Differential pulse voltammetric determination of the dopaminergic agonist bromocriptine at glassy carbon electrode

被引:14
|
作者
Radi, A [1 ]
El-Shahawi, MS [1 ]
Elmogy, T [1 ]
机构
[1] Mansoura Univ, Dept Chem, Fac Sci, Dumyat 34517, Egypt
关键词
bromocriptine; differential pulse voltammetry; glassy carbon electrode; electrochemical oxidation; pharmaceutical analysis;
D O I
10.1016/j.jpba.2004.10.013
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electrochemical oxidation of bromocriptine at glassy carbon electrode has been carried out in Britton-Robinson (B-R) buffer solutions in the pH range 2.0-11.0 employing cyclic, linear sweep and differential pulse voltammetry (DPV). Bromocriptine showed one well-defined oxidation peak accompanied by a smaller one. The oxidation process was found irreversible. For analytical purposes, the well-resolved diffusion controlled voltammetric peak at pH 5 was critically investigated. The linear relationship between peak current height and bromocriptine concentration allowed the differential pulse voltammetric determination of the drug over a wide concentration range, from 0.04 to 5.00 mug ml(-1) with a detection limit of 0.01 mug ml(-1). A relative standard deviation of 1.44% at 0. 1 mug ml(-1) level was obtained. The proposed DPV method was successfully applied for the individual tablet assay to verify the uniformity content of bromocriptine in commercial tablets. (C) 2004 Published by Elsevier B.V.
引用
收藏
页码:195 / 198
页数:4
相关论文
共 50 条
  • [1] DIFFERENTIAL PULSE VOLTAMMETRIC DETERMINATION OF ROSUVASTATIN VIA GLASSY CARBON ELECTRODE
    Karadurmus, Leyla
    Kurbanoglu, Sevinc
    Uslu, Bengi
    Ozkan, Sibel A.
    [J]. REVUE ROUMAINE DE CHIMIE, 2017, 62 (6-7) : 579 - 586
  • [2] ANODIC DIFFERENTIAL PULSE VOLTAMMETRIC DETERMINATION OF ESTROGENS ON A GLASSY-CARBON ELECTRODE
    DENG, JQ
    ZHANG, Z
    [J]. ACTA CHIMICA SINICA, 1984, 42 (12) : 1262 - 1265
  • [3] DIFFERENTIAL PULSE VOLTAMMETRIC DETERMINATION OF TRACE SILICON AT A GLASSY-CARBON ELECTRODE
    WANG, EK
    WANG, MX
    [J]. ANALYTICA CHIMICA ACTA, 1982, 144 (DEC) : 147 - 153
  • [4] A differential pulse voltammetric determination of nisoldipine using glassy carbon electrode in pharmaceutical preparations
    Dogrukol-Ak, D
    Gökören, N
    Tunçel, M
    [J]. ANALYTICAL LETTERS, 1998, 31 (01) : 105 - 116
  • [5] A new differential pulse voltammetric method for the determination of nitrate at a copper plated glassy carbon electrode
    Solak, AO
    Gülser, P
    Gökmese, E
    Gökmese, F
    [J]. MIKROCHIMICA ACTA, 2000, 134 (1-2) : 77 - 82
  • [6] A New Differential Pulse Voltammetric Method for the Determination of Nitrate at a Copper Plated Glassy Carbon Electrode
    Ali Osman Solak
    Pınar Gülser
    Ebru Gökm
    Faruk Gökmesşe
    [J]. Microchimica Acta, 2000, 134 : 77 - 82
  • [7] Differential Pulse Voltammetric Method for Determination of Acemetacin in Pharmaceutical Formulation using Glassy Carbon Electrode
    Moaaz, Eman M.
    Fayed, Ahmed S.
    Rezk, Mamdouh R.
    Abdel-Moety, Ezzat M.
    [J]. ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2021, 13 (03): : 358 - 370
  • [8] Rapid Differential Pulse Voltammetric Determination of Galantamine on the Simple Glassy Carbon Electrode; Alternative for the Standard Methods
    Islamnezhad, Akbar
    Mofidi, Jamshid
    Madahi, Hamed
    Mohammadi, Kamal
    [J]. ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2013, 5 (02): : 255 - 264
  • [9] Highly Selective Differential Pulse Voltammetric Determination of Uric Acid using Modified Glassy Carbon Electrode
    Movlaee, Kaveh
    Norouzi, Parviz
    Beitollahi, Hadi
    Rezapour, Morteza
    Larijani, Bagher
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (04): : 3241 - 3251
  • [10] Electrochemical study and differential pulse voltammetric determination of oxcarbazepine and its main metabolite at a glassy carbon electrode
    Abolhasani, Jafar
    Hosseini, Hadi
    Khanmiri, Rahim Hosseinzadeh
    [J]. ANALYTICAL METHODS, 2014, 6 (03) : 850 - 856