A systematic comparison of four pharmacopoeial methods for measuring powder flowability

被引:4
|
作者
Tharanon, Weeraya [1 ]
Guo, Yiwang [2 ]
Peerapattana, Jomjai [1 ]
Sun, Changquan Calvin [2 ]
机构
[1] Khon Kaen Univ, Fac Pharmaceut Sci, Div Pharmaceut Technol, Khon Kaen 40002, Thailand
[2] Univ Minnesota, Coll Pharm, Dept Pharmaceut, Pharmaceut Mat Sci & Engn Lab, Minneapolis, MN 55455 USA
基金
美国国家科学基金会;
关键词
Powder flow; Angle of repose; Shear cell; Compressibility index; Hausner ratio; Flow through an orifice; FLOW PROPERTIES; REPOSE; ANGLE; TESTS;
D O I
10.1016/j.ijpharm.2024.124454
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Powder flow is one of the crucial factors affecting several pharmaceutical manufacturing processes. Problems due to insufficient powder flow reduce production process efficiency and cause suboptimum product quality. The U. S. Pharmacopoeia has specified four methods to evaluate the flowability of pharmaceutical powders, including angle of repose (AoR), compressibility index (CI) and Hausner ratio (HR), Flow through an orifice, and shear cell. Comparison within and between those methods with 21 powders (covering a wide range of flowability) was performed in this study. Strong correlation was observed between fixed base cone AoR, and fixed height cone AoR (R-2 = 0.939). CI and HR values calculated from a tapped density tester (meeting USP standards), manual tapping, and Geopyc (R) correlated strongly (R-2 > 0.9). AoR, CI/HR, minimum diameter for flowing through an orifice (dmin), and shear cell results generally correlate strongly for materials with flowability worse than Avicel (R) PH102. Both shear cell and CI/HR methods can reliably distinguish powders exhibiting poor flow. For materials with good flow, the ability to distinguish powders follows the order of AoR approximate to CI/HR > shear cell > dmin. The systematic comparison of the four common methods provides useful information to guide the selection of methods for future powder flow characterization. Given the limitations observed in all four methods, we recommend that multiple techniques should be used, when possible, to more holistically characterize the flowability of a wide range of powders.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Comparison of Four Methods for Measuring Heterophoria and Accommodative Convergence over Accommodation Ratio
    Nores-Palmas, Noelia
    Noya-Padin, Veronica
    Yebra-Pimentel, Eva
    Jesus Giraldez, Maria
    Pena-Verdeal, Hugo
    VISION, 2024, 8 (04)
  • [22] Comparison between a Uniaxial Compaction Tester and a Shear Tester for the Characterization of Powder Flowability
    Parrella, Luca
    Barletta, Diego
    Boerefijn, Renee
    Poletto, Massimo
    KONA POWDER AND PARTICLE JOURNAL, 2008, 26 (March) : 178 - 189
  • [23] Comparison of three rotational shear cell testers: Powder flowability and bulk density
    Koynov, Sara
    Glasser, Benjamin
    Muzzio, Fernando
    POWDER TECHNOLOGY, 2015, 283 : 103 - 112
  • [24] Flowability of steel and tool steel powders: A comparison between testing methods
    Marchetti, Lorenzo
    Hulme-Smith, Christopher
    POWDER TECHNOLOGY, 2021, 384 : 402 - 413
  • [25] Comparison of Four Different ppm-Level Methods for Traceability of HVDC Measuring Systems
    Meisner, J.
    Passon, S.
    Elg, A-P
    Koenig, K.
    Kraemer, J.
    Noertershaeuser, W.
    Rest
    Weinheimer, C.
    Winzen, D.
    PROCEEDINGS OF THE 21ST INTERNATIONAL SYMPOSIUM ON HIGH VOLTAGE ENGINEERING, VOL 2, 2020, 599 : 718 - 726
  • [26] Effects of formulation on flowability of selected herbal powders using compendial methods and powder flow analyser
    Etti, C. J.
    Yusof, Y. A.
    Chin, N. L.
    Tahir, Mohd S.
    INTERNATIONAL FOOD RESEARCH JOURNAL, 2016, 23 : S225 - S230
  • [27] A Comparison of Methods of Measuring Improvement
    McCraw, L. W.
    RESEARCH QUARTERLY, 1951, 22 (02): : 191 - 200
  • [28] Comparison of Methods for Measuring Cyclodeviation
    Liebermann, Laura
    Hatt, Sarah R.
    Leske, David A.
    Klaehn, Lindsay D.
    Kramer, Andrea M.
    Holmes, Jonathan M.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2021, 224 : 332 - 342
  • [29] STATISTICAL COMPARISON OF MEASURING METHODS
    CARTER, RL
    BIOMETRICS, 1978, 34 (03) : 531 - 531
  • [30] A comparison of powder particle size measuring instruments
    Iacocca, RG
    German, RM
    INTERNATIONAL JOURNAL OF POWDER METALLURGY, 1997, 33 (08): : 35 - 48