Quantifying Distal Deltoid Disruption With Linear versus Curvilinear Plating of Proximal Humerus Fractures: A Cadaveric Study

被引:0
|
作者
Galal, Youssef [1 ]
Vohra, Arjun [1 ]
Saunders, Patrick [1 ]
Paul, Ben [1 ,2 ]
Hui, Clayton [1 ]
Yao, Stephen [1 ]
Lederman, Evan [1 ]
Mckee, Michael [1 ]
Shah, Anup [1 ]
机构
[1] Univ Arizona, Banner Univ Med Grp, Coll Med, Phoenix, AZ USA
[2] Creighton Univ Hlth Sci Phoenix, Phoenix, AZ USA
关键词
open reduction; internal fixation; plate fixation; proximal humerus; deltoid; OPEN REDUCTION; INTERNAL-FIXATION; SHOULDER ARTHROPLASTY; LOCKED PLATE; CLASSIFICATION; EPIDEMIOLOGY; PART;
D O I
10.1097/BOT.0000000000002871
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BACKGROUND: Plate fixation of proximal humeral fractures is usually associated with some degree of distal deltoid dissection. The purpose of this study was to quantify deltoid release with standard linear versus curvilinear plates used in the repair of proximal humeral fractures. METHODS: Seven nonpaired, fresh-frozen, clavicle-to-fingertip cadaveric shoulders met the inclusion criteria for this study. Four different proximal humerus implants were tested. One of these plates was curvilinear (89 mm), and the other 3 plates were linear (85, 98, 109 mm in length). Plates were compared based on the amount of deltoid insertion released for proper plate positioning. An analysis of variance with post hoc Tukey tests was conducted to compare mean deltoid disruption across the 3 shortest plate types from each manufacturer. A linear regression analysis was conducted to analyze the effect of plate length on mean deltoid release. RESULTS: The mean deltoid insertion length was 39.6 +/- 8.6 mm (n = 7). The curvilinear plate (89 mm) required the least amount of average deltoid release at 4.1 +/- 4.5 mm, or 12.1% of the deltoid insertion. Independent analysis of variance, including the 3 shortest plates from each manufacturer, found a significant effect of which plate was used on the amount of deltoid disruption that resulted (F(2, 18) = 18.0, P < 0.001, omega = 0.6). A linear regression including all 4 plates demonstrated a statistically significant direct relationship between the plate length and the mean deltoid released (y = 0.6x - 43.8, r(2) = 4). CONCLUSION: This study demonstrates that proximal humerus plate length has a direct relationship with the amount of deltoid released during plating. Although deltoid disruption is length dependent, plate shape (curvilinear vs. linear) could also be contributory. When comparing a curvilinear and a linear plate of similar lengths, the curvilinear plate resulted in less mean deltoid release.
引用
收藏
页码:566 / 570
页数:5
相关论文
共 50 条
  • [1] Parallel Versus Orthogonal Plating for Distal Humerus Fractures
    Vennettilli, Marco
    Athwal, George S.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2012, 37A (04): : 819 - 820
  • [2] A cadaveric study on the anatomy of the deltoid insertion and its relationship to the deltopectoral approach to the proximal humerus
    Klepps, S
    Auerbach, J
    Calhon, O
    Ceemon, E
    Flatow, E
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2004, 13 (03) : 322 - 327
  • [3] Intra-articular Distal Humerus Fractures: Parallel Versus Orthogonal Plating
    Haglin, Jack M.
    Kugelman, David N.
    Lott, Ariana
    Belayneh, Rebekah
    Konda, Sanjit R.
    Egol, Kenneth A.
    HSS JOURNAL, 2022, 18 (02) : 256 - 263
  • [4] Complex Proximal Humerus Fractures Treated With Locked Plating Utilizing an Extended Deltoid Split Approach With a Shoulder Strap Incision
    Gavaskar, Ashok S.
    Chowdary, Naveen
    Abraham, Samson
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2013, 27 (02) : 73 - 76
  • [5] How to Use Fluoroscopic Imaging to Prevent Intraarticular Screw Perforation During Locked Plating of Proximal Humerus Fractures: A Cadaveric Study
    Lowe, Jason B.
    Monazzam, Shafagh
    Walton, Blaine
    Nelson, Elisha
    Wolinsky, Philip R.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2015, 29 (10) : e401 - e407
  • [6] Minimally invasive lateral plating for diaphyseal fractures with extension into the proximal humerus and its implications for the deltoid muscle and its distal insertion: functional analysis and MR-imaging
    D Flury
    C Metzler
    S Rauch
    M Schläppi
    E Benninger
    C Meier
    BMC Musculoskeletal Disorders, 24
  • [7] Minimally invasive lateral plating for diaphyseal fractures with extension into the proximal humerus and its implications for the deltoid muscle and its distal insertion: functional analysis and MR-imaging
    Flury, D.
    Metzler, C.
    Rauch, S.
    Schlaeppi, M.
    Benninger, E.
    Meier, C.
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [8] Nailing versus plating in humerus shaft fractures: A prospective comparative study
    Kiran Singisetti
    M. Ambedkar
    International Orthopaedics, 2010, 34 : 571 - 576
  • [9] Nailing versus plating in humerus shaft fractures: A prospective comparative study
    Singisetti, Kiran
    Ambedkar, M.
    INTERNATIONAL ORTHOPAEDICS, 2010, 34 (04) : 571 - 576
  • [10] Biomechanical comparison of orthogonal versus parallel double plating systems in intraarticular distal humerus fractures
    Atalar, Ata C.
    Tunali, Onur
    Ersen, Ali
    Kapicioglu, Mehmet
    Saglam, Yavuz
    Demirhan, Mehmet S.
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2017, 51 (01) : 23 - 28