A novel method to obtain the characteristic constant of a measurement chain

被引:0
|
作者
Yang, Jing [1 ,2 ]
Cui, Zhitong [2 ]
Cao, Fei [1 ]
Zhu, Zhizhen [2 ]
Dong, Yayun [2 ]
Qiu, Mengtong [2 ]
机构
[1] Xian Res Inst High Technol, Xian, Peoples R China
[2] Northwest Inst Nucl Technol, Xian, Peoples R China
关键词
characteristic constant; calibration waveform; high-altitude electromagnetic pulse (HEMP); measurement chain; proportional sensor; wideband EM sensor;
D O I
10.1088/1361-6501/ad64f6
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The characteristic constant is commonly used to reconstruct the measured signal when a measurement chain with flat wideband frequency response is applied. The characteristic constant is often calibrated by a standard pulse that follows a rectangular pulse behavior. However, a pulse that is more than similar to the measured signal is more suitable theoretically than a rectangular pulse as the calibration waveform. To reduce the measurement error caused by the calibration waveform, a novel method to optimize the calibration waveform is proposed in this paper. A dataset is constructed based on the prior information of the signal to be measured. Criterions for better calibration waveforms are also discussed. Dataset construction along with this criterion makes the calibration waveform optimization a solvable mathematical problem. The calibration waveform can then be quantitively evaluation and optimized. The optimized calibration waveform will make the error caused by the fluctuations in the frequency response of a proportional sensor as small as possible statistically. As an actual application case, simulation results are also provided to intuitively explain the method. The procedure to obtain the characteristic constant based on the optimized calibration waveform is then outlined. A calibration system for the given application case is built. Finally, an experiment is designed and executed. The experimental results approved the method proposed in this paper well.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] IMPEDANCE TUBE MEASUREMENT OF PROPAGATION CONSTANT AND CHARACTERISTIC IMPEDANCE OF POROUS ACOUSTICAL MATERIAL
    YANIV, SL
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1973, 54 (05): : 1138 - 1142
  • [22] MEASUREMENT OF THE CHARACTERISTIC IMPEDANCE AND PROPAGATION CONSTANT OF MATERIALS HAVING HIGH FLOW RESISTIVITY
    CHAMPOUX, Y
    STINSON, MR
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1991, 90 (04): : 2182 - 2191
  • [23] SOIL ROUGHNESS MEASUREMENT - CHAIN METHOD
    SALEH, A
    JOURNAL OF SOIL AND WATER CONSERVATION, 1993, 48 (06) : 527 - 529
  • [24] A Novel ICPT Compensation Topology with Excellent Constant Current Output Characteristic
    Yao, Yousu
    Guo, Weifeng
    Liu, Xiaosheng
    Wang, Yijie
    Xu, Dianguo
    2016 IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, DRIVES AND ENERGY SYSTEMS (PEDES), 2016,
  • [25] Sine sweeping constant current exciting for geophone characteristic parameter measurement and identification
    Zhang, Gaihui
    Hu, Shiyue
    Yingyong Lixue Xuebao/Chinese Journal of Applied Mechanics, 2006, 23 (03): : 427 - 430
  • [26] A new method to obtain the rotor time constant of induction motor based on vector control
    Tan, RM
    Qu, WL
    Zhang, X
    ICEMS'2001: PROCEEDINGS OF THE FIFTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS I AND II, 2001, : 47 - 50
  • [27] A Method to Obtain Constant Quality VBR Rate Control for H.264/SVC
    Pan, Jin-Feng
    Yu, Hong-Yang
    INTERNATIONAL CONFERENCE ON ELECTRONIC AND ELECTRICAL ENGINEERING (CEEE 2014), 2014, : 442 - 449
  • [28] A new method of birefringence measurement to obtain stress field using photoelasticity
    Gomi, K. (kenji@cck.dendai.ac.jp), CEO2, Tokyo Institue of Technology; CASIO Science Promotion Foundation; The Lao Foundation for Arts and Sciences (Inst. of Elec. and Elec. Eng. Computer Society, 445 Hoes Lane - P.O.Box 1331, Piscataway, NJ 08855-1331, United States):
  • [29] SOM+PSO A Novel Method to Obtain Classification Rules
    Lanzarini, Laura
    Monte, Augusto Villa
    Ronchetti, Franco
    JOURNAL OF COMPUTER SCIENCE & TECHNOLOGY, 2015, 15 (01): : 15 - 22
  • [30] A novel method to obtain microtensile specimens minimizing cut flaws
    Sadek, Fernanda Tranchesi
    Monticelli, Francesca
    Muench, Antonio
    Ferrari, Marco
    Cardoso, Paulo Eduardo Capel
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2006, 78B (01) : 7 - 14