : 1049 - 1055
  • [6] Differential Pulse Voltammetric Method for Determination of Acemetacin in Pharmaceutical Formulation using Glassy Carbon Electrode
    Moaaz, Eman M.
    Fayed, Ahmed S.
    Rezk, Mamdouh R.
    Abdel-Moety, Ezzat M.
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2021, 13 (03): : 358 - 370
  • [7] ANODIC DIFFERENTIAL PULSE VOLTAMMETRIC DETERMINATION OF ESTROGENS ON A GLASSY-CARBON ELECTRODE
    DENG, JQ
    ZHANG, Z
    ACTA CHIMICA SINICA, 1984, 42 (12) : 1262 - 1265
  • [8] Differential pulse voltammetric determination of the dopaminergic agonist bromocriptine at glassy carbon electrode
    Radi, A
    El-Shahawi, MS
    Elmogy, T
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 37 (01) : 195 - 198
  • [9] DIFFERENTIAL PULSE VOLTAMMETRIC DETERMINATION OF TRACE SILICON AT A GLASSY-CARBON ELECTRODE
    WANG, EK
    WANG, MX
    ANALYTICA CHIMICA ACTA, 1982, 144 (DEC) : 147 - 153
  • [10] Highly Selective Differential Pulse Voltammetric Determination of Uric Acid using Modified Glassy Carbon Electrode
    Movlaee, Kaveh
    Norouzi, Parviz
    Beitollahi, Hadi
    Rezapour, Morteza
    Larijani, Bagher
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (04): : 3241 - 3251