A systematic comparison of four pharmacopoeial methods for measuring powder flowability

被引:4
|
作者
Tharanon, Weeraya [1 ]
Guo, Yiwang [2 ]
Peerapattana, Jomjai [1 ]
Sun, Changquan Calvin [2 ]
机构
[1] Khon Kaen Univ, Fac Pharmaceut Sci, Div Pharmaceut Technol, Khon Kaen 40002, Thailand
[2] Univ Minnesota, Coll Pharm, Dept Pharmaceut, Pharmaceut Mat Sci & Engn Lab, Minneapolis, MN 55455 USA
基金
美国国家科学基金会;
关键词
Powder flow; Angle of repose; Shear cell; Compressibility index; Hausner ratio; Flow through an orifice; FLOW PROPERTIES; REPOSE; ANGLE; TESTS;
D O I
10.1016/j.ijpharm.2024.124454
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Powder flow is one of the crucial factors affecting several pharmaceutical manufacturing processes. Problems due to insufficient powder flow reduce production process efficiency and cause suboptimum product quality. The U. S. Pharmacopoeia has specified four methods to evaluate the flowability of pharmaceutical powders, including angle of repose (AoR), compressibility index (CI) and Hausner ratio (HR), Flow through an orifice, and shear cell. Comparison within and between those methods with 21 powders (covering a wide range of flowability) was performed in this study. Strong correlation was observed between fixed base cone AoR, and fixed height cone AoR (R-2 = 0.939). CI and HR values calculated from a tapped density tester (meeting USP standards), manual tapping, and Geopyc (R) correlated strongly (R-2 > 0.9). AoR, CI/HR, minimum diameter for flowing through an orifice (dmin), and shear cell results generally correlate strongly for materials with flowability worse than Avicel (R) PH102. Both shear cell and CI/HR methods can reliably distinguish powders exhibiting poor flow. For materials with good flow, the ability to distinguish powders follows the order of AoR approximate to CI/HR > shear cell > dmin. The systematic comparison of the four common methods provides useful information to guide the selection of methods for future powder flow characterization. Given the limitations observed in all four methods, we recommend that multiple techniques should be used, when possible, to more holistically characterize the flowability of a wide range of powders.
引用
收藏
页数:11
相关论文
共 50 条
  • [2] Measuring powder flowability: a comparison of test methods Part II
    Schulze, Dietmar
    Powder and Bulk Engineering, 1996, 10 (06):
  • [3] Measurement and evaluation methods of powder characteristics and flowability
    Cong Xiaomin
    Gai Guosheng
    Feng Tao
    Weng Duan
    Dong Qingyun
    Huang Mingjun
    7th International Conference on Measurement and Control of Granular Materials, Proceedings, 2006, : 23 - 27
  • [4] Review of the flowability measuring techniques for powder metallurgy industry
    Kulkarni, P. A.
    Berry, R. J.
    Bradley, M. S. A.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, 2010, 224 (E3) : 159 - 168
  • [5] Comparison of four methods for measuring total suction
    Agus, SS
    Schanz, T
    VADOSE ZONE JOURNAL, 2005, 4 (04) : 1087 - 1095
  • [6] Comparison of two powder conditioning methods to improve UO2 powder flowability for press die filling
    Beaunac, E.
    Leturia, M.
    Robisson, A. -C.
    Ablitzer, C.
    Saleh, K.
    POWDER TECHNOLOGY, 2022, 395 : 1 - 13
  • [7] Measuring powder flowability with a modified Warren Spring cohesion tester
    Mohammed, Salam A.
    Abdullah, Ezzat C.
    Geldart, Derek
    Raman, Abdul Aziz A.
    PARTICUOLOGY, 2011, 9 (02) : 148 - 154
  • [8] Measuring powder flowability with a modified Warren Spring cohesion tester
    Salam A.Mohammed
    Ezzat C.Abdullah
    Derek Geldart
    Abdul Aziz A.Raman
    Particuology, 2011, 9 (02) : 148 - 154
  • [9] A comparison of four methods of measuring gross phosphorus mineralization
    Kellogg, Laurie E.
    Bridgham, Scott D.
    Lopez-Hernandez, Danilo
    SOIL SCIENCE SOCIETY OF AMERICA JOURNAL, 2006, 70 (04) : 1349 - 1358
  • [10] A comparison of four in vivo methods of measuring tibial torsion
    Milner, CE
    Soames, RW
    JOURNAL OF ANATOMY, 1998, 193 : 139 - 144