Quantifying Distal Deltoid Disruption With Linear versus Curvilinear Plating of Proximal Humerus Fractures: A Cadaveric Study

被引:0
|
作者
Galal, Youssef [1 ]
Vohra, Arjun [1 ]
Saunders, Patrick [1 ]
Paul, Ben [1 ,2 ]
Hui, Clayton [1 ]
Yao, Stephen [1 ]
Lederman, Evan [1 ]
Mckee, Michael [1 ]
Shah, Anup [1 ]
机构
[1] Univ Arizona, Banner Univ Med Grp, Coll Med, Phoenix, AZ USA
[2] Creighton Univ Hlth Sci Phoenix, Phoenix, AZ USA
关键词
open reduction; internal fixation; plate fixation; proximal humerus; deltoid; OPEN REDUCTION; INTERNAL-FIXATION; SHOULDER ARTHROPLASTY; LOCKED PLATE; CLASSIFICATION; EPIDEMIOLOGY; PART;
D O I
10.1097/BOT.0000000000002871
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BACKGROUND: Plate fixation of proximal humeral fractures is usually associated with some degree of distal deltoid dissection. The purpose of this study was to quantify deltoid release with standard linear versus curvilinear plates used in the repair of proximal humeral fractures. METHODS: Seven nonpaired, fresh-frozen, clavicle-to-fingertip cadaveric shoulders met the inclusion criteria for this study. Four different proximal humerus implants were tested. One of these plates was curvilinear (89 mm), and the other 3 plates were linear (85, 98, 109 mm in length). Plates were compared based on the amount of deltoid insertion released for proper plate positioning. An analysis of variance with post hoc Tukey tests was conducted to compare mean deltoid disruption across the 3 shortest plate types from each manufacturer. A linear regression analysis was conducted to analyze the effect of plate length on mean deltoid release. RESULTS: The mean deltoid insertion length was 39.6 +/- 8.6 mm (n = 7). The curvilinear plate (89 mm) required the least amount of average deltoid release at 4.1 +/- 4.5 mm, or 12.1% of the deltoid insertion. Independent analysis of variance, including the 3 shortest plates from each manufacturer, found a significant effect of which plate was used on the amount of deltoid disruption that resulted (F(2, 18) = 18.0, P < 0.001, omega = 0.6). A linear regression including all 4 plates demonstrated a statistically significant direct relationship between the plate length and the mean deltoid released (y = 0.6x - 43.8, r(2) = 4). CONCLUSION: This study demonstrates that proximal humerus plate length has a direct relationship with the amount of deltoid released during plating. Although deltoid disruption is length dependent, plate shape (curvilinear vs. linear) could also be contributory. When comparing a curvilinear and a linear plate of similar lengths, the curvilinear plate resulted in less mean deltoid release.
引用
收藏
页码:566 / 570
页数:5
相关论文
共 50 条
  • [41] Radiographic and clinical comparisons of distal tibia shaft fractures (4 to 11 cm proximal to the plafond): Plating versus intramedullary nailing
    Vallier, Heather A.
    Le, T. Toan
    Bedi, Asheesh
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (05) : 307 - 311
  • [42] Comparative study of perpendicular versus parallel double plating methods for type C distal humeral fractures
    Lan Xia
    Zhang Li-hai
    Tao Sheng
    Zhang Qun
    Liang Xiang-dang
    Yuan Bang-tuo
    Xu Wen-peng
    Yin Peng
    Tang Pei-fu
    CHINESE MEDICAL JOURNAL, 2013, 126 (12) : 2337 - 2342
  • [43] Nailing versus plating for comminuted fractures of the distal femur: a comparative biomechanical in vitro study of three implants
    I. Mehling
    P. Hoehle
    W. Sternstein
    J. Blum
    P. M. Rommens
    European Journal of Trauma and Emergency Surgery, 2013, 39 : 139 - 146
  • [44] Comparative study of perpendicular versus parallel double plating methods for type C distal humeral fractures
    LAN Xia
    ZHANG Li-hai
    TAO Sheng
    ZHANG Qun
    LIANG Xiang-dang
    YUAN Bang-tuo
    XU Wen-peng
    YIN Peng
    TANG Pei-fu
    中华医学杂志(英文版), 2013, 126 (12) : 2337 - 2342
  • [45] Medial helical versus straight lateral plating of distal femoral fractures-a biomechanical comparative study
    Pastor, Torsten
    Zderic, Ivan
    Souleiman, Firas
    Drenchev, Ludmil
    Skulev, Hristo Kostov
    Berk, Till
    Gueorguiev, Boyko
    Knobe, Matthias
    CLINICAL BIOMECHANICS, 2023, 110
  • [46] Nailing versus plating for comminuted fractures of the distal femur: a comparative biomechanical in vitro study of three implants
    Mehling, I.
    Hoehle, P.
    Sternstein, W.
    Blum, J.
    Rommens, P. M.
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2013, 39 (02) : 139 - 146
  • [47] Intramedullary nailing versus percutaneous locked plating of distal extra-articular tibial fractures: A retrospective study
    Seyhan M.
    Unay K.
    Sener N.
    European Journal of Orthopaedic Surgery & Traumatology, 2013, 23 (5) : 595 - 601
  • [48] Comparative clinical study of locking screws versus smooth locking pegs in volar plating of distal radius fractures
    Boretto, J. G.
    Pacher, N.
    Giunta, D.
    Gallucci, G. L.
    Alfie, V.
    De Carli, P.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2014, 39 (07) : 755 - 760
  • [49] Position of polyaxial versus monoaxial screws in locked plating for proximal humeral fractures: Analysis of a prospective randomized study
    Ockert B.
    Pedersen V.
    Geyer L.
    Wirth S.
    Mutschler W.
    Grote S.
    European Journal of Orthopaedic Surgery & Traumatology, 2014, 24 (5) : 747 - 752
  • [50] Intramedullary fixation of proximal humerus fractures: do locking bolts endanger the axillary nerve or the ascending branch of the anterior circumflex artery? A cadaveric study
    Nijs, Stefaan
    Sermon, An
    Broos, Paul
    PATIENT SAFETY IN SURGERY, 2008, 2